The efficiency of the electrocoagulation process in reducing fluoride: application of inductive alternating current and polarity inverter

被引:25
|
作者
Alimohammadi, M. [1 ,2 ,3 ]
Mesdaghinia, A. [1 ,2 ]
Shayesteh, M. H. [4 ]
Mansoorian, H. J. [1 ]
Khanjani, N. [5 ]
机构
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[2] Univ Tehran Med Sci, IER, CWQR, Tehran, Iran
[3] Univ Tehran Med Sci, HERC, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Toxicol & Pharmacol, Fac Pharm, Tehran, Iran
[5] Kerman Univ Med Sci, Environm Hlth Engn Res Ctr, Kerman, Iran
关键词
Electrochemical treatment; Hybrid plate electrodes; Electrode connection model; Alternating current; Polarity inverter; Fluoride removal; SEMICONDUCTOR WASTE-WATER; AQUEOUS-SOLUTION; OPERATING PARAMETERS; SIMULTANEOUS REMOVAL; ALUMINUM ELECTRODES; ADSORPTIVE REMOVAL; DRINKING-WATER; IRON; ADSORBENT; METAL;
D O I
10.1007/s13762-019-02297-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, using hybrid Al and Fe plate electrodes in an electrochemical cell by using inductive alternating current and polarity inverter as an alternative method for decreasing fluoride in drinking water sequentially, by the electrocoagulation process has been evaluated. The effect of operational parameters such as the type of current, paired hybrid electrodes and polarity inverter, pH, current density, electrolysis time, charge loading and flow rate on the percent of fluoride removal along with the amount of energy and electrode consumed and amount of sludge produced was evaluated. In the following optimum operation conditions: paired hybrid Al-Fe electrodes with polarity inverter, pH=6, current density=12 mA/cm(2), electrolysis time=40 min, charge loading 0.609 Faradays/m(3) and flow rate 75 ml/min, the efficiency of fluoride removal, energy and electrode consumption, flow efficiency, amount of sludge produced and sedimentation capacity were, respectively, 95% (from initial 4.93 to 0.24 mg/l), 0.9 kWh/m(3), 1.42 kg/m(3), 110%, 0.108 kg/m(3) and 0.073 l/g. The results showed that the electrocoagulation process by using alternating current and polarity inverter is a very efficient method for removing fluoride from drinking water.
引用
收藏
页码:8239 / 8254
页数:16
相关论文
共 33 条
  • [31] A novel ANN approach for modeling of alternating pulse current electrocoagulation-flotation (APC-ECF) process: Humic acid removal from aqueous media
    Hasani, Gona
    Daraei, Hiva
    Shahrnoradi, Behzad
    Gharibi, Fardin
    Maleki, Afshin
    Yetilmezsoy, Kaan
    McKay, Gordon
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2018, 117 : 111 - 124
  • [32] Optimization of operational parameters using central composite design in the peroxi-alternating current-electrocoagulation process for the pollutant removal with determination of power consumption from industrial wastewater
    Asaithambi, Perumal
    Desta, Wendesen Mekonin
    Hussen, Mohammed
    Yesuf, Mamuye Busier
    Beyene, Dejene
    ELECTROCHEMICAL SCIENCE ADVANCES, 2024, 4 (06):
  • [33] Novel SVPWM Switching Pattern for High Efficiency 15KW Current-fed Quasi-Z-Source Inverter in HEV Motor Drive Application
    Lei, Qin
    Cao, Dong
    Peng, Fang. Z.
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 2407 - 2420