Near Infrared Spectroscopy Monitoring in the Pediatric Cardiac Catheterization Laboratory

被引:13
|
作者
Tanidir, Ibrahim Cansaran [1 ]
Ozturk, Erkut [1 ]
Ozyilmaz, Isa [1 ]
Saygi, Murat [1 ]
Kiplapinar, Neslihan [1 ]
Haydin, Sertac [2 ]
Guzeltas, Alper [1 ]
Odemis, Ender [1 ]
机构
[1] Istanbul Mehmet Akif Ersoy Thorac & Cardiovasc Su, Dept Pediat Cardiol, Istanbul, Turkey
[2] Istanbul Mehmet Akif Ersoy Thorac & Cardiovasc Su, Dept Pediat Cardiovasc Surg, Istanbul, Turkey
关键词
Children; Cardiac catheterization; Complication; Monitorization; Near-infrared spectroscopy; OXYGENATION; PARAMETERS;
D O I
10.1111/aor.12256
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Near-infrared spectroscopy (NIRS) is a noninvasive method used to evaluate tissue oxygenation. We evaluated the relationship between cerebral and renal NIRS parameters during transcatheter intervention and adverse events in the catheterization room. Between January 1 and May 31, 2012, 123 of 163 pediatric patients undergoing cardiac catheterization were followed by NIRS. All were monitored by electrocardiography, noninvasive blood pressure measurement, pulse oxymetry, initial and final blood lactate level measurement. The number of interventional procedures was 73 (59%). During the procedures, 39 patients experienced a total of 41 adverse events: 18 (19.5%) had desaturation, 10 (8.1%) arrhythmia, three (2.4%) had respiratory difficulty, six (4.8%) had a situation calling for cardiopulmonary resuscitation, three (2.4%) had anemia necessitating transfusion, and one (0.8%) had a cyanotic spell. Cranial NIRS values worsened in 12 (9.8%) and renal measurements worsened in 13 (12.5%) patients. The sensitivity and specificity of a 9% impairment of cranial values were 90 and 61%, respectively, while the corresponding calculations for a 21% fall in renal measurements were 54% sensitivity and 90% specificity. When arrhythmia developed, NIRS values fell simultaneously, while the development of a desaturation problem was heralded by NIRS falling 10-15 s earlier than changes in pulse oxymetry; on improving saturation, NIRS returned to earlier values 10-15 s before pulse oxymetry readings. NIRS monitoring may provide an early warning with regard to complications likely to develop during a procedure. A fall of 9% in cranial NIRS values, or of 21% in renal measurements, should raise clinician awareness.
引用
收藏
页码:838 / 844
页数:7
相关论文
共 50 条
  • [21] Near-Infrared Spectroscopy Monitoring in Pediatric Anesthesiology: A Pro-Con Discussion
    Rao, Anusha
    Gourkanti, Bharathi
    Van Helmond, Noud
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [22] The Cardiac Catheterization Laboratory
    Lopez, Pedro
    RADIOLOGIC TECHNOLOGY, 2023, 94 (05) : 372 - 378
  • [23] The utility of near infrared spectroscopy in pediatric epilepsy
    Gallagher, Anne
    JOURNAL OF PEDIATRIC EPILEPSY, 2013, 2 (01) : 87 - 92
  • [24] Near-infrared spectroscopy monitoring tissue oxygen saturation after cardiac surgery
    R Kopp
    S Rex
    K Dommann
    G Schälte
    G Dohmen
    G Marx
    R Rossaint
    Critical Care, 13 (Suppl 1):
  • [25] Pediatric cardiac catheterization
    Rocchini, AP
    CURRENT OPINION IN CARDIOLOGY, 2002, 17 (03) : 283 - 288
  • [26] Near infrared spectroscopy monitoring during seizures
    Sokol, DK
    Markand, ON
    Daly, EC
    Luerssen, T
    Malkoff, MD
    NEUROLOGY, 1998, 50 (04) : A287 - A287
  • [27] Monitoring blood loss with near infrared spectroscopy
    Torella, F
    Cowley, R
    Thorniley, MS
    McCollum, CN
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR AND INTEGRATIVE PHYSIOLOGY, 2002, 132 (01): : 199 - 203
  • [28] Monitoring of wood decay by near infrared spectroscopy
    Sandak, Anna
    Ferrari, Silvia
    Sandak, Jakub
    Allegretti, Ottaviano
    Terziev, Nasko
    Riggio, Mariapaola
    STRUCTURAL HEALTH ASSESSMENT OF TIMBER STRUCTURES, 2013, 778 : 802 - 809
  • [29] NEAR-INFRARED SPECTROSCOPY IN FETAL MONITORING
    OBRIEN, PMS
    DOYLE, PM
    ROLFE, P
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 49 (07): : 483 - &
  • [30] Evaluation of calibration methods for size estimation in the pediatric cardiac catheterization laboratory
    Szmuilowicz, E
    Sklansky, MS
    Kiciman, N
    Hilton, S
    Rothman, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (03): : 313 - 318