共 50 条
Value of Retrospective Fusion of PET and MR Images in Detection of Hepatic Metastases: Comparison with 18F-FDG PET/CT and Gd-EOB-DTPA-Enhanced MRI
被引:117
|作者:
Donati, Olivio F.
[1
]
Hany, Thomas F.
[2
]
Reiner, Caecilia S.
[1
]
von Schulthess, Gustav K.
[2
]
Marincek, Borut
[1
]
Seifert, Burkhardt
[3
]
Weishaupt, Dominik
[1
]
机构:
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Div Nucl Med, CH-8091 Zurich, Switzerland
[3] Univ Zurich, Inst Social & Prevent Med, Biostat Unit, CH-8006 Zurich, Switzerland
关键词:
hepatology;
MRI;
oncology;
PET/MRI;
PET/CT;
liver metastases;
multimodality imaging;
positron emission tomography;
POSITRON-EMISSION-TOMOGRAPHY;
COLORECTAL LIVER METASTASES;
FDG-PET/CT;
COMPUTED-TOMOGRAPHY;
SPIRAL CT;
RESECTION;
IMPACT;
CANCER;
LESIONS;
DIAGNOSIS;
D O I:
10.2967/jnumed.109.068510
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
The purpose of this study was to compare the accuracy of lesion detection and diagnostic confidence between F-18-FDG PET/CT, gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI, and retrospectively fused PET and MRI (PET/MRI). Methods: Thirty-seven patients (mean age +/- SD, 60.2 +/- 12 y) with suspected liver metastases underwent PET/CT and Gd-EOB-DTPA-enhanced MRI within 0-30 d (mean, 11.9 +/- 9 d). PET and Gd-EOB-DTPA-enhanced MR image data were retrospectively fused. Images were reviewed independently by 2 readers who identified and characterized liver lesions using PET/CT, Gd-EOB-DTPA-enhanced MRI, and PET/MRI. Each liver lesion was graded on a 5-point confidence scale ranging from definitely benign (grade of 1) to definitely malignant (grade of 5). The accuracy of each technique was determined by receiver-operating-characteristic analysis. Histopathology served as the standard of reference for all patients with malignant lesions. Results: A total of 85 liver lesions (55 liver metastases [65%] and 30 benign lesions [35%]) were present in 29 (78%) of the 37 patients. Twenty-four (65%) of the 37 patients had liver metastases. The detection rate of liver lesions was significantly lower for PET/CT than for Gd-EOB-DTPA-enhanced MRI (64% and 85%; P = 0.002). Sensitivity in the detection and characterization of liver metastases for PET/CT, Gd-EOB-DTPA-enhanced MRI, PET/MRI in reader 1, and PET/MRI in reader 2 was 76%, 91%, 93%, and 93%, respectively; the respective specificity values were 90%, 100%, 87%, and 97%. The difference in sensitivity between PET/CT and PET/MRI was significant (P = 0.023). The level of confidence regarding liver lesions larger than 1 cm in diameter was significantly higher in PET/MRI than in PET/CT (P = 0.046). Accuracy values (area under the receiver-operating-characteristic curve) for PET/CT, Gd-EOB-DTPA-enhanced MRI, PET/MRI in reader 1, and PET/MRI in reader 2 were 0.85, 0.94, 0.92, and 0.96, respectively. Conclusion: The sensitivity of Gd-EOB-DTPA-enhanced MRI and PET/MRI in the detection of liver metastases is higher than that of PET/CT. Diagnostic confidence was significantly better with PET/MRI than with PET/CT regarding lesions larger than 1 cm in diameter. Compared with Gd-EOB-DTPA-enhanced MRI, PET/MRI resulted in a nonsignificant increase in sensitivity and diagnostic confidence.
引用
收藏
页码:692 / 699
页数:8
相关论文