Intraoperative microkeratome complications in 47,094 laser in situ keratomileusis surgeries

被引:0
|
作者
Nakano, K [1 ]
Nakano, E [1 ]
Oliveira, M [1 ]
Portellinha, W [1 ]
Alvarenga, L [1 ]
机构
[1] Excimer Laser Santa Cruz, Sao Paulo, Brazil
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: We evaluated the incidence and intraoperative microkeratome-related complications in laser in situ keratomileusis (LASIK). METHODS: We present non-randomized, retrospective, comparative, interventional case series. We reviewed the records of patients who underwent LASIK from August 2000 to March 2004 at Excimer Laser Santa Cruz, Sao Paulo, Brazil (47,094 eyes). We identified 369 eyes (0.0078%) with an intraoperative complication. Data were collected regarding microkeratome, average keratometric power, and type of complication. RESULTS: The Hansatome microkeratome was the most common microkeratome used (34,182 eyes; 73%), followed by the Automated Corneal ShaperACS (11,164 eyes, 24%) and the Nidek MK-2000 (1748 eyes, 3.7%). Intraoperative complications were more common with the ACS (1.26%) than with the Hansatome (0.63%) and MK-2000 (0.63%) (P < .001; P = .03; respectively). Complications included incomplete flaps (0.23%), buttonholes (0.13%), thin flaps (0.08%), and free flaps (0.08%). Buttonholes were more frequent with the ACS (0.34%) than with the Hansatome (0.06%) (P < .001) and free flaps were more common with the ACS (0.20%) and MK-2000 (0.29%) than with the Hansatome (0.04%) (P< .001). Keratometric power of eyes with intraoperative complications was significantly higher in the ACS group compared to the Hansatome group. CONCLUSIONS: Intraoperative complications were more common with the ACS than with the Hansatome or MK-2000. Buttonholes were most frequent with the ACS, and the Hansatome had the lowest incidence of free flaps.
引用
收藏
页码:S723 / S726
页数:4
相关论文
共 50 条
  • [11] Intraoperative flap complications in laser in situ keratomileusis with two types of microkeratomes
    Al-Mezaine, Hani S.
    Al-Amro, Saleh A.
    Al-Obeidan, Saleh
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2011, 25 (03) : 239 - 243
  • [12] Femtosecond Laser vs Mechanical Microkeratome for Hyperopic Laser In Situ Keratomileusis
    Gil-Cazorla, Raquel
    Teus, Miguel A.
    de Benito-Llopis, Laura
    Mikropoulos, Dimitrios G.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (01) : 16 - 21
  • [13] Comparison of the IntraLase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis
    Lim, Taehyung
    Yang, Sungjae
    Kim, Myoung Joon
    Tchah, Hungwon
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 833 - 839
  • [14] Corneal flap assessment with Rondo microkeratome in laser in situ keratomileusis
    Paschalis, Eleftherios I.
    Aristeidou, Antonis P.
    Foudoulakis, Nikitas C.
    Razis, Lambros A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (02) : 289 - 295
  • [15] Anatomic factors affecting microkeratome placement in laser in situ keratomileusis
    Booranapong, W
    Malathum, P
    Slade, SG
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09): : 1319 - 1325
  • [16] Corneal flap assessment with Rondo microkeratome in laser in situ keratomileusis
    Eleftherios I. Paschalis
    Antonis P. Aristeidou
    Nikitas C. Foudoulakis
    Lambros A. Razis
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 289 - 295
  • [17] Intraoperative and postoperative complications after laser in situ keratomileusis (LASIK)Intraoperative und postoperative Komplikationen
    Heike Petersen
    Theo Seiler
    Der Ophthalmologe, 1999, 96 : 240 - 247
  • [18] Tear Menisci After Laser In Situ Keratomileusis With Mechanical Microkeratome and Femtosecond Laser
    Xie, Wenjia
    Zhang, Dong
    Chen, Jia
    Liu, Jing
    Yu, Ye
    Hu, Liang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (09) : 5806 - 5812
  • [19] Femtosecond-Assisted Laser in situ Keratomileusis with de novo Flap Creation Following Previous Microkeratome Laser in situ Keratomileusis
    Rush, Sloan W.
    Rush, Ryan B.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 1813 - 1818
  • [20] Complications of laser in situ keratomileusis (LASIK)
    Tabbara, KF
    El-Sheikh, HF
    Vera-Cristo, CL
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (02) : 139 - 146