A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals

被引:7
|
作者
Sousa-Neto, Manoel Damiao [1 ]
Crozeta, Bruno Monguilhott [1 ]
Lopes, Fabiane Carneiro [1 ]
Mazzi-Chaves, Jardel Francisco [1 ]
Pereira, Rodrigo Dantas [1 ]
Silva-Sousa, Alice Correa [1 ]
de Andrade Amaral, Mariana Carvalho [2 ]
Steier, Liviu [3 ]
Jacobs, Reinhilde [4 ]
Correa Silva-Sousa, Yara Teresinha [2 ]
机构
[1] Univ Sao Paulo, Sch Dent Ribeirao Preto, Dept Restorat Dent, Ribeirao Preto, SP, Brazil
[2] Univ Ribeirao Preto UNAERP, Fac Dent, Ribeirao Preto, SP, Brazil
[3] Univ Penn UPenn, Sch Dent Med, Philadelphia, PA USA
[4] Katholieke Univ Leuven KU Leuven, Fac Med, Dept Imaging & Pathol, Leuven, Belgium
来源
BRAZILIAN ORAL RESEARCH | 2020年 / 34卷
基金
巴西圣保罗研究基金会;
关键词
APICALLY EXTRUDED DEBRIS; GEOMETRY; INSTRUMENTATION; TRANSPORTATION; MORPHOLOGY; ONESHAPE;
D O I
10.1590/1807-3107bor-2020.vol34.0039
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 mu m anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (alpha = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 +/- 0.05 mm) compared to coronal (0.08 +/- 0.040 mm) and middle (0.07 +/- 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 +/- 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Micro-computed Evaluation of Canal Transportation and Centering Ability of 5 Rotary and Reciprocating Systems with Different Metallurgical Properties and Surface Treatments in Curved Root Canals
    Kabil, Emina
    Katic, Marko
    Anic, Ivica
    Bago, Ivona
    JOURNAL OF ENDODONTICS, 2021, 47 (03) : 477 - 484
  • [42] A microcomputed tomography evaluation of the shaping ability of three thermally-treated nickel-titanium rotary file systems in curved canals
    Huang, Zhuwei
    Quan, Jingjing
    Liu, Jia
    Zhang, Wen
    Zhang, Xiaolei
    Hu, Xiaoli
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (01) : 325 - 334
  • [43] Shaping ability of NiTi reciprocating file systems R-motion and waveOne gold in mesial canals of mandibular molars; micro CT study
    Alsulaiman, Mona
    Alsofi, Loai
    Alhabib, Mey A.
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [44] Microcomputed Assessment of Transportation, Centering Ratio, Canal Area, and Volume Increase after Single-file Rotary and Reciprocating Glide Path Instrumentation in Curved Root Canals: A Laboratory Study
    Aydin, Zeliha Ugur
    Keskin, Neslihan Busra
    Ozyurek, Taha
    Geneci, Ferhat
    Ocak, Mert
    Celik, Hakan Hamdi
    JOURNAL OF ENDODONTICS, 2019, 45 (06) : 791 - 796
  • [45] Evaluation of Microbial Reduction in Root Canals Instrumented with Reciprocating and Rotary Systems
    De Oliveiraruna Paloma, Bruna
    Aguari, Carlos Meneze
    Camara, Andrea Cruz
    De Albuquerque, Miracy Muniz
    Correia, Ana Cristina Regis De Barros
    Soares, Monica Felts De La Roca
    ACTA STOMATOLOGICA CROATICA, 2015, 49 (04) : 294 - 303
  • [46] Comparative Evaluation of Root Canal Transportation by Three NiTi Single-File Systems in Curved Canals: A Cone Beam Computed Tomography Study
    Saberi, Eshaghali
    Farhad-Mollashahi, Narges
    Bijari, Shima
    Daryaeian, Mohammad
    INTERNATIONAL JOURNAL OF DENTISTRY, 2018, 2018
  • [47] Shaping ability of rotatory or reciprocating instruments in curved canals: a micro-computed tomographic study
    Jardine, Alexander Pompermayer
    da Rosa, Ricardo Abreu
    Santini, Manuela Favarin
    Zaccara, Ivana Maria
    Reis So, Marcus Vinicius
    Poli Kopper, Patricia Maria
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [48] The incidence of dentinal cracks during root canal preparations with reciprocating single-file and rotary-file systems: A meta-analysis
    Wei, Xi
    Hu, Bo
    Peng, Haiyang
    Tang, Ming
    Song, Jinlin
    DENTAL MATERIALS JOURNAL, 2017, 36 (03) : 243 - 252
  • [49] Micro-Computed Tomography (Micro-CT) Evaluation of Effects of Different Rotary Glide Path Techniques on Canal Transportation and Centering in Curved Root Canals
    Cesaitiene, Gabriele
    Venskutonis, Tadas
    Maciulskiene, Vita
    Cicenas, Vaidotas
    Samaitis, Vykintas
    Jasiuniene, Elena
    MEDICAL SCIENCE MONITOR, 2019, 25 : 6351 - 6358
  • [50] Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals
    Arvaneh, Shakiba
    Schwesig, Rene
    Haghighat, Shahpar
    Gernhardt, Christian Ralf
    MEDICINA-LITHUANIA, 2025, 61 (03):