Dual-energy CT-based iodine quantification to differentiate abdominal malignant lymphoma from lymph node metastasis

被引:24
|
作者
Martin, Simon S. [1 ]
Czwikla, Rouben [2 ]
Wichmann, Julian L. [1 ]
Albrecht, Moritz H. [1 ]
Lenga, Lukas [1 ]
Savage, Rock H. [3 ]
Arendt, Christophe [2 ]
Hammerstingl, Renate [2 ]
Vogl, Thomas J. [2 ]
Kaltenbach, Benjamin [2 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Div Expt & Translat Imaging, Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
Computed tomography; Diagnostic imaging; Lymphoma; Lymph nodes; Oncology; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RESPONSE CRITERIA; MULTIDETECTOR CT; CELL CARCINOMA; RENAL LESIONS; CANCER; TUMORS; ANGIOGRAPHY;
D O I
10.1016/j.ejrad.2018.06.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the value of dual-energy computed tomography (DECT)-derived iodine and fat quantification in differentiating malignant abdominal lymphoma from lymph node metastasis. Materials and methods: In this retrospective study, 59 patients (39 men; mean age, 62.7 years) with histopathologically-confirmed diagnosis of either malignant lymphoma or lymph node metastasis were included. For each lesion, contrast-enhanced attenuation, as well as DECT-derived iodine density and fat fraction measurements were recorded. Mean attenuation and material density values were compared between malignant lymphomas and lymph node metastases. The receiver operating characteristic (ROC) curve analysis was adopted to estimate the optimal threshold for discriminating between both entities. A control group (n = 60) was analyzed for comparison of attenuation and material density values of normal abdominal lymph nodes. Results: Assessment of DECT-derived iodine density and fat fraction values revealed significant differences between lymph node metastases (1.7 +/- 0.4 mg/ml and 15.5 +/- 7.3%) and malignant lymphomas (2.5 +/- 0.5 mg/ml and 26.7 +/- 12.2%) as well as normal lymph nodes (2.4 +/- 0.8 mg/ml and 24.1 +/- 10.8%) (P < 0.013). An iodine concentration of 2.0 mg/ml represented the optimal threshold to discriminate between lymphoma and lymph node metastasis (sensitivity, 87%; specificity, 89%). Moreover, a significant correlation was found between iodine concentration and fat fraction for both lymphomas and lymph node metastases (P = 0.001). Conclusion: DECT enables characterization of abdominal masses as derived iodine and fat fraction values differ significantly between malignant abdominal lymphomas and lymph node metastases.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 50 条
  • [11] Radiomics from dual-energy CT-derived iodine maps predict lymph node metastasis in head and neck squamous cell carcinoma
    Weiyuan Zhang
    Jin Liu
    Wenfeng Jin
    Ruihong Li
    Xiaojie Xie
    Wen Zhao
    Shuang Xia
    Dan Han
    La radiologia medica, 2024, 129 : 252 - 267
  • [12] Radiomics from dual-energy CT-derived iodine maps predict lymph node metastasis in head and neck squamous cell carcinoma
    Zhang, Weiyuan
    Liu, Jin
    Jin, Wenfeng
    Li, Ruihong
    Xie, Xiaojie
    Zhao, Wen
    Xia, Shuang
    Han, Dan
    RADIOLOGIA MEDICA, 2024, 129 (02): : 252 - 267
  • [13] Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
    Baxa, Jan
    Vondrakova, Alena
    Matouskova, Tana
    Ruzickova, Olga
    Schmidt, Bernhard
    Flohr, Thomas
    Sedlmair, Martin
    Ferda, Jiri
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1981 - 1988
  • [14] Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
    Jan Baxa
    Alena Vondráková
    Táňa Matoušková
    Olga Růžičková
    Bernhard Schmidt
    Thomas Flohr
    Martin Sedlmair
    Jiří Ferda
    European Radiology, 2014, 24 : 1981 - 1988
  • [15] Preoperative assessment in lymph node metastasis of pancreatic ductal adenocarcinoma: a transformer model based on dual-energy CT
    Xia Ding
    Wei Xu
    Yan Xu
    Yongchuang Zhang
    Huaxiao Xu
    Lin Guo
    Lei Li
    World Journal of Surgical Oncology, 23 (1)
  • [16] Dual-Energy CT: Lower Limits of Iodine Detection and Quantification
    Jacobsen, Megan C.
    Cressman, Erik N. K.
    Tamm, Eric P.
    Baluya, Dodge L.
    Duan, Xinhui
    Cody, Dianna D.
    Schellingerhout, Dawid
    Layman, Rick R.
    RADIOLOGY, 2019, 292 (02) : 414 - 419
  • [17] Preoperative Diagnosis of Regional Lymph Node Metastasis of Colorectal Cancer With Quantitative Parameters From Dual-Energy CT
    Yang, Zehong
    Zhang, Xiang
    Fang, Mengjie
    Li, Guolin
    Duan, Xiaohui
    Mao, Jiaji
    Shen, Jun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (01) : W17 - W25
  • [18] Radiomics from Primary Tumor on Dual-Energy CT Derived Iodine Maps can Predict Cervical Lymph Node Metastasis in Papillary Thyroid Cancer
    Zhou, Yan
    Su, Guo-Yi
    Hu, Hao
    Tao, Xin-Wei
    Ge, Ying-Qian
    Si, Yan
    Shen, Mei-Ping
    Xu, Xiao-Quan
    Wu, Fei-Yun
    ACADEMIC RADIOLOGY, 2022, 29 : S222 - S231
  • [19] Does dual-energy CT differentiate benign and malignant ovarian tumours?
    Elsherif, S. B.
    Zheng, S.
    Ganeshan, D.
    Iyer, R.
    Wei, W.
    Bhosale, P. R.
    CLINICAL RADIOLOGY, 2020, 75 (08) : 606 - 614
  • [20] Prognostic Value of Dual-Energy CT-Based Iodine Quantification versus Conventional CT in Acute Pulmonary Embolism: A Propensity-Match Analysis
    Im, Dong Jin
    Hur, Jin
    Han, Kyunghwa
    Suh, Young Joo
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Kim, Young Jin
    Choi, Byoung Wook
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (09) : 1095 - 1103