Voltammetric determination of salbutamol on a glassy carbon electrode coated with a nanomaterial thin film

被引:15
|
作者
Wei, Yingliang [1 ,2 ]
Zhang, Qing [1 ]
Shao, Chen [2 ]
Li, Chao [2 ]
Zhang, Luping [2 ]
Li, Xianli [2 ]
机构
[1] Luoyang Inst Sci & Technol, Dept Environm Engn & Chem, Luoyang 471023, Peoples R China
[2] Zhengzhou Univ Light Ind, Dept Mat & Chem Engn, Zhengzhou 450002, Peoples R China
基金
中国国家自然科学基金;
关键词
DOPAMINE;
D O I
10.1134/S1061934810040106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and convenient electrochemical method is described for the determination of salbutamol based on multi-carbon nanotubes (MWNT) film coated glassy carbon electrode (GCE). The electrochemical behavior of salbutamol at this modified electrode was studied by square wave voltammetry, which indicated that the oxidation peak potential of salbutamol shifted on 40 mV to less positive potential and the peak current increased 4.5 fold, in contrast to that at a bare electrode. Various experimental parameters such as pH value of supporting electrolyte, the amount of modifier, and accumulation time were optimized. Under optimal measurement conditions, there is a good linear relationship between the peak current (I (pa)) and salbutamol concentration in the range from 8.0 x 10(-7) to 1.0 x 10(-5) M, and the detection limit is 2.0 x 10(-7) M (S/N = 3) at 2 min accumulation. The method has been successfully employed to detect salbutamol in pharmaceutical formulations.
引用
收藏
页码:398 / 403
页数:6
相关论文
共 50 条
  • [1] Voltammetric determination of salbutamol on a glassy carbon electrode coated with a nanomaterial thin film
    Yingliang Wei
    Qing Zhang
    Chen Shao
    Chao Li
    Luping Zhang
    Xianli Li
    Journal of Analytical Chemistry, 2010, 65 : 398 - 403
  • [2] Electrochemical reduction and voltammetric determination of metronidazole at a nanomaterial thin film coated glassy carbon electrode
    Lu, SF
    Wu, KB
    Dang, XP
    Hu, SS
    TALANTA, 2004, 63 (03) : 653 - 657
  • [3] Application of glassy carbon electrode modified with a carbon nanoparticle/melamine thin film for voltammetric determination of raloxifene
    Shahrokhian, Saeed
    Ghalkhani, Masoumeh
    Balotf, Hamed
    Salimian, Razieh
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 : 126 - 133
  • [4] Simple Voltammetric Determination of Iron in Ethanol and Biodiesel Using a Bismuth Film Coated Glassy Carbon Electrode
    Almeida, Joseany M. S.
    Ribeiro, Ana Beatriz P.
    Toloza, Carlos A. T.
    Alves, Ismael C. B.
    Santos, Jose Ribamar N.
    De Azevedo, Lorena C. M.
    Aucelio, Ricardo Q.
    Marques, Aldalea L. B.
    ANALYTICAL LETTERS, 2022, 55 (15) : 2325 - 2346
  • [5] Mercury Thin Film at Glassy Carbon Electrode for Adsorptive Stripping Voltammetric Determination of Captopril in Pharmaceutical Samples
    Zargar, Behrooz
    Parham, Hooshang
    Hatamie, Amir
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (03): : 344 - 357
  • [6] Anodic stripping voltammetric determination of gold on a polyvinylferrocene coated glassy carbon electrode
    Kavanoz, M
    Gülce, H
    Yildiz, A
    TURKISH JOURNAL OF CHEMISTRY, 2004, 28 (03) : 287 - 297
  • [7] Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Gutz, IGR
    LaScalea, MA
    ELECTROANALYSIS, 1997, 9 (02) : 110 - 114
  • [8] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    ANALYST, 2002, 127 (01) : 129 - 134
  • [9] VOLTAMMETRIC DETERMINATION OF NEPTUNIUM AT GLASSY CARBON ELECTRODE
    PLOCK, CE
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1968, 18 (03): : 289 - &
  • [10] Voltammetric determination of paracetamol on the glassy carbon electrode
    毕淑云
    王桂芬
    朴元哲
    王大力
    殷晓萍
    延边大学学报(自然科学版), 2000, (02) : 110 - 112