Evaluation of Total Corneal Thickness and Corneal Layers With Spectral-Domain Optical Coherence Tomography

被引:20
|
作者
Lopez de la Fuente, Carmen [1 ,3 ]
Sanchez-Cano, Ana [1 ,3 ]
Segura, Francisco [3 ]
Orduna Hospital, Elvira [2 ,3 ]
Pinilla, Isabel [2 ,3 ,4 ]
机构
[1] Univ Zaragoza, Dept Appl Phys, Zaragoza, Spain
[2] Univ Zaragoza, Dept Surg Gynecol & Obstet, Zaragoza, Spain
[3] Aragon Inst Hlth Res, Zaragoza, Spain
[4] Lozano Blesa Univ Hosp, Dept Ophthalmol, Zaragoza, Spain
关键词
EPITHELIAL THICKNESS; ANTERIOR-SEGMENT; CONTACT-LENS; ULTRASOUND BIOMICROSCOPY; BOWMANS LAYER; RESOLUTION; REPRODUCIBILITY; VISUALIZATION; SCHEIMPFLUG; SLIT;
D O I
10.3928/1081597X-20151207-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate total corneal thickness and corneal layers in healthy young adults using spectral-domain optical coherence tomography and to describe its repeatability and reproducibility. METHODS: Eighty-six eyes from 86 healthy volunteers were prospectively and consecutively enrolled. Manual measurements of central corneal thickness (CCT) and central thickness of epithelium, Bowman's layer, stroma, and the Descemet-endothelium complex were performed using Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany). To assess the reliability of the repeated measurements, intraclass correlation coefficients and coefficients of variation were used. RESULTS: Mean CCT, epithelium, Bowman's layer, stroma, and Descemet-endothelium values were 555.50 +/- 29.64, 54.60 +/- 4.25, 16.70 +/- 1.73, 467.51 +/- 28.91, and 16.74 +/- 1.66 mu m, respectively. The intraclass correlation coefficients ranged from 0.746 (Bowman's layer) to 0.999 (CCT and stroma) and from 0.483 (Bowman's layer) to 0.995 (CCT) and 0.998 (stroma) for intraobserver repeatability and interobserver reproducibility, respectively. The measurements showed coefficients of variation lower than 11% in all cases. CONCLUSIONS: This study establishes a normal database for corneal thickness and all its layers in healthy young adults with spectral-domain optical coherence tomography. This device exhibited a high degree of intraobserver repeatability and interobserver reproducibility for all regions except Bowman's layer.
引用
收藏
页码:27 / +
页数:7
相关论文
共 50 条
  • [1] Assessment of corneal layers thickness with spectral-domain optical coherence tomography
    Segura, F.
    de la Fuente, C. Lopez
    Sachez-Cano, A.
    Orduna, E.
    Del Buey, M.
    Pinilla, I.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [2] Assessment of corneal epithelial thickness mapping by spectral-domain optical coherence tomography
    Tana-Rivero, Pedro
    Orts-Vila, Paz
    Tana-Sanz, Pedro
    Ramos-Alzamora, Maria
    Montes-Mico, Robert
    FRONTIERS IN MEDICINE, 2024, 11
  • [3] Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomography
    Maeda, Naoyuki
    Nakagawa, Tomoya
    Higashiura, Ritsuko
    Fuchihata, Mutsumi
    Koh, Shizuka
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (05) : 389 - 395
  • [4] Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomography
    Naoyuki Maeda
    Tomoya Nakagawa
    Ritsuko Higashiura
    Mutsumi Fuchihata
    Shizuka Koh
    Kohji Nishida
    Japanese Journal of Ophthalmology, 2014, 58 : 389 - 395
  • [5] Precision of High Definition Spectral-Domain Optical Coherence Tomography for Measuring Central Corneal Thickness
    Correa-Perez, Maria E.
    Lopez-Miguel, Alberto
    Miranda-Anta, Silvia
    Iglesias-Cortinas, Dario
    Alio, Jorge L.
    Maldonado, Miguel J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (04) : 1752 - 1757
  • [6] Comparison of central corneal thickness using optical low-coherence reflectometry and spectral-domain optical coherence tomography
    Lopez-Miguel, Alberto
    Encarnacion Correa-Perez, Maria
    Miranda-Anta, Silvia
    Iglesias-Cortinas, Dario
    Begona Coco-Martin, Maria
    Maldonado, Miguel J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (05): : 758 - 764
  • [7] Thickness Mapping of Retinal Layers by Spectral-Domain Optical Coherence Tomography
    Loduca, Ana L.
    Zhang, Chi
    Zelkha, Ruth
    Shahidi, Mahnaz
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (06) : 849 - 855
  • [8] Normal corneal thickness measurements in pigmented rabbits using spectral-domain anterior segment optical coherence tomography
    Wang, Xiaogang
    Wu, Qiang
    VETERINARY OPHTHALMOLOGY, 2013, 16 (02) : 130 - 134
  • [9] Evaluation of Clear Corneal Wound Dynamics With Contrast-Enhanced Spectral-Domain Optical Coherence Tomography
    Gupta, Preeya K.
    Ehlers, Justis P.
    Kim, Terry
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (03) : 222 - 228
  • [10] Objective and quantitative analysis of corneal transparency with clinical spectral-domain optical coherence tomography
    Bocheux, Romain
    Riviere, Bathilde
    Pernot, Pascal
    Georgeon, Cristina
    Borderie, Vincent
    Irsch, Kristina
    Plamann, Karsten
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)