Intrinsic dual-energy processing of myocardial perfusion images

被引:0
|
作者
Brown, JK
Tang, HR
Hattner, RS
Bocher, M
Ratzlaff, NW
Kadkade, PP
Hasegawa, BH
Botvinick, EH
机构
[1] Univ Calif San Francisco, Nucl Med Sect, Div Cardiovasc, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Phys Res Lab, S San Francisco, CA USA
[3] Univ Calif San Francisco, Joint Bioengn Grad Grp, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Cardiovasc Res Inst, San Francisco, CA 94143 USA
关键词
attenuation correction; myocardial perfusion; SPECT; (TI)-T-201;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed a software-based method for processing dual-energy (TI)-T-201 SPECT emission projection data with the goal of calculating a spatially dependent index of the local impact of gamma-ray attenuation. We refer to this method as intrinsic dual-energy processing (IDEP). Methods: IDEP exploits the differential attenuation of lower energy emissions (69-83 keV) and higher energy emissions (167 keV) resulting from the decay of (TI)-T-201 to characterize the relative degree of low-energy gamma-ray attenuation throughout the myocardium. In particular, IDEP can be used to estimate the relative probability that a low-energy gamma-ray emitted from a particular region of the myocardium is detected during the acquisition of SPECT projection data. Studies on phantoms and healthy human Volunteers were performed to determine whether the IDEP method yielded detection probability images with systematic structure visible above the noise of these images and whether the systematic structure in the detection probability images could be rationalized physically. In patient studies, the relative regional detection probabilities were applied qualitatively to determine the likely effects of attenuation on the distribution of mapped photon emissions. Results: Measurements of the detection probability in uniform phantoms showed excellent agreement with those obtained from computer simulations for both 180 degrees and 360 degrees acquisitions. Additional simulations with digital phantoms showed good correlation between IDEP-estimated detection probabilities and calculated detection probabilities. In patient studies, the IDEP-derived detection probability maps showed qualitative agreement with known nonuniform attenuation characteristics of the human thorax. When IDEP data were integrated with the findings on the emission scan, the correlation with coronary anatomy (known in 6 patients and hypothesized on the basis of clinical and electrocardiographic parameters in 5 patients) was improved compared with evaluating the mapped emission image alone. Conclusion: The IDEP method has the potential to characterize the attenuation properties of an object without use of a separate transmission scan. Coupled with the emission data, it may aid coronary diagnosis.
引用
收藏
页码:1287 / 1297
页数:11
相关论文
共 50 条
  • [21] The evaluation of myocardial infarction with dual-energy myocardial perfusion using second-generation dual-source CT: an experimental study in a pig model
    Zhao Ruiping
    Li Hongyu
    Lu Yaojun
    Sun Kai
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (16) : C124 - C124
  • [22] Dual-Energy CT: Techniques in Acquisition and Image Processing
    Pelc, N.
    MEDICAL PHYSICS, 2016, 43 (06) : 3746 - 3746
  • [23] Dual-Energy CT Post-processing Applications
    Martin S.S.
    Vogl T.J.
    Wichmann J.L.
    Current Radiology Reports, 3 (9)
  • [24] Comparison of Myocardial Perfusion Evaluation with Single Versus Dual-Energy CT and Effect of Beam-Hardening Artifacts
    Carrascosa, Patricia M.
    Cury, Ricardo C.
    Deviggiano, Alejandro
    Capunay, Carlos
    Campisi, Roxana
    Lopez de Munain, Marina
    Vallejos, Javier
    Tajer, Carlos
    Rodriguez-Granillo, Gaston A.
    ACADEMIC RADIOLOGY, 2015, 22 (05) : 591 - 599
  • [25] Characterizing the local impact of attenuation in myocardial SPECT using intrinsic dual energy processing (IDEP).
    Brown, JK
    Tang, HR
    Botvinick, EH
    Hattner, RS
    Bocher, M
    Ratzlaff, NW
    Kadkade, PP
    Hasegawa, BH
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 63 - 63
  • [26] Adaptive noise correction of dual-energy computed tomography images
    Rafael Simon Maia
    Christian Jacob
    Amy K. Hara
    Alvin C. Silva
    William Pavlicek
    J. Ross Mitchell
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 667 - 678
  • [27] Diagnostic value of quantitative parameters for myocardial perfusion assessment in patients with suspected coronary artery disease by single- and dual-energy computed tomography myocardial perfusion imaging
    Ruiz-Munoz, Aroa
    Valente, Filipa
    Dux-Santoy, Lydia
    Guala, Andrea
    Teixido-Tura, Gisela
    Galian-Gay, Laura
    Gutierrez, Laura
    Fernandez-Galera, Ruben
    Casas, Guillem
    Gonzalez-Alujas, Teresa
    Ferreira-Gonzalez, Ignacio
    Evangelista, Arturo
    Rodriguez-Palomares, Jose
    IJC HEART & VASCULATURE, 2021, 32
  • [28] Correlation between Dual-Energy and Perfusion CT in Patients with Hepatocellular Carcinoma
    Gordic, Sonja
    Puippe, Gilbert D.
    Krauss, Bernhard
    Klotz, Ernst
    Desbiolles, Lotus
    Lesurtel, Mickael
    Mullhaupt, Beat
    Pfammatter, Thomas
    Alkadhi, Hatem
    RADIOLOGY, 2016, 280 (01) : 78 - 87
  • [29] Adaptive noise correction of dual-energy computed tomography images
    Maia, Rafael Simon
    Jacob, Christian
    Hara, Amy K.
    Silva, Alvin C.
    Pavlicek, William
    Mitchell, J. Ross
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (04) : 667 - 678
  • [30] Myocardial Viability by Dual-Energy Delayed Enhancement Computed Tomography
    Hamilton-Craig, Christian
    Seltmann, Martin
    Ropers, Dieter
    Achenbach, Stephan
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (02) : 207 - 208