A Conformal Driving Class IV Flextensional Transducer

被引:17
|
作者
Zhou, Tianfang [1 ,2 ,3 ]
Lan, Yu [1 ,2 ,3 ]
Zhang, Qicheng [1 ]
Yuan, Jingwen [1 ]
Li, Shichang [1 ]
Lu, Wei [1 ,2 ,3 ]
机构
[1] Harbin Engn Univ, Coll Underwater Acoust Engn, Harbin 150001, Heilongjiang, Peoples R China
[2] Harbin Engn Univ, Acoust Sci & Technol Lab, Harbin 150001, Heilongjiang, Peoples R China
[3] Harbin Engn Univ, Minist Ind & Informat Technol, Key Lab Marine Informat Acquisit & Secur, Harbin 150001, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
conformal driving class IV flextensional transducer; low frequency; high power; small size; PROJECTORS;
D O I
10.3390/s18072102
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Class IV Flextensional Transducers (FTs) are the most popular among various FTs used as low-frequency and high power underwater acoustic sources. However, an undeniable fact exists in Class IV FTs is that the resonance frequency of breathing mode regulator used is fairly raised by its longitudinal driver stacks. In this research, a conformal driving Class IV FT in which the driver stacks are kept conformal with its oval shell was proposed aiming at the limitations of conventional driving Class IV FTs described above. The device exhibits competitive Transmitting Voltage Responses (TVRs) but much lower operation frequencies with respect to conventional driving Class IV FTs, through the designs of conformal and segmentally controlled driver stacks. Geometric parameters analysis was carried out extensively by Finite Element (FE) simulations for the design optimizations and then a conformal driving Class IV FT resonating at 510 Hz (45% approximately lower than that of conventional driving Class IV FT with the same shell geometry) was finalized. Subsequently the conformal driving Class IV was fabricated and tested in the anechoic tank experimentally. Good agreements of both FE predictions and experimental results demonstrate its low-frequency and small-size acoustic performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] The Study of Broadband Flextensional Transducer
    Chen, Si
    Lan, Yu
    INTERNATIONAL CONFERENCE ON GRAPHIC AND IMAGE PROCESSING (ICGIP 2012), 2013, 8768
  • [22] FLEXTENSIONAL UNDERWATER ACOUSTICS TRANSDUCER
    ROYSTER, LH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1969, 45 (03): : 671 - &
  • [23] Frequency fine-tuning in Class IV flextensional transducers
    Moosad, K. P. B.
    Krishnakumar, P.
    Chandrashekar, G.
    Vishnubhatla, R. M. R.
    APPLIED ACOUSTICS, 2007, 68 (10) : 1280 - 1285
  • [24] Ultrasonic biopsy needle based on the class IV flextensional configuration
    Mathieson, Andrew
    Feeney, Andrew
    Tweedie, Andrew
    Lucas, Margaret
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [25] Effect of Concave Stave on Class I Barrel-Stave Flextensional Transducer
    Teng, Duo
    Liu, Xiaoyong
    Gao, Feng
    MICROMACHINES, 2021, 12 (10)
  • [26] HISTORY OF THE FLEXTENSIONAL ELECTROACOUSTIC TRANSDUCER
    ROLT, KD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (03): : 1340 - 1349
  • [27] DEVELOPMENT OF A MATHEMATICAL MODEL FOR CLASS-V FLEXTENSIONAL UNDERWATER ACOUSTIC TRANSDUCER
    NELSON, RA
    ROYSTER, LH
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1971, 49 (05): : 1609 - &
  • [28] PRESENT STATUS IN FLEXTENSIONAL TRANSDUCER TECHNOLOGY
    BRIGHAM, G
    GLASS, B
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (04): : 1046 - 1052
  • [29] Present status in flextensional transducer technology
    Brigham, G.
    Glass, B.
    Journal of the Acoustical Society of America, 1980, 68 (04): : 1046 - 1052
  • [30] Design, Modeling and Fabrication of a Novel Class V Flextensional Transducer: The Sea-Shell
    Kaya, Mustafa Yunus
    Alkoy, Sedat
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (01) : 64 - 71