Direct shear test on the interface between concrete and bedrock of dam foundation of a reservoir

被引:0
|
作者
Wang, Yong [1 ]
Li, Haifeng [1 ]
Wang, Wenxuan [2 ]
Zhang, Jianwei [2 ]
机构
[1] Pearl River Water Resources Commiss, Pearl River Water Resources Res Inst, Guangzhou 510611, Guangdong, Peoples R China
[2] North China Univ Water Conservancy & Elect Power, Coll Water Conservancy, Zhengzhou 450046, Henan, Peoples R China
关键词
D O I
10.1088/1755-1315/585/1/012174
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The weak failure surface of the dam body and the bedrock cementation surface is one of the key points of dam safety research at home and abroad. The direct shear strength of the contact surface between the dam foundation concrete and the bedrock is used as the current research on whether the dam will "slip" along the contact surface. Based on this, many different methods are used at home and abroad to determine the direct shear strength. In this paper, through the excavation of the dam foundation rock and on-site rock structure samples, 5 sets of 25-point in-situ direct shear tests on the interface between concrete and bedrock were carried out on the medium-thick-thick feldspar quartz sandstone of the main rock mass of the dam foundation to determine the dam foundation. Mechanical parameters of rock mass. Based on the results of field experiments, some reference opinions for field direct shear tests and direct shear strength selection in engineering design are put forward, which also provide a basis for subsequent numerical simulation calculations.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Earthquake response of concrete gravity dams including dam-foundation interface nonlinearities
    Arabshahi, Hamidreza
    Lotfi, Vahid
    ENGINEERING STRUCTURES, 2008, 30 (11) : 3065 - 3073
  • [32] Modal analysis of concrete arch dam-reservoir-massed foundation system in frequency domain
    Farzad, Reza
    Lotfi, Vahid
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2023, 176 (04) : 244 - 256
  • [33] Stability analysis of Llerin Rockfill Dam: An in situ direct shear test
    Oyanguren, P. Ramirez
    Nicieza, C. Gonzalez
    Fernandez, M. L. Alvarez
    Palacio, C. Gonzalez
    ENGINEERING GEOLOGY, 2008, 100 (3-4) : 120 - 130
  • [34] Frictional behaviour of the interface between concrete and rubber: Laboratory shear test and its elastoplastic model
    Zhang, Zhenyu
    Wang, Shanyong
    Feng, Jili
    ENGINEERING FRACTURE MECHANICS, 2018, 197 : 192 - 205
  • [35] Shear test on reef limestone-concrete bonding interface
    Liu Hai-feng
    Zhu Chang-qi
    Wang Ren
    Wang Xin-zhi
    Cui Xiang
    Wang Tian-min
    ROCK AND SOIL MECHANICS, 2020, 41 (05) : 1540 - 1548
  • [36] Seismic analysis of dam-foundation-reservoir coupled system using direct coupling method
    Mandal, Angshuman
    Maity, Damodar
    COUPLED SYSTEMS MECHANICS, 2019, 8 (05): : 393 - 414
  • [37] Shear transmitting capacity of interface between steel and concrete
    Zheng, Shan-Suo
    Li, Lei
    Wang, Bin
    Zeng, Lei
    Zhang, Liang
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (03): : 148 - 154
  • [38] Study of interface shear strength between sand and concrete
    Alah Karam Janipour
    Mohsen Mousivand
    Meysam Bayat
    Arabian Journal of Geosciences, 2022, 15 (2)
  • [39] Performance-based stability evaluation of earthquake induced sliding along the interface between dam and foundation for concrete gravity dams
    Shen, Huaizhi
    Zhang, Chuhan
    Jin, Feng
    Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2009, 28 (01): : 137 - 142
  • [40] Seismic response of concrete gravity dam-ice covered reservoir-foundation interaction systems
    Haciefendioglu, K.
    Bayraktar, A.
    Tuerker, T.