Evaluation of Total Corneal Thickness and Corneal Layers With Spectral-Domain Optical Coherence Tomography

被引:20
|
作者
Lopez de la Fuente, Carmen [1 ,3 ]
Sanchez-Cano, Ana [1 ,3 ]
Segura, Francisco [3 ]
Orduna Hospital, Elvira [2 ,3 ]
Pinilla, Isabel [2 ,3 ,4 ]
机构
[1] Univ Zaragoza, Dept Appl Phys, Zaragoza, Spain
[2] Univ Zaragoza, Dept Surg Gynecol & Obstet, Zaragoza, Spain
[3] Aragon Inst Hlth Res, Zaragoza, Spain
[4] Lozano Blesa Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
关键词
EPITHELIAL THICKNESS; ANTERIOR-SEGMENT; CONTACT-LENS; ULTRASOUND BIOMICROSCOPY; BOWMANS LAYER; RESOLUTION; REPRODUCIBILITY; VISUALIZATION; SCHEIMPFLUG; SLIT;
D O I
10.3928/1081597X-20151207-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate total corneal thickness and corneal layers in healthy young adults using spectral-domain optical coherence tomography and to describe its repeatability and reproducibility. METHODS: Eighty-six eyes from 86 healthy volunteers were prospectively and consecutively enrolled. Manual measurements of central corneal thickness (CCT) and central thickness of epithelium, Bowman's layer, stroma, and the Descemet-endothelium complex were performed using Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). To assess the reliability of the repeated measurements, intraclass correlation coefficients and coefficients of variation were used. RESULTS: Mean CCT, epithelium, Bowman's layer, stroma, and Descemet-endothelium values were 555.50 +/- 29.64, 54.60 +/- 4.25, 16.70 +/- 1.73, 467.51 +/- 28.91, and 16.74 +/- 1.66 mu m, respectively. The intraclass correlation coefficients ranged from 0.746 (Bowman's layer) to 0.999 (CCT and stroma) and from 0.483 (Bowman's layer) to 0.995 (CCT) and 0.998 (stroma) for intraobserver repeatability and interobserver reproducibility, respectively. The measurements showed coefficients of variation lower than 11% in all cases. CONCLUSIONS: This study establishes a normal database for corneal thickness and all its layers in healthy young adults with spectral-domain optical coherence tomography. This device exhibited a high degree of intraobserver repeatability and interobserver reproducibility for all regions except Bowman's layer.
引用
收藏
页码:27 / +
页数:7
相关论文
共 50 条
  • [11] Objective and quantitative analysis of corneal transparency with clinical spectral-domain optical coherence tomography
    Bocheux, Romain
    Riviere, Bathilde
    Pernot, Pascal
    Georgeon, Cristina
    Borderie, Vincent
    Irsch, Kristina
    Plamann, Karsten
    CLINICAL AND PRECLINICAL OPTICAL DIAGNOSTICS II, 2019, 11073
  • [12] Evaluation of corneal thickness with spectral-domain optical coherence tomography following keraring implantation for keratoconus: five year follow-up
    Eliacik, Mustafa
    Kirgiz, Ahmet
    Aygun, Beril
    CURRENT EYE RESEARCH, 2020, 45 (11) : 1359 - 1363
  • [13] Comparison of very-high-frequency ultrasound and spectral-domain optical coherence tomography corneal and epithelial thickness maps
    Urs, Raksha
    Lloyd, Harriet O.
    Reinstein, Dan Z.
    Silverman, Ronald H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 95 - 101
  • [14] Manual corneal thickness measurements of healthy equine eyes using a portable spectral-domain optical coherence tomography device
    Pirie, C. G.
    Alario, A. F.
    Barysauskas, C. M.
    Gradil, C.
    Uricchio, C. K.
    EQUINE VETERINARY JOURNAL, 2014, 46 (05) : 631 - 634
  • [15] Evaluation of Central Corneal Thickness Measurement With RTVue Spectral Domain Optical Coherence Tomography in Normal Subjects
    Rao, Harsha Laxmana
    Kumar, Addepalli Uday
    Kumar, Anjul
    Chary, Swathi
    Senthil, Sirisha
    Vaddavalli, Pravin Krishna
    Garudadri, Chandra Sekhar
    CORNEA, 2011, 30 (02) : 121 - 126
  • [16] Repeatability and Reproducibility of Corneal Epithelial Thickness Mapping With Spectral-Domain Optical Coherence Tomography in Normal and Diseased Cornea Eyes
    Sella, Ruti
    Zangwill, Linda M.
    Weinreb, Robert N.
    Afshari, Natalie A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 197 : 88 - 97
  • [17] Assessment of corneal and limbal epithelial thickness by spectral-domain optical coherence tomography in brachycephalic and non-brachycephalic dogs
    Jeong, Youngseok
    Kang, Seonmi
    Ahn, Junyeong
    Kim, Sol
    Kim, Hyelin
    Park, Jisoo
    Seo, Kangmoon
    VETERINARY OPHTHALMOLOGY, 2023, 26 : 89 - 97
  • [18] Ocular Surface Epithelial Thickness Evaluation with Spectral-Domain Optical Coherence Tomography
    Francoz, Marlene
    Karamoko, Issouf
    Baudouin, Christophe
    Labbe, Antoine
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 9116 - 9123
  • [19] Evaluation of choroidal thickness in psoriasis using spectral-domain optical coherence tomography
    K. Z. Li
    C. S. Tan
    International Ophthalmology, 2018, 38 : 417 - 418
  • [20] Evaluation of choroidal thickness in psoriasis using spectral-domain optical coherence tomography
    Li, K. Z.
    Tan, C. S.
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (02) : 417 - 418