COMPARISON OF DIFFERENT REFRIGERANTS FOR A TWO-STAGE TRANSPORT REFRIGERATION SYSTEM

被引:0
|
作者
Moehlenkamp, A. [1 ]
Lemke, N. [1 ]
Koehler, J. [1 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Inst Thermodynam, D-38106 Braunschweig, Germany
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The single-stage vapour compression cycle with the synthetic refrigerants R-404A and R-410A is state of the art in transport refrigeration. Both named refrigerants have a high Global Warming Potential (GWP). Current research activities focus, amongst others, on new energy efficient vapour compression cycles and the application of low GWP-refrigerants. A two-stage vapour compression cycle with an internal heat exchanger at intermediate pressure is a widely used inter-stage system at low and medium evaporating temperatures in commercial refrigeration. Such a cycle leads to a considerable increase of the system's energy efficiency compared to a single-stage unit, especially for the refrigerant R-744 in combination with low temperature applications. Due to its thermodynamic properties, the natural refrigerant R-744 with GWP(100)=1 might be an eco-friendly and competitive alternative to the commonly used synthetic high-GWP-refrigerants R-404A and R-410A. In this paper, a numerical comparison of a R-410A and a R-744 two-stage vapour compression cycle with an internal heat exchanger at intermediate pressure for transport refrigeration is presented. The object oriented modelling language Modelica and the component library TIL are used to model the refrigerant cycle. This model is validated against previously published experimental data of a R-744 two-stage test unit for commercial transport refrigeration. Thermo-physical effects such as pressure drop and heat transfer in the different components of the refrigeration cycle are considered in the model by general correlations. The applied model predicts the measured cooling capacities and the Coefficients of Performance (COP) within an uncertainty of 4 and 8%, respectively. A simulative comparison of the R-410A and the R-744 two-stage vapour compression cycle is presented and discussed for two different applications: The COP of both refrigerants is compared for a constant cooling capacity of 15kW and varying ambient temperature. The average energy consumption per year of a transport refrigeration system in Germany, Spain and the USA is estimated for both refrigerants.
引用
收藏
页码:676 / 686
页数:11
相关论文
共 50 条
  • [31] HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature
    Llopis, R.
    Torrella, E.
    Cabello, R.
    Sanchez, D.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04): : 810 - 816
  • [32] ENERGY, EXERGY AND SUSTAINABILITY ANALYSIS OF TWO-STAGE VAPOUR COMPRESSION REFRIGERATION SYSTEM
    Chopra, Kapil
    Sahni, V.
    Mishra, R. S.
    JOURNAL OF THERMAL ENGINEERING, 2015, 1 (04): : 440 - 445
  • [33] Performance Analysis of a Carbon Dioxide Transcritical Two-Stage Compression Refrigeration System
    Wei, Zhiyong
    Wang, Jinfeng
    Xie, Jing
    Xu, Hao
    Wu, Chenlong
    Ye, Guosen
    Jiang, Jilin
    Han, Xinrong
    NEW ENERGY AND FUTURE ENERGY SYSTEMS, NEFES 2023, 2023, 45 : 92 - 102
  • [34] Optimum performance analysis of a two-stage irreversible magnetization Brayton refrigeration system
    Zhang, Yue
    Lin, Bihong
    Chen, Jincan
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (20) : 4293 - 4298
  • [35] A Review on Energy and Exergy Analysis of Two-Stage Vapour Compression Refrigeration System
    Chowdhury, Shounak
    Roy, Ranendra
    Mandal, Bijan Kumar
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2019, 27 (02)
  • [36] Optimal design of two-stage ejector for subzero refrigeration system on fishing vessel
    Wang, Xinli
    Wang, Lei
    Song, Yajie
    Deng, Jie
    Zhan, Youjie
    APPLIED THERMAL ENGINEERING, 2021, 187
  • [37] THERMODYNAMICAL STUDY AND TAGUCHI OPTIMIZATION OF A TWO-STAGE VAPOR COMPRESSION REFRIGERATION SYSTEM
    Kaya, Alaattin Metin
    THERMAL SCIENCE, 2022, 26 (05): : 3951 - 3963
  • [38] Energy, exergy and economic optimization of a two-stage refrigeration system using low-GWP alternative refrigerants for high-temperature lift applications
    Roy, Ranendra
    Mandal, Bijan Kumar
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2023, 45 (08)
  • [39] Energy, exergy and economic optimization of a two-stage refrigeration system using low-GWP alternative refrigerants for high-temperature lift applications
    Ranendra Roy
    Bijan Kumar Mandal
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45
  • [40] Noise control of a two-stage screw refrigeration compressor
    He, Zhilong
    Han, Yaoxiang
    Chen, Wenqing
    Zhou, Minglong
    Xing, Ziwen
    APPLIED ACOUSTICS, 2020, 167