A Flexible Dual-Analyte Electrochemical Biosensor for Salivary Glucose and Lactate Detection

被引:21
|
作者
Liu, Mingyang [1 ]
Yang, Muqun [1 ]
Wang, Muxue [2 ]
Wang, Han [2 ]
Cheng, Jing [2 ]
机构
[1] Tsinghua Univ, Tsinghua Berkeley Shenzhen Inst TBSI, Precis Med & Healthcare Res Ctr, Shenzhen 518055, Peoples R China
[2] Tsinghua Univ, Sch Med, Dept Biomed Engn, Beijing 100084, Peoples R China
来源
BIOSENSORS-BASEL | 2022年 / 12卷 / 04期
基金
国家重点研发计划;
关键词
electrochemical biosensing; salivary metabolites; dual-analyte biosensor; MOUTHGUARD BIOSENSOR; URIC-ACID; METERS;
D O I
10.3390/bios12040210
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical biosensors have been widely applied in the development of metabolite detection systems for disease management. However, conventional intravenous and fingertip blood tests are invasive and cannot track dynamic trends of multiple metabolites. Among various body fluids, saliva can be easily accessed and is regarded as a promising candidate for non-invasive metabolite detection. Recent works on the development of electrochemical biosensors for monitoring salivary metabolites have demonstrated high sensitivity and wide linear range. However, most of this research has been focused on salivary detection of a single metabolite. Here, we present a dual-channel electrochemical biosensor for simultaneous detection of lactate and glucose in saliva based on a flexible screen-printed electrode with two working electrodes. The sensitivities of glucose and lactate channels were 18.7 mu A/(mM.cm(2)) and 21.8 mu A/(mM.cm(2)), respectively. The dual-channel biosensor exhibited wide linear ranges of 0-1500 mu M for the glucose channel and 0-2000 mu M for the lactate channel and the cross-talk between the two detection channels was negligible, which made it adequately suitable for sensing low-level salivary metabolites. Such attractive characteristics demonstrate the potential of this dual-analyte biosensor in the development of wearable devices for monitoring disease progression and fitness.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Immobilization of Lactate as an Electroactive Indicator on Pencil Graphite Electrode for the Development of a New Electrochemical Biosensor for the Detection of Lactate Dehydrogenase
    Majidi, M. R.
    Gholizadeh, S.
    Hejazi, M. S.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2011, 8 (01) : 59 - 67
  • [32] Fabrication of a Flexible Biosensor Based on an Organic Field-effect Transistor for Lactate Detection
    Minamiki, Tsukuru
    Tokito, Shizuo
    Minami, Tsuyoshi
    ANALYTICAL SCIENCES, 2019, 35 (01) : 103 - 106
  • [33] Immobilization of lactate as an electroactive indicator on pencil graphite electrode for the development of a new electrochemical biosensor for the detection of lactate dehydrogenase
    M. R. Majidi
    S. Gholizadeh
    M. S. Hejazi
    Journal of the Iranian Chemical Society, 2011, 8 : 59 - 67
  • [34] Towards a dual in-line electrochemical biosensor for the determination of glucose and hydrogen peroxide
    Narayanan, Jeyaraman Shankara
    Slaughter, Gymama
    BIOELECTROCHEMISTRY, 2019, 128 : 56 - 65
  • [35] Polyaniline/Graphene-Based Electrochemical Biosensor for Sensitive Detection of Glucose
    Ge, Yuqing
    Chen, Zhihua
    Jin, Qinghui
    Mao, Hongju
    Liu, Jianshe
    Zhao, Jianlong
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (09) : 5036 - 5038
  • [36] Facile Fabrication of a Graphene-based Electrochemical Biosensor for Glucose Detection
    Zhang Yanqin
    Fan Youjun
    Wang Shanshan
    Tan Yiliang
    Shen Xingcan
    Shi Zujin
    CHINESE JOURNAL OF CHEMISTRY, 2012, 30 (05) : 1163 - 1167
  • [37] A Copper-Based Biosensor for Dual-Mode Glucose Detection
    Li, Kai
    Xu, Xiaoyu
    Liu, Wanshan
    Yang, Shouzhi
    Huang, Lin
    Tang, Shuai
    Zhang, Ziyue
    Wang, Yuning
    Chen, Fangmin
    Qian, Kun
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [38] Flexible Electrochemical Sensing Label for the Detection of Glucose Adulteration in Honey
    Chugh, Vibhas
    Bhattacharjya, Tathagata
    Das, Chirantan
    Tripathy, Kamalesh
    Bhattacharjee, Mitradip
    IEEE SENSORS JOURNAL, 2024, 24 (09) : 13823 - 13830
  • [39] Flexible enzymatic biosensor based on graphene sponge for glucose detection in human sweat
    Li, Bin
    Wu, Xingmin
    Shi, Chaosheng
    Dai, Yongqiang
    Zhang, Jingfei
    Liu, Wanyu
    Wu, Chen
    Zhang, Yangfan
    Huang, Xue
    Zeng, Wei
    SURFACES AND INTERFACES, 2023, 36
  • [40] A dual-functional polyaniline film-based flexible electrochemical sensor for the detection of pH and lactate in sweat of the human body
    Zhu, Chonghui
    Xue, Hua
    Zhao, Hongran
    Fei, Teng
    Liu, Sen
    Chen, Qidai
    Gao, Bingrong
    Zhang, Tong
    TALANTA, 2022, 242