A new application of micellar liquid chromatography in the determination of free ampicillin concentration in the drug-human serum albumin standard solution in comparison with the adsorption method

被引:12
|
作者
Stepnik, Katarzyna E. [1 ]
Malinowska, Irena [1 ]
Maciejewska, Malgorzata [2 ]
机构
[1] Marie Curie Sklodowska Univ, Dept Planar Chromatog, Chair Phys Chem, Fac Chem, M Curie Sktodowska Sq 3, PL-20031 Lublin, Poland
[2] Marie Curie Sklodowska Univ, Dept Polymer Chem, Fac Chem, Gliniana St 33, PL-20614 Lublin, Poland
关键词
Free drug concentration; Human serum albumin; Drug-protein complex; Micellar liquid chromatography; Drug discovery; PLASMA-PROTEIN-BINDING; COLUMN SELECTIVITY; EQUILIBRIUM DIALYSIS; ALPHA-1-ACID GLYCOPROTEIN; MOBILE PHASES; FREE FRACTION; ULTRAFILTRATION; INJECTION; PREDICTION; BEHAVIOR;
D O I
10.1016/j.talanta.2016.02.045
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of free drug concentration is a very important issue in the field of pharmacology because only the unbound drug fraction can achieve a pharmacological effect. Due to the ability to solubilize many different compounds in micellar aggregates, micellar liquid chromatography (MLC) can be used for direct determination of free drug concentration. Proteins are not retained on the stationary phase probably due to the formation of protein - surfactant complexes which are excluded from the pores of stationary phase. The micellar method is simple and fast. It does not require any pre-preparation of the tested samples for analysis. The main aim of this paper is to demonstrate a completely new applicability of the analytical use of MLC concerning the determination of free drug concentration in the standard solution of human serum albumin. The well-known adsorption method using RP-HPLC and the spectrophotometric technique was applied as the reference method. The results show that the free drug concentration value obtained in the MLC system (based on the RP 8 stationary phase and CTAB) is similar to that obtained by the adsorption method: both RP-HPLC (95.83 mu g mL(-1), 79.86% of free form) and spectrophotometry (95.71 mu g mL(-1), 79.76%). In the MLC the free drug concentration was 93.98 mu g mL(-1) (78.3%). This indicates that the obtained results are within the analytical range of % of free ampicillin fraction and the MLC with direct sample injection can be treated like a promising method for the determination of free drug concentration. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [21] Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods
    Lee, Hwa Shim
    Lee, Jong Man
    Park, Sang Ryoul
    Lee, Je Hoon
    Kim, Yong Goo
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (06): : 1698 - 1702
  • [22] A simple, rapid and reliable liquid chromatography-mass spectrometry method for determination of methotrexate in human plasma and its application to therapeutic drug monitoring
    Wu, Dan
    Wang, Yixuan
    Sun, Yan
    Ouyang, Nian
    Qian, Jun
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (08) : 1197 - 1202
  • [23] New validated liquid chromatography-tandem mass spectrometry method for the determination of Dacomitinib in human plasma and its application to a pharmacokinetic study
    Gupta, Tinku
    Sahoo, NaliniKanta
    Rambabu, Maddela
    Praveen, M.
    Charde, Shrikant
    Sahu, Madhusmita
    Chakrabarti, Prasun
    Hung, Bui Thanh
    Margala, Martin
    Unhelkar, Bhuvan
    Narayanankutty, Arunaksharan
    SEPARATION SCIENCE PLUS, 2024, 7 (02)
  • [24] A new high-performance liquid chromatography using isocratic condition eluent for determination of four bilirubins in human serum as comparative method.
    Osawa, S
    Yoshida, T
    Nomura, F
    Sugo, S
    Yamaoka, Y
    CLINICAL CHEMISTRY, 2005, 51 : A30 - A30
  • [25] Simultaneous separation and determination of vancomycin and its crystalline degradation products in human serum by ultra high performance liquid chromatography tandem mass spectrometry method and its application in therapeutic drug monitoring
    Fan, Yaxin
    Peng, Xiaolin
    Wu, Hailan
    Liang, Xiaoyu
    Chen, Yuancheng
    Guo, Beining
    Zhang, Jing
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (21) : 3987 - 3994
  • [26] DIRECT DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING ZWITTERIONIC MICELLAR MOBILE-PHASE - COMPARISON WITH AN ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE
    HABEL, D
    GUERMOUCHE, S
    GUERMOUCHE, MH
    ANALYST, 1993, 118 (12) : 1511 - 1513
  • [27] An improved fluorometric high-performance liquid chromatography method for sialic acid determination: An internal standard method and its application to sialic acid analysis of human apolipoprotein E
    Ito, M
    Ikeda, K
    Suzuki, Y
    Tanaka, K
    Saito, M
    ANALYTICAL BIOCHEMISTRY, 2002, 300 (02) : 260 - 266
  • [28] Development of a new ultra-high performance liquid chromatography-tandem mass spectrometry method for determination of ambroxol hydrochloride in serum with pharmacokinetic application
    Vujovic, Maja M.
    Jokanovic, Milan
    Nikolic, Goran M.
    HEMIJSKA INDUSTRIJA, 2016, 70 (04) : 409 - 418
  • [29] USE OF A HUMAN SERUM ALBUMIN-BASED STATIONARY PHASE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AS A TOOL FOR THE RAPID-DETERMINATION OF DRUG PLASMA-PROTEIN BINDING
    NOCTOR, TAG
    DIAZPEREZ, MJ
    WAINER, IW
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1993, 82 (06) : 675 - 676
  • [30] A Rapid Method for Determination of Serum Methotrexate Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Therapeutic Drug Monitoring
    Tripathy, Naresh Kumar
    Mishra, Shravan Kumar
    Nathan, Gopi
    Srivastava, Shreya
    Gupta, Anshul
    Lingaiah, Raghavendra
    JOURNAL OF LABORATORY PHYSICIANS, 2023, 15 (03) : 344 - 353