DIAGNOSTIC CAPACITY OF POCKET-SIZED ULTRASOUND DEVICES AT POINT OF CARE BY A NON-RADIOLOGIST RESIDENT IN PATIENTS WITH SUSPECTED ABDOMINAL PATHOLOGY

被引:4
|
作者
Lopez Zuniga, Miguel Angel [1 ]
Vallejo Palomino, Tomas [2 ]
Martin Toro, Miriam Auxiliadora [3 ]
Castillo Fernandez, Alba Maria [1 ]
Gerez Neira, Desiree [1 ]
Vilchez Parras, Ascension Maria [1 ]
Villa Garcia, Maria Isabel [1 ]
Martinez Colmenero, Justo [1 ]
Padilla Moreno, Francisco [1 ]
Campos Calero, Alvaro [1 ]
Torres Macho, Juan [4 ]
机构
[1] Jaen Hosp Complex, Internal Med, Ave Ejercito Espanol 10, Jaen 23007, Spain
[2] Jaen Hosp Complex, Dept Radiol, Jaen, Spain
[3] Jaen Hosp Complex, Dept Cardiol, Jaen, Spain
[4] Hosp Univ Infanta Leonor, Dept Internal Med, Madrid, Spain
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2020年 / 46卷 / 02期
关键词
Point-of-care ultrasound; Abdominal ultrasound; Point of care; Pocket-sized device; Bedside; PHYSICAL-EXAMINATION; ULTRASONOGRAPHY; ACCURACY; ECHOCARDIOGRAPHY; FEASIBILITY;
D O I
10.1016/j.ultrasmedbio.2019.10.019
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Studies have reported the usefulness and tolerability in practice of abdominal ultrasound performed by non-radiologists in various clinical situations. This prospective observational single-center study included 184 patients hospitalized in an internal medicine department who underwent conventional abdominal ultrasound. A medical resident with basic training performed point-of-care clinical ultrasound using a pocket-sized device. The concordance obtained between the researcher and the radiologist was good (k >0.6) for the gallbladder, splenomegaly, longitudinal diameter of the kidney, presence of renal cysts and hydronephrosis. The specificity was >90% for all parameters assessed except normal renal size. A negative predictive value >90% was obtained for all variables studied except the presence of hepatic space-occupying lesions and gallbladder pathology, the negative predictive values for which were >80%. A positive predictive value >80% was obtained for all of these variables, except the presence of adenopathies, hepatomegaly, space-occupying lesions, echogenicity and/or enlargement of the biliary tract, left renal atrophy and right renal masses. We conclude there was a high concordance between a conventional abdominal study and that performed with a pocket-sized ultrasound device after a brief learning curve. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 30 条
  • [1] Pocket-sized point-of-care cardiac ultrasound devices Role in the emergency department
    Colclough, A.
    Nihoyannopoulos, P.
    HERZ, 2017, 42 (03) : 255 - 261
  • [2] Feasibility and Diagnostic Accuracy of Point-of-Care Abdominal Sonography by Pocket-Sized Imaging Devices, Performed by Medical Residents
    Kjesbu, Ingunn E.
    Laursen, Christian B.
    Graven, Torbjorn
    Holden, Hans Martin
    Romo, Bjornar
    Andersen, Garrett Newton
    Mjolstad, Ole Christian
    Lassen, Annmarie
    Dalen, Havard
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (06) : 1195 - 1202
  • [3] Economic Benefit of Using a Pocket-Sized Ultrasound Device for the Initial Diagnostic Test in Symptomatic Patients with Suspected Gallstone Disease
    DSouza, Anna
    Patel, Pankaj
    Shah, Manan
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 : S389 - S389
  • [4] Orthopaedic Residents' Interpretation of Point-of-Care Assessment of Distal Radial Fractures with Use of Pocket-Sized Ultrasound Devices
    Lau, Brian C.
    Motamedi, Daria
    Lee, Nicolas
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (09):
  • [5] Can Diaphragm Dysfunction Be Reliably Evaluated with Pocket-Sized Ultrasound Devices in Intensive Care Unit?
    Gursel, Gul
    Inci, Kamil
    Alasgarova, Zenfira
    CRITICAL CARE RESEARCH AND PRACTICE, 2018, 2018
  • [6] Reproducibility and diagnostic accuracy of pocket-sized ultrasound devices in ruling out compensated cirrhosis of mixed etiology
    Costantino, Andrea
    Piagnani, Alessandra
    Nandi, Nicoletta
    Sciola, Valentina
    Maggioni, Marco
    Donato, Francesca
    Vecchi, Maurizio
    Lampertico, Pietro
    Casazza, Giovanni
    Fraquelli, Mirella
    EUROPEAN RADIOLOGY, 2022, 32 (07) : 4609 - 4615
  • [7] Equipping non-radiologist with basic point of care ultrasound skills- it can save lives!
    YK Liew
    Critical Ultrasound Journal, 7 (Suppl 1)
  • [8] Reproducibility and diagnostic accuracy of pocket-sized ultrasound devices in ruling out compensated cirrhosis of mixed etiology
    Andrea Costantino
    Alessandra Piagnani
    Nicoletta Nandi
    Valentina Sciola
    Marco Maggioni
    Francesca Donato
    Maurizio Vecchi
    Pietro Lampertico
    Giovanni Casazza
    Mirella Fraquelli
    European Radiology, 2022, 32 : 4609 - 4615
  • [9] Diagnostic accuracy of non-radiologist performed ultrasound for abdominal aortic aneurysm: systematic review and meta-analysis
    Concannon, E.
    McHugh, S.
    Healy, D. A.
    Kavanagh, E.
    Burke, P.
    Moloney, M. Clarke
    Walsh, S. R.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2014, 68 (09) : 1122 - 1129
  • [10] Diagnostic accuracy and feasibility of bedside pocket-sized ultrasound examination in patients admitted to an internal medicine department
    Andersen, G. N.
    Haugen, B. O.
    Graven, T.
    Mjoelstad, O. C.
    Dalen, H.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183 : 699 - 699