Sparse precontrast T1 mapping for high-resolution whole-brain DCE-MRI

被引:3
|
作者
Zhu, Zhibo [1 ]
Lebel, R. Marc [2 ,3 ]
Bliesener, Yannick [1 ]
Acharya, Jay [4 ]
Frayne, Richard [3 ,5 ]
Nayak, Krishna S. [1 ,4 ]
机构
[1] Univ Southern Calif, Ming Hsieh Dept Elect & Comp Engn, 3740 McClintock Ave,EEB 412, Los Angeles, CA 90089 USA
[2] Gen Elect Healthcare, Calgary, AB, Canada
[3] Univ Calgary, Hotchkiss Brain Inst, Radiol & Clin Neurosci, Calgary, AB, Canada
[4] Univ Southern Calif, Dept Radiol, Los Angeles, CA 90089 USA
[5] Foothills Med Ctr, Seaman Family MR Res Ctr, Calgary, AB, Canada
基金
美国国家卫生研究院;
关键词
brain tumor; model-based reconstruction; quantitative dynamic contrast-enhanced-magnetic resonance imaging (DCE-MRI); sparse sampling; T-1; mapping; CONTRAST-ENHANCED MRI; ARTERIAL INPUT FUNCTION; VARIABLE FLIP ANGLE; MULTIPLE-SCLEROSIS; KINETIC-PARAMETERS; PERMEABILITY; TRACER; T1; GLIOMA; MODEL;
D O I
10.1002/mrm.28849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop and evaluate an efficient precontrast T-1 mapping technique suitable for quantitative high-resolution whole-brain dynamic contrast-enhanced-magnetic resonance imaging (DCE-MRI). Methods: Variable flip angle (VFA) T-1 mapping was considered that provides 1 x 1 x 2 mm(3) resolution to match a recent high-resolution whole-brain DCE-MRI protocol. Seven FAs were logarithmically spaced from 1.5 degrees to 15 degrees. T-1 and M-0 maps were estimated using model-based reconstruction. This approach was evaluated using an anatomically realistic brain tumor digital reference object (DRO) with noise-mimicking 3T neuroimaging and fully sampled data acquired from one healthy volunteer. Methods were also applied on fourfold prospectively undersampled VFA data from 13 patients with high-grade gliomas. Results: T-1-mapping precision decreased with undersampling factor R, althoughwhereas bias remained small before a critical R. In the noiseless DRO, T-1 bias was <25 ms in white matter (WM) and <11 ms in brain tumor (BT). T-1 standard deviation (SD) was <119.5 ms in WM (coefficient of variation [COV] similar to 11.0%) and <253.2 ms in BT (COV similar to 12.7%). In the noisy DRO, T-1 bias was <50 ms in WM and <30 ms in BT. For R <= 10, T-1 SD was <107.1 ms in WM (COV similar to 9.9%) and <240.9 ms in BT (COV similar to 12.1%). In the healthy subject, T-1 bias was <30 ms for R <= 16. At R = 4, T-1 SD was 171.4 ms (COV similar to 13.0%). In the prospective brain tumor study, T-1 values were consistent with literature values in WM and BT. Conclusion: High-resolution whole-brain VFA T-1 mapping is feasible with sparse sampling, supporting its use for quantitative DCE-MRI.
引用
收藏
页码:2234 / 2249
页数:16
相关论文
共 50 条
  • [41] High-resolution T1 MRI via renally clearable dextran nanoparticles with an iron oxide shell
    Tae-Hyun Shin
    Pan Ki Kim
    Sunghwi Kang
    Jiyong Cheong
    Soojin Kim
    Yongjun Lim
    Wookjin Shin
    Joon-Yong Jung
    Jungsu D. Lah
    Byoung Wook Choi
    Jinwoo Cheon
    Nature Biomedical Engineering, 2021, 5 : 252 - 263
  • [42] Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart
    Messroghli, DR
    Radjenovic, A
    Kozerke, S
    Higgins, DM
    Sivananthan, MU
    Ridgway, JP
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 141 - 146
  • [43] Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T
    Vidorreta, Marta
    Balteau, Evelyne
    Wang, Ze
    De Vita, Enrico
    Pastor, Maria A.
    Thomas, David L.
    Detre, John A.
    Fernandez-Seara, Maria A.
    NMR IN BIOMEDICINE, 2014, 27 (11) : 1387 - 1396
  • [44] T1 measurement of flowing blood and arterial input function determination for quantitative 3D T1-weighted DCE-MRI
    Cheng, Hai-Ling Margaret
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (05) : 1073 - 1078
  • [45] Mapping glutamate in subcortical brain structures using high-resolution GluCEST MRI
    Cai, Kejia
    Singh, Anup
    Roalf, David R.
    Nanga, Ravi Prakash Reddy
    Haris, Mohammad
    Hariharan, Hari
    Gur, Ruben
    Reddy, Ravinder
    NMR IN BIOMEDICINE, 2013, 26 (10) : 1278 - 1284
  • [46] Accelerated 3D whole-brain T1, T2, and proton density mapping: feasibility for clinical glioma MR imaging
    Pirkl, Carolin M.
    Nunez-Gonzalez, Laura
    Kofler, Florian
    Endt, Sebastian
    Grundl, Lioba
    Golbabaee, Mohammad
    Gomez, Pedro A.
    Cencini, Matteo
    Buonincontri, Guido
    Schulte, Rolf F.
    Smits, Marion
    Wiestler, Benedikt
    Menze, Bjoern H.
    Menzel, Marion I.
    Hernandez-Tamames, Juan A.
    NEURORADIOLOGY, 2021, 63 (11) : 1831 - 1851
  • [47] Accelerated 3D whole-brain T1, T2, and proton density mapping: feasibility for clinical glioma MR imaging
    Carolin M. Pirkl
    Laura Nunez-Gonzalez
    Florian Kofler
    Sebastian Endt
    Lioba Grundl
    Mohammad Golbabaee
    Pedro A. Gómez
    Matteo Cencini
    Guido Buonincontri
    Rolf F. Schulte
    Marion Smits
    Benedikt Wiestler
    Bjoern H. Menze
    Marion I. Menzel
    Juan A. Hernandez-Tamames
    Neuroradiology, 2021, 63 : 1831 - 1851
  • [48] Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study
    Bane, Octavia
    Hectors, Stefanie J.
    Wagner, Mathilde
    Arlinghaus, Lori L.
    Aryal, Madhava P.
    Cao, Yue
    Chenevert, Thomas L.
    Fennessy, Fiona
    Huang, Wei
    Hylton, Nola M.
    Kalpathy-Cramer, Jayashree
    Keenan, Kathryn E.
    Malyarenko, Dariya I.
    Mulkern, Robert V.
    Newitt, David C.
    Russek, Stephen E.
    Stupic, Karl F.
    Tudorica, Alina
    Wilmes, Lisa J.
    Yankeelov, Thomas E.
    Yen, Yi-Fei
    Boss, Michael A.
    Taouli, Bachir
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2564 - 2575
  • [49] Primary brain lymphoma and glioblastoma: evaluation of DCE T1 and DSC T2 MRI perfusion findings
    Soydan, Hamza
    Soezmen Ciliz, Deniz
    Cesur, Turay
    Tezgor Aksakal, Eda
    ACTA RADIOLOGICA, 2024, 65 (07) : 800 - 807
  • [50] INVIVO HIGH-RESOLUTION VOLUME-SELECTED PROTON SPECTROSCOPY AND T1 MEASUREMENTS IN THE DOG BRAIN
    GALLOWAY, GJ
    FIELD, J
    ROSE, SE
    HASELER, LJ
    BROOKS, WM
    BRERETON, IM
    BORE, PJ
    CROZIER, S
    DODDRELL, DM
    MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (02) : 288 - 295