The efficiency of the electrocoagulation process in reducing fluoride: application of inductive alternating current and polarity inverter

被引:25
|
作者
Alimohammadi, M. [1 ,2 ,3 ]
Mesdaghinia, A. [1 ,2 ]
Shayesteh, M. H. [4 ]
Mansoorian, H. J. [1 ]
Khanjani, N. [5 ]
机构
[1] Univ Tehran Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[2] Univ Tehran Med Sci, IER, CWQR, Tehran, Iran
[3] Univ Tehran Med Sci, HERC, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Toxicol & Pharmacol, Fac Pharm, Tehran, Iran
[5] Kerman Univ Med Sci, Environm Hlth Engn Res Ctr, Kerman, Iran
关键词
Electrochemical treatment; Hybrid plate electrodes; Electrode connection model; Alternating current; Polarity inverter; Fluoride removal; SEMICONDUCTOR WASTE-WATER; AQUEOUS-SOLUTION; OPERATING PARAMETERS; SIMULTANEOUS REMOVAL; ALUMINUM ELECTRODES; ADSORPTIVE REMOVAL; DRINKING-WATER; IRON; ADSORBENT; METAL;
D O I
10.1007/s13762-019-02297-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, using hybrid Al and Fe plate electrodes in an electrochemical cell by using inductive alternating current and polarity inverter as an alternative method for decreasing fluoride in drinking water sequentially, by the electrocoagulation process has been evaluated. The effect of operational parameters such as the type of current, paired hybrid electrodes and polarity inverter, pH, current density, electrolysis time, charge loading and flow rate on the percent of fluoride removal along with the amount of energy and electrode consumed and amount of sludge produced was evaluated. In the following optimum operation conditions: paired hybrid Al-Fe electrodes with polarity inverter, pH=6, current density=12 mA/cm(2), electrolysis time=40 min, charge loading 0.609 Faradays/m(3) and flow rate 75 ml/min, the efficiency of fluoride removal, energy and electrode consumption, flow efficiency, amount of sludge produced and sedimentation capacity were, respectively, 95% (from initial 4.93 to 0.24 mg/l), 0.9 kWh/m(3), 1.42 kg/m(3), 110%, 0.108 kg/m(3) and 0.073 l/g. The results showed that the electrocoagulation process by using alternating current and polarity inverter is a very efficient method for removing fluoride from drinking water.
引用
收藏
页码:8239 / 8254
页数:16
相关论文
共 33 条
  • [1] The efficiency of the electrocoagulation process in reducing fluoride: application of inductive alternating current and polarity inverter
    M. Alimohammadi
    A. Mesdaghinia
    M. H. Shayesteh
    H. J. Mansoorian
    N. Khanjani
    International Journal of Environmental Science and Technology, 2019, 16 : 8239 - 8254
  • [2] Drinking water softening with electrocoagulation process: Influence of direct and alternating currents as inductive with different arrangement rod electrodes and polarity inverter
    Yaghmaeian, K.
    Mahvi, A. H.
    Nasseri, S.
    Shayesteh, M. Hooshangi
    Mansoorian, H. Jafari
    Khanjani, N.
    SCIENTIA IRANICA, 2020, 27 (03) : 1275 - 1292
  • [3] Drinking water softening with electrocoagulation process: Influence of direct and alternating currents as inductive with different arrangement rod electrodes and polarity inverter
    Yaghmaeian K.
    Mahvi A.H.
    Nasseri S.
    Shayesteh M.H.
    Mansoorian H.J.
    Khanjani N.
    Mansoorian, H. Jafari (h.mansoorian@yahoo.com), 1600, Sharif University of Technology (27): : 1275 - 1292
  • [4] Effects of alternating and direct current in electrocoagulation process on the removal of fluoride from water
    Vasudevan, Subramanyan
    Balasingam, Suresh Kannan
    Lakshmi, Jothinathan
    Mohanraj, Subramanian
    Sozhan, Ganapathy
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2011, 86 (03) : 428 - 436
  • [5] Taguchi experimental design for electrocoagulation process using alternating and direct current on fluoride removal from water
    Ghanizadeh, Ghader
    Neghab, Gholamreza Shariati
    Salem, Mohammad
    Khalagi, Kazem
    DESALINATION AND WATER TREATMENT, 2016, 57 (27) : 12675 - 12683
  • [6] Effect of alternating and direct current in an electrocoagulation process on the removal of cadmium from water
    Vasudevan, S.
    Lakshmi, J.
    WATER SCIENCE AND TECHNOLOGY, 2012, 65 (02) : 353 - 360
  • [7] Effects of alternating and direct current in electrocoagulation process on the removal of cadmium from water
    Vasudevan, Subramanyan
    Lakshmi, Jothinathan
    Sozhan, Ganapathy
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 192 (01) : 26 - 34
  • [8] Effects of alternating current (AC) and direct current (DC) in electrocoagulation process for the removal of iron from water
    Vasudevan, Subramanyan
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2012, 90 (05): : 1160 - 1169
  • [9] Removal of copper from water by electrocoagulation process—effect of alternating current (AC) and direct current (DC)
    Ramakrishnan Kamaraj
    Pandian Ganesan
    Jothinathan Lakshmi
    Subramanyan Vasudevan
    Environmental Science and Pollution Research, 2013, 20 : 399 - 412
  • [10] Treatment of Brewery Wastewater with Electrocoagulation: Improving the Process Performance by Using Alternating Pulse Current
    Eyvaz, Murat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (06): : 4988 - 5008