Objective analysis of tomographic ventilation-perfusion scintigraphy in pulmonary embolism

被引:34
|
作者
Harris, Benjamin
Bailey, Dale
Miles, Susan
Bailey, Elizabeth
Rogers, Kerry
Roach, Paul
Thomas, Paul
Hensley, Michael
King, Gregory G.
机构
[1] Univ Sydney, Fac Med, No Clin Sch, Sydney, NSW 2006, Australia
[2] Woolcock Inst Med Res, Sydney, NSW, Australia
[3] Royal N Shore Hosp, Dept Med Res, Sydney, NSW, Australia
[4] Royal N Shore Hosp, Dept Nucl Med, Sydney, NSW, Australia
[5] Univ Sydney, Sch Med Radiat Sci, Sydney, NSW 2006, Australia
[6] Univ Newcastle, Sch Med & Publ Hlth, Newcastle, NSW 2308, Australia
[7] John Hunter Hosp, Dept Resp & Sleep Med, Newcastle, NSW, Australia
[8] John Hunter Hosp, Dept Nucl Med, Newcastle, NSW, Australia
关键词
tomography; emission-computed; single-photon; radionuclide imaging; ventilation-perfusion ratio; pulmonary embolism; image processing; computer-assisted;
D O I
10.1164/rccm.200608-1110OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Ventilation-perfusion scintigraphy is highly sensitive for pulmonary embolism (PE), but its clinical usefulness is limited by its nondiagnostic rate. Objective analysis of single photon emission computed tomography (SPECT) three-dimensional scintigraphy may improve its diagnostic performance compared with subjective interpretation. Objectives: To determine the diagnostic accuracy of objective SPECT analysis in PE. Methods: We determined the ventilation/perfusion (V/Q) relationship using SPECT scintigraphy in a retrospective cohort of 73 patients. Measures of V/Q heterogeneity (logSD(Q), logSD(V), logSD(VQR)), including a novel parameter, the weighted median V/Q value, were calculated. Using receiver operating characteristic (ROC) analysis, each parameter's diagnostic accuracy was determined. The weighted median V/Q value was then assessed prospectively in a second cohort of 50 patients. Measurements and Main Results: In cohort 1, all parameters of V/Q heterogeneity were higher in patients with PE (p < 0.002). The weighted median V/Q had the highest area under the ROC curve (0.93; 95% confidence interval, 0.87-0.98). When applied to the prospective cohort, the area under the ROC curve was 0.87 (95% confidence interval, 0.75-0.99), with diagnostic cutoff values having negative and positive predictive values of 96 and 83%, respectively. In the retrospective and prospective cohorts, 82 and 73% of initially reported intermediate or low probability scans had diagnostic weighted median V/Q values, with 90 and 100% accuracy, respectively. Conclusions: Objective analysis of SPECT scintigraphy has a high diagnostic accuracy in patients with suspected PE. Objective analysis has the potential to reduce the number of nondiagnostic scan results, and may be useful for quantifying V/Q mismatch in other pulmonary disorders.
引用
收藏
页码:1173 / 1180
页数:8
相关论文
共 50 条
  • [41] Cost Analysis Comparing Computed Tomographic Pulmonary Angiography (CTPA) and Ventilation-Perfusion (V/Q) Scanning for the Diagnosis of Pulmonary Embolism
    Dorreen, Alastair
    Skedgel, Chris
    Rodger, Marc A.
    Kahn, Susan R.
    Kovacs, Michael J.
    Philip, Wells
    Anderson, David
    BLOOD, 2010, 116 (21) : 251 - 251
  • [42] CLINICAL VENTILATION-PERFUSION SCINTIGRAPHY
    FAZIO, F
    WOLLMER, P
    CLINICAL PHYSIOLOGY, 1981, 1 (04): : 323 - 337
  • [43] VENTILATION-PERFUSION SCINTIGRAPHY IN PNEUMOLOGY
    HUTTEMANN, U
    NUCLEAR MEDICINE-NUKLEARMEDIZIN, 1987, 26 (03): : 108 - 110
  • [44] Pulmonary Embolism Diagnosis and Mortality With Pulmonary CT Angiography Versus Ventilation-Perfusion Scintigraphy: Evidence of Overdiagnosis With CT?
    Sheh, Steven H.
    Bellin, Eran
    Freeman, Katherine D.
    Haramati, Linda B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (06) : 1340 - 1345
  • [45] HEMODYNAMIC AND ANGIOGRAPHIC CORRELATIONS TO ESTABLISH SPECIFICITY OF ABNORMAL LUNG VENTILATION-PERFUSION SCINTIGRAPHY IN PULMONARY-EMBOLISM
    MORRISON, S
    VISMARA, LA
    BERMAN, DS
    PRICE, JE
    DENARDO, GL
    MILLER, RR
    BAILEY, GJ
    MASON, DT
    BOGREN, H
    CLINICAL RESEARCH, 1976, 24 (02): : A87 - A87
  • [46] MR angiography with sensitivity encoding (SENSE) for suspected pulmonary embolism: Comparison with MDCT and ventilation-perfusion scintigraphy
    Ohno, Y
    Higashino, T
    Takenaka, D
    Sugimoto, K
    Yoshikawa, T
    Kawai, H
    Fujii, M
    Hatabu, H
    Sugimura, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (01) : 91 - 98
  • [47] HEMODYNAMIC AND ANGIOGRAPHIC CORRELATIONS TO ESTABLISH SPECIFICITY OF ABNORMAL LUNG VENTILATION-PERFUSION SCINTIGRAPHY IN PULMONARY-EMBOLISM
    VISMARA, LA
    MORRISON, S
    BERMAN, DS
    PRICE, JE
    DENARDO, GL
    MILLER, RR
    BAILEY, GJ
    MASON, DT
    BOGREN, H
    CLINICAL RESEARCH, 1976, 24 (03): : A244 - A244
  • [48] SENSITIVITY AND SPECIFICITY OF VENTILATION-PERFUSION SCANNING FOR PULMONARY-EMBOLISM
    HULL, RD
    RASKOB, GE
    ARTERIOSCLEROSIS, 1990, 10 (05): : A912 - A912
  • [49] SENSITIVITY AND SPECIFICITY OF VENTILATION-PERFUSION SCANNING FOR PULMONARY-EMBOLISM
    HULL, RD
    RASKOB, GE
    CIRCULATION, 1990, 82 (04) : 604 - 604
  • [50] VALUE OF THE STUDY OF VENTILATION-PERFUSION RATIO IN PULMONARY-EMBOLISM
    CASTEJON, I
    CHAMORRO, JL
    RAMOS, J
    MONCALEANO, G
    MARANA, G
    BERROCAL, JO
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1980, 5 (03): : A10 - A10