Haemodynamic responses following orotracheal intubation in patients with hypertension-Macintosh direct laryngoscope versus Glidescope®videolaryngoscope

被引:10
|
作者
Meshram, Tanvi M. [1 ]
Ramachandran, Rashmi [1 ]
Trikha, Anjan [1 ]
Rewari, Vimi [1 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Anaesthesiol Pain Med & Crit Care, New Delhi, India
关键词
Glidescope; haemodynamic response; intubation; Macintosh laryngoscope; CERVICAL-SPINE; GLIDESCOPE(R); VIDEOLARYNGOSCOPE;
D O I
10.4103/ija.IJA_417_20
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Glidescope (R) videolaryngoscope (GVL) is a video intubation system with 60 degrees angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope (R) videolaryngoscope (GVL) in hypertensive patients. Methods: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. Results: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. Conclusion: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [21] Cardiovascular responses following laryngoscope assisted, fibreoptic orotracheal intubation
    Tong, JL
    Ashworth, DR
    Smith, JE
    ANAESTHESIA, 2005, 60 (08) : 754 - 758
  • [22] Comparison of McGrath Videolaryngoscope versus Macintosh Laryngoscope in Tracheal Intubation: An Updated Systematic Review
    Sansone, Pasquale
    Giaccari, Luca Gregorio
    Bonomo, Antonio
    Gargano, Francesca
    Aurilio, Caterina
    Coppolino, Francesco
    Passavanti, Maria Beatrice
    Pota, Vincenzo
    Pace, Maria Caterina
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (19)
  • [23] Comparison of the GlideScope® with the Macintosh laryngoscope for tracheal intubation in patients with simulated difficult airway
    Lim, Y
    Yeo, SW
    ANAESTHESIA AND INTENSIVE CARE, 2005, 33 (02) : 243 - 247
  • [24] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Huang, Ping
    Zhou, Renlong
    Lu, Zhixing
    Hang, Yannan
    Wang, Shanjuan
    Huang, Zhenling
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [25] GlideScope® versus C-MAC®(D) videolaryngoscope versus Macintosh laryngoscope for double lumen endotracheal intubation in patients with predicted normal airways: a randomized, controlled, prospective trial
    Ping Huang
    Renlong Zhou
    Zhixing Lu
    Yannan Hang
    Shanjuan Wang
    Zhenling Huang
    BMC Anesthesiology, 20
  • [26] Comparison of the tracheal intubation using Macintosh laryngoscope and GlideScope® videolaryngoscope by advanced cardiac life support providers in a manikin study
    Yuan, Y. J.
    Xue, F. S.
    Wang, Q.
    Liu, J. H.
    Xiong, J.
    Liao, X.
    MINERVA ANESTESIOLOGICA, 2011, 77 (05) : 558 - 559
  • [27] Comparison of haemodynamic responses to tracheal intubation using the Airway Scope® and Macintosh laryngoscope in normotensive and hypertensive patients
    Koyama, Y.
    Nishihama, M.
    Inagawa, G.
    Kamiya, Y.
    Miki, T.
    Kurihara, R.
    Goto, T.
    ANAESTHESIA, 2011, 66 (10) : 895 - 900
  • [28] Cardiovascular responses following laryngoscope-assisted fibreoptic orotracheal intubation
    Stacey, MR
    Rassam, S
    Sivasankar, R
    Hall, JE
    Latto, IP
    ANAESTHESIA, 2006, 61 (02) : 196 - 197
  • [29] A COMPARISON OF MACINTOSH, MCCOY AND VIDEOLARYNGOSCOPE ('GLIDESCOPE') FOR INTUBATION IN OBESE PATIENTS: A PROSPECTIVE, COMPARATIVE, RANDOMISED STUDY
    Bhalla, D. P.
    Nandakumar, K. P.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 677 - 677
  • [30] Effect of fiberoptic bronchoscope compared with direct laryngoscope on hemodynamic responses to orotracheal intubation
    ZHANG Guo-hua XUE Fu-shan LI Ping SUN Hai-yan LIU Kun-peng XU Ya-chao LIU Yi SUN Hai-tao Department of Anesthesiology
    中华医学杂志(英文版), 2007, (04) : 336 - 338