Diazonium-based impedimetric aptasensor for the rapid label-free detection of Salmonella typhimurium in food sample

被引:115
|
作者
Bagheryan, Zahra [1 ,2 ]
Raoof, Jahan-Bakhsh [2 ]
Golabi, Mohsen [1 ]
Turner, Anthony P. F. [1 ]
Beni, Valerio [1 ,3 ]
机构
[1] Linkoping Univ, Dept Phys Chem & Biol IFM, Biosensors & Bioelect Ctr, S-58183 Linkoping, Sweden
[2] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Eletroanalyt Chem Res Lab, Babol Sar, Iran
[3] Acreo Swedish ICT AB, Box 787, SE-60117 Norrkoping, Sweden
来源
关键词
Diazonium grafting; Aptamer; S; typhimurium; Label-free detection; Electrochemical impedance spectroscopy; Food analysis; UNITED-STATES; ANTIBODY IMMOBILIZATION; TETRATHIONATE BROTH; PATHOGEN DETECTION; ELECTRON-TRANSFER; CARBON SURFACE; DNA APTAMERS; GOLD; LAYERS; SENSOR;
D O I
10.1016/j.bios.2016.02.024
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fast and accurate detection of microorganisms is of key importance in clinical analysis and in food and water quality monitoring. Salmonella typhimurium is responsible for about a third of all cases of food borne diseases and consequently, its fast detection is of great importance for ensuring the safety of foodstuffs. We report the development of a label-free impedimetric aptamer-based biosensor for S. typhimurium detection. The aptamer biosensor was fabricated by grafting a diazonium-supporting layer onto screen printed carbon electrodes (SPEs), via electrochemical or chemical approaches, followed by chemical immobilisation of aminated-aptamer. FTIR-ATR, contact angle and electrochemical measurements were used to monitor the fabrication process. Results showed that electrochemical immobilisation of the diazonium-grafting layer allowed the formation of a denser aptamer layer, which resulted in higher sensitivity. The developed aptamer-biosensor responded linearly, on a logarithm scale, over the concentration range 1 x 10(1) to 1 x 10(8) CFU mL(-1), with a limit of quantification (LOQ) of 1 x 10(1) CFU mL(-1) and a limit of detection (LOD) of 6 CFU mL(-1). Selectivity studies showed that the aptamer biosensor could discriminate S. typhimurium from 6 other model bacteria strains. Finally, recovery studies demonstrated its suitability for the detection of S. typhimurium in spiked (1 x 10(2), 1 x 10(4) and 1 x 10(6) CFU mL(-1)) apple juice samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:566 / 573
页数:8
相关论文
共 50 条
  • [1] A new label-free impedimetric aptasensor for gluten detection
    Malvano, Francesca
    Albanese, Donatella
    Pilloton, Roberto
    Di Matteo, Marisa
    FOOD CONTROL, 2017, 79 : 200 - 206
  • [2] Label-free electrochemical aptasensor based on cellulose nanocrystal-modified paper-based device for Salmonella Typhimurium detection in food samples
    Jampasa, Sakda
    Sangthong, Natthawut
    Ozer, Tugba
    Panphut, Wattana
    Naorungroj, Sarida
    Ngamrojanavanich, Nattaya
    Kaneta, Takashi
    Chailapakul, Orawon
    Wonsawat, Wanida
    MICROCHEMICAL JOURNAL, 2025, 211
  • [3] Development of a label-free impedimetric aptasensor for the detection of Acinetobacter baumannii bacteria
    Abedi, Rokhsareh
    Raoof, Jahan Bakhsh
    Mohseni, Mojtaba
    Hashkavayi, Ayemeh Bagheri
    ANALYTICAL BIOCHEMISTRY, 2023, 679
  • [4] A label-free impedimetric aptasensor for the detection of Bacillus anthracis spore simulant
    Mazzaracchio, Vincenzo
    Neagu, Daniela
    Porchetta, Alessandro
    Marcoccio, Eleonora
    Pomponi, Alice
    Faggioni, Giovanni
    D'Amore, Nino
    Notargiacomo, Andrea
    Pea, MarialLilia
    Moscone, Danila
    Palleschi, Giuseppe
    Lista, Florigio
    Arduini, Fabiana
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 640 - 646
  • [5] Nanocrystalline diamond impedimetric aptasensor for the label-free detection of human IgE
    Tran, Dinh T.
    Vermeeren, Veronique
    Grieten, Lars
    Wenmackers, Sylvia
    Wagner, Patrick
    Pollet, Jeroen
    Janssen, Kris P. P.
    Michiels, Luc
    Lammertyn, Jeroen
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (06): : 2987 - 2993
  • [6] Magnetic silica nanotube-assisted impedimetric immunosensor for the separation and label-free detection of Salmonella typhimurium
    Phuong Diem Nguyen
    Trong Binh Tran
    Dung Thi Xuan Nguyen
    Min, Junhong
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 197 : 314 - 320
  • [7] Label-free detection of Salmonella typhimurium with ssDNA aptamers
    Park, Bosoon
    Wang, Bin
    Lou, Zhichao
    Xu, Bingqian
    Kwon, Yongkuk
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [8] Polythionine and gold nanostar-based impedimetric aptasensor for label-free detection of α-synuclein oligomers
    Tao, Dan
    Wang, Jiao
    Song, Shizhen
    Cai, Ke
    Jiang, Mingdi
    Cheng, Jing
    Hu, Liang
    Jaffrezic-Renault, Nicole
    Guo, Zhenzhong
    Pan, Hongzhi
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2021, 51 (11) : 1523 - 1533
  • [9] Polythionine and gold nanostar-based impedimetric aptasensor for label-free detection of α-synuclein oligomers
    Dan Tao
    Jiao Wang
    Shizhen Song
    Ke Cai
    Mingdi Jiang
    Jing Cheng
    Liang Hu
    Nicole Jaffrezic-Renault
    Zhenzhong Guo
    Hongzhi Pan
    Journal of Applied Electrochemistry, 2021, 51 : 1523 - 1533
  • [10] A methodology for rapid detection of Salmonella typhimurium using label-free electrochemical impedance spectroscopy
    Nandakumar, Vivek
    La Belle, Jeffrey T.
    Reed, Justin
    Shah, Miti
    Cochran, Douglas
    Joshi, Lokesh
    Alford, T. L.
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (04): : 1039 - 1042