Spatiotemporal optical coherence (STOC) manipulation suppresses coherent cross-talk and low-order geometrical aberrations in full-field swept-source optical coherence tomography

被引:0
|
作者
Borycki, Dawid [1 ]
Sudyka, Julia [1 ]
Wojtkowski, Maciej [1 ,2 ]
机构
[1] Polish Acad Sci, Inst Phys Chem, Kasprzaka 44-52, PL-01224 Warsaw, Poland
[2] Nicolaus Copernicus Univ, Fac Phys Astron & Informat, Grudziadzka 5, PL-87100 Torun, Poland
关键词
SPATIALLY INCOHERENT ILLUMINATION;
D O I
10.1117/12.2526604
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Full-field swept-source optical coherence tomography (FF-SS-OCT) achieves high resolution imaging with wide-field illumination and parallel Fourier-domain detection. However, FF-SS-OCT is strongly susceptible to the cross-talk-generated noise from spatially coherent lasers. Here, we demonstrate how to overcome this problem with spatiotemporal optical coherence (STOC) manipulation. In STOC the time-varying inhomogeneous phase masks modulate the incident light. We show that by properly adjusting these phase masks, the spatial coherence can be reduced. As a result, the imaging system becomes spatially incoherent. Thus, the cross-talk-generated noise as well as the low-order geometrical aberrations can be suppressed. STOC approach is validated by imaging 1951 USAF resolution test chart covered by diffuser, scattering phantom and the rat skin ex vivo.
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Effect of Temporal Decentration of Orthokeratologic Lens on Corneal Aberrations in Swept-source Optical Coherence Tomography
    Heo, Jung Sun
    Moon, Nam Ju
    Kim, Kyoung Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (05): : 309 - 319
  • [32] Three-dimensional shape measurement of micro-lens arrays using full-field swept-source optical coherence tomography
    Anna, Tulsi
    Shakher, Chandra
    Mehta, Dalip Singh
    OPTICS AND LASERS IN ENGINEERING, 2010, 48 (11) : 1145 - 1151
  • [33] Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry
    Hoffer, Kenneth J.
    Hoffmann, Peter C.
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1165 - 1172
  • [34] In Vitro Retinal Imaging with Full Field Swept Source Optical Coherence Tomography
    Fergusson, James
    Povazay, Boris
    Hofer, Bernd
    Drexler, Wolfgang
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [35] Line field swept source optical coherence tomography system with compensation of chromatic aberrations
    Gurov, Igor
    Pimenov, Aleksei
    Skakov, Pavel
    SARATOV FALL MEETING 2018: LASER PHYSICS, PHOTONIC TECHNOLOGIES AND MOLECULAR MODELING, 2019, 11066
  • [36] Wide field of view swept-source optical coherence tomography for peripheral retinal disease
    McNabb, Ryan P.
    Grewal, Dilraj S.
    Mehta, Rajvi
    Schuman, Stefanie G.
    Izatt, Joseph A.
    Mahmoud, Tamer H.
    Jaffe, Glenn J.
    Mruthyunjaya, Prithvi
    Kuo, Anthony N.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (10) : 1377 - 1382
  • [37] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Rongrong Gao
    Hao Chen
    Giacomo Savini
    Yaxin Miao
    Xiaorui Wang
    Jing Yang
    Weiqi Zhao
    Qinmei Wang
    Jinhai Huang
    Scientific Reports, 7
  • [38] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Gao, Rongrong
    Chen, Hao
    Savini, Giacomo
    Miao, Yaxin
    Wang, Xiaorui
    Yang, Jing
    Zhao, Weiqi
    Wang, Qinmei
    Huang, Jinhai
    SCIENTIFIC REPORTS, 2017, 7
  • [39] Biometry with a new swept-source optical coherence tomography biometer: Repeatability and agreement with an optical low-coherence reflectometry device
    Kurian, Mathew
    Negalur, Nikhil
    Das, Sudeep
    Puttaiah, Narendra K.
    Haria, Dhawal
    Tejal, S. J.
    Thakkar, Maithil M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 577 - 581
  • [40] Repeatability of a fully automated swept-source optical coherence tomography biometer and agreement with a low coherence reflectometry biometer
    Dominguez-Vicent, Alberto
    Venkataraman, Abinaya Priya
    Dalin, Amanda
    Brautaset, Rune
    Montes-Mico, Robert
    EYE AND VISION, 2023, 10 (01)