Analysis of high pressure tests on wet gas flow metering with a Venturi meter

被引:15
|
作者
Gajan, P. [1 ]
Decaudin, Q. [2 ]
Couput, J. P. [2 ]
机构
[1] Off Natl Etud & Rech Aerosp, F-31055 Toulouse, France
[2] TOTAL, F-64018 Pau, France
关键词
Wet gas; Venturi meter; Modelling; High pressure; ANNULAR LIQUID-FILM; DROPLET ENTRAINMENT; 2-PHASE FLOW; DEPOSITION; REGIME;
D O I
10.1016/j.flowmeasinst.2014.12.004
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This work deals with the flow metering of wet gas issued from high pressure natural reservoirs. Some recent results obtained from tests performed on the CEESI facilities are presented. They are performed at 75 bar with 0.6 beta ratio Venturi meter installed in horizontal pipe configuration. Correction factors obtained are compared to predictions deduced from the flow modelling inside of the meter. These results are analysed in order to explain the agreements or disagreements obtained between the experiments and the flow modelling. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 50 条
  • [1] Wet gas metering with a horizontally mounted Venturi meter
    Steven, RN
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 12 (5-6) : 361 - 372
  • [2] On fluctuation of the dynamic differential pressure signal of Venturi meter for wet gas metering
    Xu, LJ
    Xu, H
    Dong, F
    Zhang, T
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2003, 14 (4-5) : 211 - 217
  • [3] Venturi meter performance in wet gas flow
    DeLeeuw, H
    [J]. 8TH INTERNATIONAL CONFERENCE ON MULTIPHASE '97 - HOW DEEP? HOW FAR? HOW SOON?, 1997, (24): : 567 - 582
  • [4] Wet Gas Metering Using a Venturi-meter and Neural Networks
    Xu, Lijun
    Li, Hui
    Tang, Shaliang
    Tan, Cheng
    Hu, Bo
    [J]. 2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 761 - +
  • [5] Wet gas metering by using a long-throat Venturi meter
    Xu, Lijun
    Li, Hui
    Xu, Jian
    [J]. SEVENTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY: SENSORS AND INSTRUMENTS, COMPUTER SIMULATION, AND ARTIFICIAL INTELLIGENCE, 2008, 7127
  • [6] A CFD study of the effect of venturi geometry on high pressure wet gas metering
    Perumal, Kumar
    Krishnan, Jagannathan
    [J]. INTERNATIONAL JOURNAL OF OIL GAS AND COAL TECHNOLOGY, 2013, 6 (05) : 549 - 566
  • [7] Numerical investigation of wet gas flow in Venturi meter
    He, Denghui
    Bai, Bofeng
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2012, 28 : 1 - 6
  • [8] Wet Gas Metering Using a Venturi-Meter and Support Vector Machines
    Xu, Lijun
    Tang, Shaliang
    [J]. I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1125 - 1129
  • [9] A new correlation of wet gas flow for low pressure with a vertically mounted Venturi meter
    Pan, Yanzhi
    Hong, Yi
    Sun, Qin
    Zheng, Ziqiong
    Wang, Dong
    Niu, Pengman
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 70
  • [10] Wet gas flow modeling for a vertically mounted Venturi meter
    Xu, Lijun
    Zhou, Wanlu
    Li, Xiaomin
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (04)