Wet gas overreading characteristics of a long-throat Venturi at high pressure based on CFD

被引:6
|
作者
Xu, Ying [1 ,2 ]
Gao, Lu [1 ,2 ]
Zhao, Yi [3 ]
Wang, Huaxiang [1 ,2 ]
机构
[1] Key Lab Proc Measurement & Control Tianjin, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Elect Engn & Automat, Tianjin 300072, Peoples R China
[3] Tianjin Inst Metrol Supervis & Testing, Tianjin 300192, Peoples R China
关键词
Nonstandard long-throat Venturi meter (LTVM); Wet gas; Computational fluid dynamics (CFD); Overreading (OR) correlation; Equivalent droplet diameter; FLOW;
D O I
10.1016/j.flowmeasinst.2014.09.004
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Based on the operational conditions of the PetroChina Southwest Oil & Gas well field, this study aims to explore the wet gas flow overreading (OR) characteristics of a nonstandard long-throat Venturi by the means of computational fluid dynamics (CFD) technique. The studied prototype structure size is an inner diameter of 50 mm, a diameter ratio of 0.4 and a throat length of 50 mm. According to the field experiment, the simulation pressure is 3 MPa gauge. Through a comparative study of the multiphase flow models and turbulence models, combined with the analysis of the Baker's flow regime and interparticle space under the field conditions, this paper eventually employed DPM model and Eulerian model for wet gas simulation, respectively, and RSM for turbulence model. An equivalent droplet diameter adjustment method was implemented to improve the precision of prediction. During post-processing, the liquid phase distributions and the wall pressure profiles were investigated. The numerical results indicate that the differential pressure in convergent section of long-throat Venturi by using DPM model is less than that by using Eulerian model, and the differential pressures in the divergent section by using the two models are analogous. Afterwards, the OR prediction correlations based on the differential pressure ratio method were proposed, and then compared and validated by the industrial field tests. The root mean square errors (RMSE) and the average relative errors predicted by Eulerian model were 4.24% and 3.78%, 5.69% and 5.01% by using DPM model, respectively. In conclusion, Eulerian model is more suitable for wet gas flow prediction. And some advice on the improvement of the multiphase flow simulation is provided to get a more preferable performance in wet gas flow prediction. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 50 条
  • [1] Study on the similarity of wet gas pressure drop in long-throat Venturi
    Wu, Haitao
    Xu, Ying
    Wang, Jinghan
    Zhang, Tao
    Wang, Huaxiang
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 68
  • [2] Wet gas metering by using a long-throat Venturi meter
    Xu, Lijun
    Li, Hui
    Xu, Jian
    SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [3] Wet gas measurements of long-throat Venturi Tube based on forced annular flow
    Zheng, Weibiao
    Liang, Ruomiao
    Zhang, Xingkai
    Liao, Ruiquan
    Wang, Dong
    Huang, Lamei
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 81
  • [4] A CFD study of the effect of venturi geometry on high pressure wet gas metering
    Perumal, Kumar
    Krishnan, Jagannathan
    INTERNATIONAL JOURNAL OF OIL GAS AND COAL TECHNOLOGY, 2013, 6 (05) : 549 - 566
  • [5] Numerical simulation on high pressure wet gas flowmetering overreading characteristics of verturi tube
    Xu, Ying
    Duan, Yu-Han
    Zhao, Yi
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2012, 45 (03): : 221 - 227
  • [6] CFD Simulation of Throat Pressure in Venturi Scrubber
    Ali, Majid
    Yan Changqi
    Sun Zhongning
    Wang Jianjun
    Rasool, Athar
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 3630 - 3634
  • [7] A Wet Gas Metering System Based on the Extended-Throat Venturi Tube
    Xue, Haobai
    Yu, Peining
    Zhang, Maomao
    Zhang, Haifeng
    Wang, Encheng
    Wu, Guozhu
    Li, Yi
    Zheng, Xiangyuan
    SENSORS, 2021, 21 (06) : 1 - 19
  • [8] Study on the Key Factors of Wet Gas Metering Overreading in Standard Venturi Tube Base on DPM
    Xu, Ying
    Zhao, Yi
    Long, Zhenghai
    ADVANCES IN MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 220-223 : 1693 - 1697
  • [9] Experimental study on the influence of longer throat Venturi tube pressure tappings position to wet gas measurement model
    Xu, Y. (xuying@tju.edu.cn), 1600, Chinese Mechanical Engineering Society (50):
  • [10] Analysis of high pressure tests on wet gas flow metering with a Venturi meter
    Gajan, P.
    Decaudin, Q.
    Couput, J. P.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 44 : 126 - 131