Recovery dynamics of multifocal pupillographic objective perimetry from tropicamide dilation

被引:4
|
作者
Rai, Bhim Bahadur [1 ]
Sabeti, Faran [1 ,2 ]
Carle, Corinne F. [1 ,3 ]
Rohan, Emilie M. F. [1 ]
Sarac, Ozge [1 ,4 ]
van Kleef, Joshua [1 ]
Maddess, Ted [1 ]
机构
[1] Australian Natl Univ, John Curtin Sch Med Res, Div Neurosci, Bldg 131 Garran Rd, Canberra, ACT 2601, Australia
[2] Univ Canberra, Sch Optometry, Bruce, ACT, Australia
[3] Australian Natl Univ, ANU Med Sch, Canberra, ACT, Australia
[4] Yildirim Beyazit Univ, Ankara Ataturk Training & Res Hosp, Dept Ophthalmol, Ankara, Turkey
基金
澳大利亚研究理事会;
关键词
Anisocoria; Multifocal; Objective perimetry; Pupillography; Rebound miosis; Tropicamide; CONTRACTION ANISOCORIA; PUPILLARY RESPONSE; GANGLION-CELLS; PRIMATE RETINA; LUMINANCE; COLOR; LIGHT; INSTILLATION; TOPOGRAPHY; STIMULI;
D O I
10.1007/s00417-019-04523-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To study the pupillary system by combining mydriasis and multifocal pupillographic objective perimetry (mfPOP). In particular, we explored how the dynamics of recovery differ for concurrently measured direct and consensual sensitivity, response delay, and signal-to-noise ratios (SNRs) for binocular mydriasis. Methods We recruited 26 normal participants, all with brown irides. The dichoptic mfPOP stimuli concurrently assessed 44-region/eye and both pupils. Two pre-dilation tests were followed by pairs of repeated tests at 1, 2, 4, 6, 8, 12, 24, and 48 h following dilation of both pupils with 1% tropicamide. Three subjects were retested with only the right pupil dilated. Linear models determined the independent effects of mydriasis upon the per-region and pupil measures over time. Results Post-dilation, the per-region delays initially decreased by 16.3 +/- 6.02 ms (mean +/- SE) (p < 0.0001, cf. baseline of 471.1 +/- 4.36 ms), then increased to slower than baseline by 17.42 +/- 5.57 ms after 4 h (p < 0.002), recovering to baseline at 8 h. By comparison, per-region sensitivities (constriction amplitudes) were still reduced by - 6.20 +/- 0.70 mu m at 8 h (p < 0.0001, cf. baseline of 21.1 +/- 0.55 mu m), recovered at 24 h, but rebounded at 48 h (p = 0.005). The SNRs for sensitivities and delays both recovered by 8-12 h. Across all the data, sensitivities reduced by 2.67 +/- 0.25 mu m/decade of age, and delay increased by 15.4 +/- 1.98 ms/decade (both p < 0.00001). Data from 3 of the 26 subjects who repeated the testing for monocular dilation found that consensual response sensitivities were larger than direct for 8 h (p < 0.018). Conclusions The per-region sensitivities were affected for longer than SNRs or delays. Strong early SNRs indicated proportionately lower pupil noise for larger pupil diameters. Following mydriasis with tropicamide 1%, the constriction amplitude measurements with mfPOP should be considered only after 48 h, but time-to-peak can be measured after 8-12 h.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 50 条
  • [31] Comparison of objective tests in glaucoma - Multifocal objective perimetry and Heidelberg Retinal Tomography
    Graham, SL
    Klistorner, A
    Balachandran, C
    Goldberg, I
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U493 - U493
  • [32] Diagnostic power of rapid multifocal objective perimetry in Alzheimer's
    Maddess, Ted
    Rohan, Emilie Marie Francoise
    Kulh, Mary Ann
    van Kleef, Joshua
    Rai, Bhim Bahadur
    Carle, Corinne
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [33] Multifocal objective perimetry compared with Humphrey full-threshold perimetry in patients with optic neuritis
    Pakrou, Nima
    Casson, Robert
    Kaines, Andrew
    Selva, Dinesh
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (06): : 562 - 567
  • [34] A new method of multifocal objective VEP perimetry for glaucoma detection.
    Graham, SL
    Klistorner, AI
    Goldberg, I
    Billson, FC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S314 - S314
  • [35] Chromatic multifocal pupilloperimetry for objective perimetry in retinal and optic nerve neurodegeneration
    Sher-Rosenthal, Ifat
    Gurevich, Maya
    Rotenstreich, Ygal
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [36] THE EFFECT OF IRIS COLOUR ON PUPIL RESPONSE WITH MULTIFOCAL PUPIL OBJECTIVE PERIMETRY
    Kolic, Maria
    James, Andrew
    Essex, Rohan
    Maddess, Ted
    Carle, Corinne
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 135 - 135
  • [37] Application of multifocal VEP objective perimetry to glaucoma management - Clinical experience
    Graham, SL
    Klistorner, A
    Goldberg, I
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U781 - U781
  • [38] Chromatic Multifocal Pupillometer for Objective Perimetry and Diagnosis of Patients with Retinitis Pigmentosa
    Chibel, Ron
    Sher, Ifat
    Ben Ner, Daniel
    Mhajna, Mohamad O.
    Achiron, Asaf
    Hajyahia, Soad
    Skaat, Alon
    Berchenko, Yakir
    Oberman, Bernice
    Kalter-Leibovici, Ofra
    Freedman, Laurence
    Rotenstreich, Ygal
    OPHTHALMOLOGY, 2016, 123 (09) : 1898 - 1911
  • [39] Effect of pupil size on objective perimetry using multifocal visual evoked potentials
    Martins, A
    Balachandran, C
    Klistorner, A
    Graham, SL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U446 - U446
  • [40] Clinical application of objective perimetry using multifocal visual evoked potentials in glaucoma practice
    Graham, SL
    Klistorner, AI
    Goldberg, I
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (06) : 729 - 739