Standardisation and precise determination of the half-life of 44Sc

被引:22
|
作者
Garcia-Torano, E. [1 ]
Peyres, V. [1 ]
Roteta, M. [1 ]
Sanchez-Cabezudo, A. I. [1 ]
Romero, E. [2 ]
Martinez Ortega, A. [2 ]
机构
[1] CIEMAT, Lab Metrol Radiac Ionizantes, Avda Complutense 40, E-28040 Madrid, Spain
[2] CIEMAT, Unidad Aplicac Biomed & Farmacocinet, Avda Complutense 40, E-28040 Madrid, Spain
关键词
Sc-44; Half-life; Standardisation; Positron emitters; RADIONUCLIDE; SCANDIUM;
D O I
10.1016/j.apradiso.2015.12.007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The half-life of the positron-emitter Sc-44 has been determined by following the decay rate with two measurement systems; an Ionisation Chamber and a HPGe detector. The combination of seven results gives a value of T-1/2=4.042 (25) h, about 2% higher than the recommended value of T-1/2=3.97 (4) h (Browne, 2011) and with a lower uncertainty. This radionuclide has also been standardised by coincidence counting, and liquid scintillation counting techniques. A Ti-44/Sc-44 generator developed at CIEMAT was used to obtain the Sc-44 solutions used in all measurements. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:314 / 318
页数:5
相关论文
共 50 条
  • [31] CARRIER-FREE SEPARATION OF TITANIUM AND HALF-LIFE DETERMINATION OF 44TI
    WING, J
    WAHLGREN, MA
    STEVENS, CM
    ORLANDIN.KA
    JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1965, 27 (03): : 487 - &
  • [32] Half-life ... What half-life?
    Lewis, BJ
    JOURNAL OF MANAGEMENT IN ENGINEERING, 1998, 14 (01) : 4 - 4
  • [33] PRECISE MEASUREMENT OF HALF-LIFE OF CA-49
    HANSEN, JW
    PRUSSIN, SG
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1970, 21 (06): : 335 - &
  • [34] Precise measurement of the 19Ne half-life
    Triambak, S.
    4TH INTERNATIONAL CONFERENCE ON PROTON EMITTING NUCLEI AND RELATED TOPICS, 2011, 1409
  • [35] A precise measurement of the 117mSn half-life
    Domingo, T.
    Starosta, K.
    Chester, A.
    Williams, J.
    APPLIED RADIATION AND ISOTOPES, 2017, 119 : 101 - 104
  • [36] POSTOPERATIVE DETERMINATION OF PARATHYRIN HALF-LIFE
    RADJAIPOUR, M
    MAIER, G
    SEIF, EJ
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1988, 26 (11): : 764 - 764
  • [37] Precise measurement of the half-life of 61Cu
    Cvetinovic, Aleksandra
    Likar, Andrej
    Lipoglavsek, Matej
    Mihelic, Andrej
    Petrovic, Toni
    Vesic, Jelena
    Vodenik, Branko
    APPLIED RADIATION AND ISOTOPES, 2015, 104 : 160 - 166
  • [38] The half-life of titanium 44 and SN 1987A
    Mochizuki, YS
    Kumagai, S
    HOT UNIVERSE, 1998, (188): : 241 - 242
  • [39] On the half-life of 44Ti by results in meteorites
    Bonino, G
    Castagnoli, GC
    Taricco, C
    Bhandari, N
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-GEOPHYSICS AND SPACE PHYSICS, 1997, 20 (06): : 955 - 959
  • [40] Half-life determination of La decay
    CTBT Beijing National Data Centre, Beijing 100085, China
    不详
    不详
    He Jishu, 2008, 2 (115-118):