Haemodynamic responses following orotracheal intubation in patients with hypertension-Macintosh direct laryngoscope versus Glidescope®videolaryngoscope

被引:10
|
作者
Meshram, Tanvi M. [1 ]
Ramachandran, Rashmi [1 ]
Trikha, Anjan [1 ]
Rewari, Vimi [1 ]
机构
[1] All India Inst Med Sci AIIMS, Dept Anaesthesiol Pain Med & Crit Care, New Delhi, India
关键词
Glidescope; haemodynamic response; intubation; Macintosh laryngoscope; CERVICAL-SPINE; GLIDESCOPE(R); VIDEOLARYNGOSCOPE;
D O I
10.4103/ija.IJA_417_20
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Glidescope (R) videolaryngoscope (GVL) is a video intubation system with 60 degrees angle blade that provides excellent laryngeal view, does not require alignment of oral, pharyngeal, and laryngeal axes for visualisation of glottis, thus causing less stimulation of orolaryngopharynx. The aim of this study was to compare haemodynamic responses (blood pressure and heart rate) and airway morbidity using the Macintosh direct laryngoscope (MDL) and the Glidescope (R) videolaryngoscope (GVL) in hypertensive patients. Methods: Fifty patients with hypertension controlled on antihypertensive medications scheduled for elective surgery under general anaesthesia were randomly assigned to group GVL (n = 25) or group MDL (n = 25). Heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP) were recorded at baseline, after induction, pre-intubation, at intubation, 1, 2, 3, 4, and 5 min after intubation. Time to intubation, number of attempts, complications during intubation, and postoperative airway complications (sore throat, hoarseness, dysphagia, and cough) were also recorded. Results: There was a statistically significant increase in SBP, DBP, and MBP at intubation [(P = 0.003, 0.013, 0.03), 1 min (P = 0.001, 0.012, 0.02), 2 min (P = 0.04, 0.02, 0.04), and 3 min (P = 0.02, 0.01)] in the MDL group as compared to GVL group. The time to intubate was significantly greater in the GVL group as compared to MDL group (P = 0.0006). There was no significant difference in the incidence of intraoperative and postoperative airway complications. Conclusion: In the hands of an experienced anaesthesiologist, the use of GVL in controlled hypertensive patients is associated with less haemodynamic response as compared to Macintosh Laryngoscope without any increase in airway complications.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 50 条
  • [1] Comparison of Hemodynamic Responses and Upper Airway Morbidity Following Orotracheal Intubation in Hypertensive Patients - Macintosh Direct Laryngoscope Versus Glidescope Videolaryngoscope
    Rewari, Vimi
    Meshram, Tanvi
    Ramachandran, Rashmi
    Trikha, Anjan
    ANESTHESIA AND ANALGESIA, 2017, 124 : 114 - 114
  • [2] Circulatory responses to nasotracheal intubation:: comparison of GlideScope® videolaryngoscope and Macintosh direct laryngoscope
    Xue Fu-Shan
    Li Xuan-Ying
    Liu Qian-Jin
    Liu He-Ping
    Yang Quan-Yong
    Xu Ya-Chao
    Liao Xu
    Liu Yi
    CHINESE MEDICAL JOURNAL, 2008, 121 (14) : 1290 - 1296
  • [3] Comparison of hemodynamic responses to orotracheat intubation with the GlideScope® videolaryngoscope and the Macintosh direct laryngoscope
    Xue, Fu S.
    Zhang, Guo H.
    Li, Xuan Y.
    Sun, Hai T.
    Li, Ping
    Li, Cheng W.
    Liu, Kun P.
    JOURNAL OF CLINICAL ANESTHESIA, 2007, 19 (04) : 245 - 250
  • [4] Comparison of haemodynamic responses to orotracheal intubation with GlideScope® videolaryngoscope and fibreoptic bronchoscope
    Xue, FS
    Zhang, GH
    Li, XY
    Sun, HT
    Li, P
    Sun, HY
    Xu, YC
    Liu, Y
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2006, 23 (06) : 522 - 526
  • [6] GlideScope videolaryngoscope vs. Macintosh direct laryngoscope for intubation of morbidly obese patients: a randomized trial
    Andersen, L. H.
    Rovsing, L.
    Olsen, K. S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (09) : 1090 - 1097
  • [7] Comparison of the GlideScope® videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation
    Hsu, H. -T.
    Chou, S. -H.
    Wu, P. -J.
    Tseng, K. -Y.
    Kuo, Y. -W.
    Chou, C. -Y.
    Cheng, K. -I.
    ANAESTHESIA, 2012, 67 (04) : 411 - 415
  • [8] Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial
    Pournajafian, Ali Reza
    Ghodraty, Mohammad Reza
    Faiz, Seyed Hamid Reza
    Rahimzadeh, Poupak
    Goodarzynejad, Hamidreza
    Dogmehchi, Enseyeh
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2014, 16 (04)
  • [9] COMPARATIVE PERFORMANCE OF GLIDESCOPE VIDEOLARYNGOSCOPE WITH DIRECT LARYNGOSCOPE FOR EMERGENCY INTUBATION
    Cheng, Yi
    Xue, Fu-Shan
    Li, Rui-Ping
    Liao, Xu
    JOURNAL OF EMERGENCY MEDICINE, 2016, 51 (02): : 187 - 188
  • [10] Hemodynamic Changes during Orotracheal Intubation with the Glidescope and Direct Laryngoscope
    Mahjoubifar, M.
    Boroojeny, Sh Borjian
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2010, 12 (04) : 406 - 408