Impact of Cochlear Implant Array Placement on Speech Perception

被引:5
|
作者
Lo Russo, Francesco [1 ]
Conte, Giorgio [1 ]
Di Berardino, Federica [2 ]
Cavicchiolo, Sara [2 ]
Casale, Silvia [1 ]
Caschera, Luca [1 ]
Lombardi, Luciano [1 ]
Triulzi, Fabio [1 ,3 ]
Zanetti, Diego [2 ]
机构
[1] Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dept Neuroradiol, Via Francesco Sforza 28, I-20122 Milan, Italy
[2] Univ Milan, Fdn IRCCS Ca Granda Osped Maggiore Policlin, Dept Clin Sci & Community Hlth, Audiol Unit, Milan, Italy
[3] Univ Milan, Dept Pathophysiol & Transplantat, Milan, Italy
关键词
Flat panel CT; Angular insertion depth; Linear insertion depth; Sensorineural hearing loss; Surgical insertion depth; Wrapping factor; RESOLUTION COMPUTED-TOMOGRAPHY; FLAT-PANEL CT; ELECTRODE POSITION; CHANNEL INTERACTION; INSERTION DEPTH; RECOGNITION; HEARING; CII;
D O I
10.1007/s00062-021-01046-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To assess the role of flat panel computed tomography (FPCT) in the evaluation of cochlear implant (CI) electrode position and its relation to speech perception. Methods From March 2015 to March 2019, we retrospectively enrolled deaf subjects >= 18 years who underwent unilateral CI by one surgeon, imaged with FPCT and assessed with disyllabic words score before CI and at 6 months of follow-up. We calculated the disyllabic score difference before CI and after CI (Delta SDS) and divided the subjects in favorable and unfavorable outcome groups using the median Delta SDS as a cutoff. We compared the demographic, clinical, electrode characteristics, and the CI positioning variables scalar position, surgical insertion depth (SID), linear insertion depth (LID), angular insertion depth (AID) and wrapping factor (WF). Results We studied 50 subjects (F/M = 27/23; median age = 60.5 years, IQR: 50-70 years). The median Delta SDS was 80% (interquartile range [IQR]: 60-100%) in quiet and 80% (IQR: 47.5-100%) in noise. Of the subjects 23 demonstrated a favorable outcome and had earlier age at CI (median 52 years; IQR 45-67 years versus median 62 years; IQR: 56-71 years p = 0.032) and a significantly higher SID (median: 4.02 mm IQR: 3.00-5.35 mm versus median: 2.94 mm IQR: 2.06-3.90 mm; p = 0.029). No difference was found for LID (p = 0.977), AID (p = 0.302), and WF (p = 0.224). A logistic regression model built with the age at CI, number of CI electrodes, and the SID was significant chi 2 ((df = 3, N = 50) = 14.517, p = 0.002). The model explained 33.7% (Nagelkerke R2) of Delta SDS variance and correctly classified 76% of the cases. Conclusion The SID measured by FPCT predicts the Delta SDS at 6 months follow-up, alongside with age at implantation and number of CI electrodes.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 50 条
  • [41] EVALUATION OF SPEECH-PERCEPTION RESULTS IN COCHLEAR IMPLANT PATIENTS
    EISENWORT, B
    BURIAN, K
    FOLIA PHONIATRICA, 1988, 40 (02): : 74 - 81
  • [42] Evaluation methods of speech perception ability through cochlear implant
    Shiroma, M
    Iwaki, T
    Kawano, J
    Kubo, T
    Funasaka, S
    COCHLEAR IMPLANT AND RELATED SCIENCES UPDATE, 1997, 52 : 220 - 223
  • [43] Speech Perception Performance of Double Array Multichannel Cochlear Implant Users With Standard and Duplicated Maps in Each of the Arrays
    Bento, Ricardo Ferreira
    Schmidt Goffi-Gomez, Maria Valeria
    Tsuji, Robinson Koji
    de Oliveira Fonseca, Anna Carolina
    Ikari, Liliane Satomi
    de Brito Neto, Rubens Vuono
    OTOLOGY & NEUROTOLOGY, 2013, 34 (02) : 245 - 250
  • [44] The impact of reverberation on speech intelligibility in cochlear implant recipients
    Kressner, Abigail Anne
    Westermann, Adam
    Buchholz, Jorg M.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2018, 144 (02): : 1113 - 1122
  • [45] Influence of the Cochlear Implant Electrode Array Placement on the Current Spread in the Cochlea
    Schaefer, Friederike
    Enke, Joerg
    Boehnke, Frank
    Hemmert, Werner
    Bai, Siwei
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 6145 - 6148
  • [46] Effects of residual speech and auditory deprivation on speech perception of adult cochlear implant recipients
    Derinsu, Ufuk
    Yuksel, Mustafa
    Gecici, Cennet Reyyan
    Ciprut, Ayca
    Akdeniz, Esra
    AURIS NASUS LARYNX, 2019, 46 (01) : 58 - 63
  • [47] Optimizing the perception of soft speech and speech in noise with the Advanced Bionics cochlear implant system
    Holden, Laura K.
    Reeder, Ruth M.
    Firszt, Jill B.
    Finley, Charles C.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2011, 50 (04) : 255 - 269
  • [48] Evaluation of the Effect of Musical Perception Activities on Speech Perception in Adult Cochlear Implant Users
    Mutlu, Barak
    Topcu, Merve Torun
    Yuksel, Mustafa
    Kalcioglu, Mahmut Tayyar
    TURKISH ARCHIVES OF OTORHINOLARYNGOLOGY, 2022, 60 (04) : 188 - 198
  • [49] Interleaved Acoustic Environments: Impact of an Auditory Scene Classification Procedure on Speech Perception in Cochlear Implant Users
    Eichenauer, Anja
    Baumann, Uwe
    Stoever, Timo
    Weissgerber, Tobias
    TRENDS IN HEARING, 2021, 25
  • [50] Impact of Reverberation on Speech Perception in Noise in Bimodal/Bilateral Cochlear Implant Users with and without Residual Hearing
    Koenig, Clara
    Baumann, Uwe
    Stoever, Timo
    Weissgerber, Tobias
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)