Breakdown of Carr-Purcell Meiboom-Gill spin echoes in inhomogeneous fields

被引:9
|
作者
Jarenwattananon, Nanette N. [1 ]
Bouchard, Louis-S. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Chem & Biochem, 607 Charles E Young Dr East, Los Angeles, CA 90095 USA
来源
JOURNAL OF CHEMICAL PHYSICS | 2018年 / 149卷 / 08期
基金
美国国家科学基金会;
关键词
NUCLEAR MAGNETIZATION; RESTRICTED GEOMETRY; DIFFUSION; GRADIENT; RELAXATION; DECAY; NMR;
D O I
10.1063/1.5043495
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The Carr-Purcell Meiboom-Gill (CPMG) experiment has been used for decades to measure nuclear-spin transverse (T-2) relaxation times. In the presence of magnetic field inhomogeneities, the limit of short interpulse spacings yields the intrinsic T-2 time. Here, we show that the signal decay in such experiments exhibits fundamentally different behaviors between liquids and gases. In gases, the CPMG unexpectedly fails to eliminate the inhomogeneous broadening due to the non-Fickian nature of the motional averaging. Published by AIP Publishing.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Suppressing phase decoherence of a single atom qubit with Carr-Purcell-Meiboom-Gill sequence
    Yu, Shi
    Xu, Peng
    He, Xiaodong
    Liu, Min
    Wang, Jin
    Zhan, Mingsheng
    OPTICS EXPRESS, 2013, 21 (26): : 32130 - 32140
  • [22] Comparison of electron spin relaxation times measured by Carr-Purcell-Meiboom-Gill and two-pulse spin-echo sequences
    Harbridge, JR
    Eaton, SS
    Eaton, GR
    JOURNAL OF MAGNETIC RESONANCE, 2003, 164 (01) : 44 - 53
  • [23] MODULATION OF CARR-PURCELL SPIN-ECHO TRAINS IN HOMONUCLEAR AALPHABXX SYSTEMS
    ALLERHAND, A
    JOURNAL OF CHEMICAL PHYSICS, 1969, 50 (12): : 5429 - +
  • [24] Trading sensitivity for information: Carr-Purcell-Meiboom-Gill acquisition in solid-state NMR
    Dey, Krishna K.
    Ash, Jason T.
    Trease, Nicole M.
    Grandinetti, Philip J.
    JOURNAL OF CHEMICAL PHYSICS, 2010, 133 (05):
  • [25] A MODIFIED SIGNAL INTENSITY EQUATION OF CARR-PURCELL-MEIBOOM-GILL PULSE SEQUENCE FOR MR IMAGING
    YAMADA, S
    MATSUZAWA, T
    YAMADA, K
    YOSHIOKA, S
    ONO, S
    HISHINUMA, T
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1989, 158 (03): : 203 - 209
  • [26] Increased 29Si NMR sensitivity in glasses with a Carr-Purcell-Meiboom-Gill echotrain
    Malfait, W. J.
    Halter, W. E.
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2008, 354 (34) : 4107 - 4114
  • [27] A NOTE ON THE SIGNAL INTENSITY OF THE 2ND SPIN-ECHO IN CARR-PURCELL-MEIBOOM-GILL SEQUENCE OF TURBULENT FLOWS
    KAWABE, Y
    FUKUDA, K
    HIRAI, A
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1983, 52 (07) : 2308 - 2311
  • [28] A joint linear reconstruction for multishot diffusion weighted non-Carr-Purcell-Meiboom-Gill fast spin echo with full signal
    Lee, Philip K.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (05) : 2139 - 2156
  • [29] EXPRESSION FORMS AND CHARACTERISTICS OF CARR-PURCELL-MEIBOOM-GILL SEQUENCE MAGNETIC-RESONANCE IMAGES
    YAMADA, S
    MATSUZAWA, T
    YAMADA, K
    ONO, S
    HISHINUMA, T
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1989, 157 (03): : 185 - 192
  • [30] J-COUPLING MEASUREMENTS USING CARR-PURCELL SPIN-ECHO TECHNIQUES
    KOKSAL, F
    CHEMICAL PHYSICS LETTERS, 1976, 44 (01) : 187 - 189