An Accurate Parametric Electrical Model for Slow-Wave CPW

被引:0
|
作者
Bautista, Alfredo [1 ]
Franc, Anne-Laure [2 ,3 ]
Ferrari, Philippe [1 ]
机构
[1] Univ Grenoble Alpes, IMEP LAHC, Campus Minatec,3 Parvis Louis Neel, F-38016 Grenoble, France
[2] Univ Toulouse, INPT, UPS, LAPLACE Lab Plasma & Convers Energie,ENSEEIHT, F-31071 Toulouse 7, France
[3] CNRS, LAPLACE, F-31071 Toulouse, France
关键词
Electromagnetic modeling; mm-wave integrated circuits; slow-wave coplanar waveguide; LINE;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
In this paper, a parametric predictive electrical model of the slow-wave coplanar waveguide structure (S-CPW) is presented. The model was developed under the assumption of Quasi-TEM propagation mode. Within this context, analytical formulas, parameterized by S-CPW geometric dimensions, were implied for each electric parameter in the model. The model was validated with 3D electromagnetic simulations and measurement results on the BiCMOS 130 nm technology. An excellent agreement was achieved over a wide frequency band, from DC up to 110 GHz, with a maximum error of 10 %. Consequently, the model provides a fast and powerful tool for designing and optimizing circuits based on S-CPWs.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Compact Fully Uniplanar Bandstop Filter Based on Slow-Wave Multimodal CPW Resonators
    Contreras, Adrian
    Ribo, Miquel
    Pradell, Lluis
    Raynal, Victor
    Moreno, Ignacio
    Combes, Maxence
    Ten, Milena
    IEEE MICROWAVE AND WIRELESS COMPONENTS LETTERS, 2018, 28 (09) : 780 - 782
  • [22] MATHEMATICAL-MODEL OF SLOW-WAVE ELECTRICAL-ACTIVITY OF HUMAN SMALL INTESTINE
    ROBERTSONDUNN, B
    LINKENS, DA
    MEDICAL & BIOLOGICAL ENGINEERING, 1974, 12 (06): : 750 - 758
  • [23] Analysis of Slow-Wave Activity and Slow-Wave Oscillations Prior to Somnambulism
    Jaar, Olivier
    Pilon, Mathieu
    Carrier, Julie
    Montplaisir, Jacques
    Zadra, Antonio
    SLEEP, 2010, 33 (11) : 1511 - 1516
  • [24] ELECTRICAL STATUS EPILEPTICUS DURING SLOW-WAVE SLEEP - A REVIEW
    JAYAKAR, PB
    SESHIA, SS
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1991, 8 (03) : 299 - 311
  • [25] LOWER HYBRID RESONANCE AND PARAMETRIC DECAY EXCITED BY A SLOW-WAVE DEVICE
    BRUSATI, M
    CIMA, G
    FONTANESI, M
    SINDONI, E
    LETTERE AL NUOVO CIMENTO, 1974, 10 (02): : 67 - 72
  • [26] ALTERATION OF SLOW-WAVE FREQUENCY IN DOG STOMACH BY ELECTRICAL STIMULI
    BARDAKJIAN, BL
    MUI, HY
    ELSHARKAWY, TY
    DIAMANT, NE
    GASTROENTEROLOGY, 1983, 84 (05) : 1097 - 1097
  • [27] CHARACTERISTICS OF THE ELECTRICAL SLOW-WAVE FREQUENCY GRADIENT IN THE CAT STOMACH
    XUE, SW
    TREMBLAY, L
    COLLMAN, P
    DIAMANT, NE
    GASTROENTEROLOGY, 1993, 104 (04) : A604 - A604
  • [28] SLOW-WAVE SLEEP
    ADAM, K
    BULLETIN OF THE BRITISH PSYCHOLOGICAL SOCIETY, 1976, 29 (AUG): : 281 - 281
  • [29] Slow-wave mode
    Johnson, H
    EDN, 2001, 46 (25) : 28 - +
  • [30] SLOW-WAVE SLEEP
    HORNE, JA
    BULLETIN OF THE BRITISH PSYCHOLOGICAL SOCIETY, 1976, 29 (NOV): : 374 - 374