In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry

被引:197
|
作者
Georgakopoulos, D
Mitzner, WA
Chen, CH
Byrne, BJ
Millar, HD
Hare, JM
Kass, DA
机构
[1] Johns Hopkins Med Inst, Sch Med, Dept Med, Baltimore, MD 21287 USA
[2] Johns Hopkins Med Inst, Sch Med, Div Physiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Med Inst, Sch Publ Hlth, Div Physiol, Baltimore, MD 21287 USA
[4] Johns Hopkins Med Inst, Sch Publ Hlth, Dept Med, Baltimore, MD 21287 USA
关键词
mouse; ventricular function; hemodynamics; conductance volumetry;
D O I
10.1152/ajpheart.1998.274.4.H1416
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The mouse is the species of choice for creating genetically engineered models of human disease. To study detailed systolic and diastolic left ventricular (LV) chamber mechanics in mice in vivo, we developed a miniaturized conductance-manometer system. alpha-Chloralose-urethananesthetized animals were instrumented with a two-electrode pressure-volume catheter advanced via the LV apex to the aortic root. Custom electronics provided time-varying conductances related to cavity volume. Baseline hemodynamics were similar to values in conscious animals: 634 +/- 14 beats/min, 112 +/- 4 mmHg, 5.3 +/- 0.8 mmHg, and 11,777 +/- 732 mmHg/s for heart rate, end-systolic and end-diastolic pressures, and maximum first derivative of ventricular pressure with respect to time (dP/dt(max)), respectively. Catheter stroke volume during preload reduction by inferior vena caval occlusion correlated with that by ultrasound aortic flow probe (r(2) = 0.98). This maneuver yielded end-systolic elastances of 79 +/- 21 mmHg/mu l, preload-recruitable stroke work of 82 +/- 5.6 mmHg, and slope of dP/dt(max)-end-diastolic volume relation of 699 +/- 100 mmHg.s(-1).mu l(-1), and these relations varied predictably with acute inotropic interventions. The control normalized time-varying elastance curve was similar to human data, further supporting comparable chamber mechanics between species. This novel approach should greatly help assess cardiovascular function in the blood-perfused murine heart.
引用
收藏
页码:H1416 / H1422
页数:7
相关论文
共 50 条
  • [31] EFFECT OF THE NORMAL, UNINSTRUMENTED PERICARDIUM ON LEFT-VENTRICULAR DIASTOLIC PRESSURE-VOLUME RELATIONS
    MISBACH, GA
    RINGERTZ, HG
    TYBERG, JV
    CIRCULATION, 1979, 60 (04) : 93 - 93
  • [32] Noninvasive means for preload reduction during analysis of left ventricular pressure-volume relations
    Haney, MF
    Goran, J
    Soren, H
    Bjorn, B
    CRITICAL CARE MEDICINE, 1999, 27 (12) : A85 - A85
  • [33] DETERMINATION OF LEFT-VENTRICULAR END-SYSTOLIC PRESSURE-VOLUME RELATIONSHIPS BY THE CONDUCTANCE (VOLUME) CATHETER TECHNIQUE
    KASS, DA
    YAMAZAKI, T
    BURKHOFF, D
    MAUGHAN, WL
    SAGAWA, K
    CIRCULATION, 1986, 73 (03) : 586 - 595
  • [34] PERICARDIAL PRESSURE AND THE LEFT-VENTRICULAR PRESSURE-VOLUME RELATIONSHIP
    OLDERSHAW, PJ
    SUTTON, MS
    KAY, P
    GIBSON, DG
    CLINICAL SCIENCE, 1981, 61 (03) : P34 - P35
  • [35] PRESSURE-VOLUME RELATIONS OF LEFT HEART CHAMBERS IN MAN
    BUNNELL, IL
    GRANT, C
    GREENE, DG
    FEDERATION PROCEEDINGS, 1962, 21 (02) : 135 - &
  • [36] SYSTOLIC PRESSURE-VOLUME RELATIONS OF LEFT-VENTRICLE
    SCHIERECK, P
    BOOM, HBK
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1976, 84 (03): : 557 - 559
  • [37] Left ventricular pressure-volume relationship in conscious mice
    Joho, Shuji
    Ishizaka, Shinji
    Sievers, Richard
    Foster, Elyse
    Simpson, Paul C.
    Grossman, William
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2007, 292 (01): : H369 - H377
  • [38] Impact of Stroke Volume Determination on Pressure-Volume Relations Measured by Conductance Catheter
    Wei, Chia-Ling
    Kan, Chung-Dann
    Wang, Jieh-Neng
    Wang, Yi-Wen
    Tsai, Mei-Ling
    2012 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): INTELLIGENT BIOMEDICAL ELECTRONICS AND SYSTEM FOR BETTER LIFE AND BETTER ENVIRONMENT, 2012, : 300 - 303
  • [39] Research on pressure-volume relations for the rabbit eye in vivo
    Zhang, Kun-Ya
    Cui, Qian-Qian
    Qian, Xiu-Qing
    Quan, Hai-Ying
    Liu, Zhi-Cheng
    Yiyong Shengwu Lixue/Journal of Medical Biomechanics, 2011, 26 (02): : 137 - 141
  • [40] Left ventricular pressure-volume relationship in conscious mice
    Joho, S
    Ishizaka, S
    Sievers, R
    Foster, E
    Simpson, PC
    Grossman, W
    CIRCULATION, 2004, 110 (17) : 729 - 729