Diazonium-based impedimetric aptasensor for the rapid label-free detection of Salmonella typhimurium in food sample

被引:115
|
作者
Bagheryan, Zahra [1 ,2 ]
Raoof, Jahan-Bakhsh [2 ]
Golabi, Mohsen [1 ]
Turner, Anthony P. F. [1 ]
Beni, Valerio [1 ,3 ]
机构
[1] Linkoping Univ, Dept Phys Chem & Biol IFM, Biosensors & Bioelect Ctr, S-58183 Linkoping, Sweden
[2] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Eletroanalyt Chem Res Lab, Babol Sar, Iran
[3] Acreo Swedish ICT AB, Box 787, SE-60117 Norrkoping, Sweden
来源
关键词
Diazonium grafting; Aptamer; S; typhimurium; Label-free detection; Electrochemical impedance spectroscopy; Food analysis; UNITED-STATES; ANTIBODY IMMOBILIZATION; TETRATHIONATE BROTH; PATHOGEN DETECTION; ELECTRON-TRANSFER; CARBON SURFACE; DNA APTAMERS; GOLD; LAYERS; SENSOR;
D O I
10.1016/j.bios.2016.02.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fast and accurate detection of microorganisms is of key importance in clinical analysis and in food and water quality monitoring. Salmonella typhimurium is responsible for about a third of all cases of food borne diseases and consequently, its fast detection is of great importance for ensuring the safety of foodstuffs. We report the development of a label-free impedimetric aptamer-based biosensor for S. typhimurium detection. The aptamer biosensor was fabricated by grafting a diazonium-supporting layer onto screen printed carbon electrodes (SPEs), via electrochemical or chemical approaches, followed by chemical immobilisation of aminated-aptamer. FTIR-ATR, contact angle and electrochemical measurements were used to monitor the fabrication process. Results showed that electrochemical immobilisation of the diazonium-grafting layer allowed the formation of a denser aptamer layer, which resulted in higher sensitivity. The developed aptamer-biosensor responded linearly, on a logarithm scale, over the concentration range 1 x 10(1) to 1 x 10(8) CFU mL(-1), with a limit of quantification (LOQ) of 1 x 10(1) CFU mL(-1) and a limit of detection (LOD) of 6 CFU mL(-1). Selectivity studies showed that the aptamer biosensor could discriminate S. typhimurium from 6 other model bacteria strains. Finally, recovery studies demonstrated its suitability for the detection of S. typhimurium in spiked (1 x 10(2), 1 x 10(4) and 1 x 10(6) CFU mL(-1)) apple juice samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:566 / 573
页数:8
相关论文
共 50 条
  • [41] A Label-Free Electrochemical Aptasensor Based on a Truncated Aptamer for the Detection of Progesterone
    Yang, Jie
    Hou, Yucui
    Ren, Yi
    Tang, Chunhua
    Li, HuanHuan
    Huang, Jing
    Jiang, Hanbing
    Cai, Tongji
    Zhao, Jia
    Yu, Peng
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2022, 18 (11) : 2498 - 2507
  • [42] Development of an Impedimetric Aptasensor for Label Free Detection of Patulin in Apple Juice
    Khan, Reem
    Ben Aissa, Sondes
    Sherazi, Tauqir A.
    Catanante, Gaelle
    Hayat, Akhtar
    Marty, Jean Louis
    MOLECULES, 2019, 24 (06)
  • [43] Development of a label-free impedimetric aptasensor based on Zr-MOF and titaniom carbide nanosheets for detection of L-tryptophan
    Mohammadi, Farzaneh
    Roushani, Mahmoud
    Valipour, Akram
    BIOELECTROCHEMISTRY, 2024, 155
  • [44] Label-free impedimetric biosensors for the control of food safety - a review
    Malvano, Francesca
    Pilloton, Roberto
    Albanese, Donatella
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (04) : 468 - 491
  • [45] A Label-Free Aptasensor for Ochratoxin a Detection Based on the Structure Switch of Aptamer
    Liu, Feng
    Ding, Ailing
    Zheng, Jiushang
    Chen, Jiucun
    Wang, Bin
    SENSORS, 2018, 18 (06)
  • [46] Label-free fluorescence aptasensor based on AuNPs and CQDs for the detection of ATP
    Ren, Linjiao
    Xu, Peng
    Zhang, Pei
    Qin, Zirui
    Zhang, Yintang
    Jiang, Liying
    AIP ADVANCES, 2021, 11 (01)
  • [47] Label-Free Aptasensor for Detection of Fipronil Based on Black Phosphorus Nanosheets
    Huang, Hao
    Zhang, Chuanxiang
    Zhou, Jie
    Wei, Dan
    Ma, Tingting
    Guo, Wenfei
    Liu, Xueying
    Li, Song
    Deng, Yan
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [48] A facile label-free G-quadruplex based fluorescent aptasensor method for rapid detection of ATP
    Liu, Haisheng
    Ma, Changbei
    Ning, Feng
    Chen, Hanchun
    He, Hailun
    Wang, Kemin
    Wang, Jun
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 175 : 164 - 167
  • [49] Label-free SERS detection of Salmonella Typhimurium on DNA aptamer modified AgNR substrates
    Chen, Jing
    Park, Bosoon
    Huang, Yao-wen
    Zhao, Yiping
    Kwon, Yongkuk
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2017, 11 (04) : 1773 - 1779
  • [50] Label-free SERS detection of Salmonella Typhimurium on DNA aptamer modified AgNR substrates
    Jing Chen
    Bosoon Park
    Yao-wen Huang
    Yiping Zhao
    Yongkuk Kwon