Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

被引:10
|
作者
Troussel, Ph. [1 ]
Dennetiere, D. [2 ]
Maroni, R. [1 ]
Hoghoj, P. [3 ]
Hedacq, S. [3 ]
Cibik, L. [4 ]
Krumrey, M. [4 ]
机构
[1] CEA, DAM, DIF, F-91297 Arpajon, France
[2] Synchrotron Soleil, F-91190 St Aubin, France
[3] Xenocs SA, F-38360 Sassenage, France
[4] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
Non-periodic multilayer mirror; X-ray; Laser plasma; Synchrotron radiation; X-ray imaging; LMJ; BESSY-II; SUPERMIRRORS; BEAMLINE; MIRRORS; DESIGN;
D O I
10.1016/j.nima.2014.07.048
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The "Commissariat a Fenergie atomique et aux energies alternatives" (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser Megajoule (LMJ) Facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45 degrees) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 key to 22 key, A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion clue to the field of the microscope. We present a study of such a so-called Gael mirror which was optimized for photon energy of 10.35 key, The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 4
页数:4
相关论文
共 50 条
  • [1] Investigation of multilayer X-ray optics for the 6 keV to 20 keV energy range
    Oberta, P.
    Platonov, Y.
    Flechsig, U.
    JOURNAL OF SYNCHROTRON RADIATION, 2012, 19 : 675 - 681
  • [2] MULTILAYER OPTICS FOR MONOCHROMATIC HIGH-RESOLUTION X-RAY IMAGING MICROSCOPES
    Troussel, Ph.
    Do, A.
    Gontier, D.
    Dennetiere, D.
    Hoghoj, P.
    Hedacq, S.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS X, 2015, 9588
  • [3] Quantification of the monochromatic photon flux of refractive x-ray monochromators in the energy range from 10 to 30 keV
    Ebel, H
    X-RAY SPECTROMETRY, 2002, 31 (05) : 368 - 372
  • [4] Applications of non-periodic multilayer optics for high-resolution x-ray microscopes below 30 keV
    Troussel, Ph.
    Dennetiere, D.
    Rousseau, A.
    Darbon, S.
    Hoghoj, P.
    Hedacq, S.
    Krumrey, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [5] High-resolution 22-52 keV backlighter sources and application to X-ray radiography
    Vaughan, K.
    Moore, A. S.
    Smalyuk, V.
    Wallace, K.
    Gate, D.
    Glendinning, S. G.
    McAlpin, S.
    Park, H. S.
    Sorce, C.
    Stevenson, R. M.
    HIGH ENERGY DENSITY PHYSICS, 2013, 9 (03) : 635 - 641
  • [6] High resolution spectrometer for extended x-ray absorption fine structure measurements in the 6 keV to 15 keV energy range
    Seely, J. F.
    Hudson, L. T.
    Henins, Albert
    Feldman, U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [7] Design and fabrication of supermirrors for (2-10 keV) high resolution X-ray plasmas diagnostic imaging
    Maury, H.
    Bridou, F.
    Troussel, Ph.
    Meltchakov, E.
    Delmotte, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 242 - 246
  • [8] Multilayer Laue lenses as high-resolution x-ray optics
    Maser, J
    Stephenson, GB
    Vogt, S
    Yun, W
    Macrander, A
    Kang, HC
    Liu, C
    Conley, R
    DESIGN AND MICROFABRICATION OF NOVEL X-RAY OPTICS II, 2004, 5539 : 185 - 194
  • [9] High x-ray resolving power utilizing asymmetric diffraction from a quartz transmission crystal measured in the 6 keV to 22 keV energy range
    Seely, John F.
    Galtier, Eric
    Hudson, Lawrence T.
    Henins, Albert
    Feldman, Uri
    APPLIED OPTICS, 2019, 58 (19) : 5225 - 5232
  • [10] X-RAY OPTICS - A TECHNIQUE FOR HIGH-RESOLUTION IMAGING
    CASH, W
    APPLIED OPTICS, 1987, 26 (14): : 2915 - 2920