Wavelength Selection Method Based on Absorbance Value Optimization to Near-Infrared Spectroscopic Analysis

被引:2
|
作者
Yao, Lijun [1 ]
Shi, Xiaowen [1 ]
Pan, Tao [1 ]
Chen, Jiemei [2 ]
机构
[1] Jinan Univ, Dept Optoelect Engn, Guangdong Prov Key Lab Opt Fiber Sensing & Commun, Guangzhou, Peoples R China
[2] Jinan Univ, Dept Biol Engn, Guangzhou, Peoples R China
来源
FRONTIERS IN PHYSICS | 2021年 / 9卷
基金
中国国家自然科学基金;
关键词
near-infrared spectroscopic analysis; absorbance value optimization; multi-band optimization; total cholesterol; triglycerides; SUCCESSIVE PROJECTIONS ALGORITHM; REFLECTANCE SPECTROSCOPY; VARIABLE ELIMINATION; RAPID-DETERMINATION; COMBINATION METHOD; HUMAN SERUM; SPECTROMETRY; MODELS; COD;
D O I
10.3389/fphy.2021.663573
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Regarding absorption spectrum, high absorption corresponds to low light transmittance and relatively loud noise, whereas low absorption corresponds to low information content, which interferes with the modeling of spectral analysis. Appropriate absorbance level is necessary to improve spectral information content and reduces noise level. In this study, based on the selection of the upper and lower bounds of absorbance, the absorbance value optimization partial least squares (AVO-PLS) method was proposed for appropriate wavelength model selection. Near-infrared spectroscopic analysis of hyperlipidemia indicators, namely, total cholesterol (TC), and triglyceride (TG), was conducted to validate the predicted performance of AVO-PLS. Well-performed wavelength selection methods, namely, moving-window PLS (MW-PLS) of continuous type-and successive projections algorithm (SPA) of discrete type, were also conducted for comparison. The spectra were first corrected using Savitzky-Golay smoothing. Modeling was performed based on the multiple partitioning of calibration and prediction sets to avoid data over-fitting and achieve parameter stability. The selected absorbance ranged from 0.45 to 0.86 for TC and from 0.45 to 0.92 for TG, and the corresponding waveband combinations were 1,376-1,388 and 1,560-1840 nm for TC and 1,376-1,390 and 1,552-1,846 nm for TG. Among them, the waveband combination of TG covers TC's one, and can be used for the high-precision cooperativity analysis of the two indicators. Using the independent validation samples, the RMSEP and R-P of 0.164 mmol l(-1) and 0.990 for TC and 0.096 mmol l(-1) and 0.997 for TG were obtained by the cooperativity model. And the sensitivity and specificity for hyperlipidemia were 98.0 and 100%, respectively. These values were better than those of MW-PLS and SPA. Importantly, the proposed AVO-PLS is a novel multi-band optimization approach for improving prediction performance and applicability. This method is expected to obtain more applications.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] WAVELENGTH SELECTION IN MULTICOMPONENT NEAR-INFRARED CALIBRATION
    BROWN, PJ
    JOURNAL OF CHEMOMETRICS, 1992, 6 (03) : 151 - 161
  • [12] A Reference-Wavelength-Based Method for Improved Analysis of Near-Infrared Spectroscopy
    Chen, Yun
    Chen, Wenliang
    Shi, Zhenzhi
    Yang, Yue
    Xu, Kexin
    APPLIED SPECTROSCOPY, 2009, 63 (05) : 544 - 548
  • [13] A near infrared wavelength selection method based on the variable stability and population analysis
    Zhang Feng
    Tang Xiao-Jun
    Tong Ang-Xin
    Wang Bin
    Wang Jing-Wei
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2020, 39 (03) : 318 - 323
  • [14] Wavelength selection method for near-infrared spectroscopy based on the combination of mutual information and genetic algorithm
    Ma, Xiao-Hui
    Chen, Zheng-Guang
    Liu, Shuo
    Liu, Jin-Ming
    Tian, Xue-song
    TALANTA, 2025, 286
  • [15] Optimization of Near-Infrared Detection Model of Blueberry Sugar Content Based on Deep Belief Network and Hybrid Wavelength Selection Method
    Zhu Jin-yan
    Zhu Yu-jie
    Feng Guo-hong
    Zeng Ming-fei
    Liu Si-qi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (12) : 3775 - 3782
  • [16] Study on bionics-based swarm intelligence optimization algorithms for wavelength selection in near-infrared spectroscopy
    Long, Tingze
    Yi, Han
    Kang, Yatong
    Qiao, Ying
    Guan, Ying
    Chen, Chao
    INFRARED PHYSICS & TECHNOLOGY, 2024, 143
  • [17] Optical wavelength selection for portable hemoglobin determination by near-infrared spectroscopy method
    Tian, Han
    Li, Ming
    Wang, Yue
    Sheng, Dinggao
    Liu, Jun
    Zhang, Linna
    INFRARED PHYSICS & TECHNOLOGY, 2017, 86 : 98 - 102
  • [18] Visible and near-infrared spectroscopic determination of sugarcane chlorophyll content using a modified wavelength selection method for multivariate calibration
    Ong, Pauline
    Jian, Jinbao
    Li, Xiuhua
    Yin, Jianghua
    Ma, Guodong
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 305
  • [19] Miniaturized wavelength model optimization for visible–near-infrared spectroscopic discriminant analysis of soy sauce adulteration identification
    Xianghui Chen
    Lu Yuan
    Yongqi Huang
    Jiemei Chen
    Tao Pan
    Journal of Food Measurement and Characterization, 2023, 17 : 6157 - 6167
  • [20] WAVELENGTH SELECTION FOR NEAR-INFRARED REFLECTANCE MOISTURE METERS
    BULL, CR