Dioxin levels in the emissions from municipal waste incinerators in Taiwan

被引:5
|
作者
Chang, MB [1 ]
Lee, CH [1 ]
机构
[1] Natl Cent Univ, Grad Inst Environ Engn, Chungli 320, Taiwan
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, characteristics of dioxins emission from existing modern MWIs were evaluated via simultaneous sampling of flue gas and various types of fly ashes. Preliminary results showed that PCDDs congeners distributions were quite similar in flue gas and various types of ashes of both MWIs. PCDFs/PCDDs ratio in cyclone ash was lower than that in combustor ash or fabric filter ash excluding economizer ash of MWI-A. Similarly, PCDFs/PCDDs ratio in ESP ash was lower than that in boiler ash. PCDFs concentration was about 1.5 to 4.3 times higher than PCDDs concentration in flue gas of both MWIs. The mass balance factors of MWI-A (0.9 similar to 1.02) were clearly lower than that of MWI-B (7.71 similar to 15.63), indicating that de novo synthesis occurred under the operating conditions of ESP. In other words, MWIs equipped with ESP were less efficient in controlling PCDD/Fs emissions than that equipped with fabric filters. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2483 / 2490
页数:8
相关论文
共 50 条
  • [21] Emissions of PCDD/Fs from municipal solid waste incinerators in China
    Ni, Yuwen
    Zhang, Haijun
    Fan, Su
    Zhang, Xueping
    Zhang, Qing
    Chen, Jiping
    [J]. CHEMOSPHERE, 2009, 75 (09) : 1153 - 1158
  • [22] An assessment of realistic emissions from municipal, medical, and hazardous waste incinerators
    Hasselriis, F
    [J]. ENVIRONMENTAL ENGINEERING SCIENCE, 1998, 15 (02) : 171 - 180
  • [23] REDUCTION OF ORGANOCHLORINE EMISSIONS FROM MUNICIPAL AND HAZARDOUS-WASTE INCINERATORS
    DOUGHERTY, RC
    COLLAZOLOPEZ, H
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1987, 21 (06) : 602 - 604
  • [24] EMISSIONS OF ORGANIC MICROPOLLUTANTS FROM DISCONTINUOUSLY OPERATED MUNICIPAL WASTE INCINERATORS
    BENESTAD, C
    HAGEN, I
    JEBENS, A
    OEHME, M
    RAMDAHL, T
    [J]. WASTE MANAGEMENT & RESEARCH, 1990, 8 (03) : 193 - 201
  • [25] National annual dioxin emissions estimate for hazardous waste incinerators
    Cudahy, JJ
    Rigo, HG
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1998, 48 (11): : 1107 - 1111
  • [26] A SIMPLIFIED MODEL FOR DIOXIN AND FURAN FORMATION IN MUNICIPAL-WASTE INCINERATORS
    WIESENHAHN, DF
    LI, CP
    PENNER, SS
    [J]. ENERGY, 1988, 13 (03) : 225 - 237
  • [27] Prediction of PCDD and PCDF emissions from municipal solid waste (MSW) incinerators
    Cains, PW
    Eduljee, GH
    [J]. CHEMOSPHERE, 1997, 34 (01) : 51 - 69
  • [28] PCDD/Fs levels in indoor environments and blood of workers of three municipal waste incinerators in Taiwan
    Hu, SW
    ChangChien, GP
    Chan, CC
    [J]. CHEMOSPHERE, 2004, 55 (04) : 611 - 620
  • [29] Estimation of dioxin exposure concentrations and dioxin intakes of workers at continuously burning municipal waste incinerators
    Kumagai, S
    Koda, S
    Miyakita, T
    Yamaguchi, H
    Katagi, K
    Ueno, M
    [J]. JOURNAL OF OCCUPATIONAL HEALTH, 2001, 43 (02) : 61 - 69
  • [30] EMISSIONS OF METALS AND ORGANICS FROM MUNICIPAL WASTE-WATER SLUDGE INCINERATORS
    PARRISH, CR
    PALAZZOLO, MA
    VANCIL, MA
    BOSTIAN, HE
    CRUMPLER, EP
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 1991, 69 (B1) : 20 - 28