Dual-energy CT-based iodine quantification to differentiate abdominal malignant lymphoma from lymph node metastasis

被引:24
|
作者
Martin, Simon S. [1 ]
Czwikla, Rouben [2 ]
Wichmann, Julian L. [1 ]
Albrecht, Moritz H. [1 ]
Lenga, Lukas [1 ]
Savage, Rock H. [3 ]
Arendt, Christophe [2 ]
Hammerstingl, Renate [2 ]
Vogl, Thomas J. [2 ]
Kaltenbach, Benjamin [2 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Div Expt & Translat Imaging, Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[3] Med Univ South Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
Computed tomography; Diagnostic imaging; Lymphoma; Lymph nodes; Oncology; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RESPONSE CRITERIA; MULTIDETECTOR CT; CELL CARCINOMA; RENAL LESIONS; CANCER; TUMORS; ANGIOGRAPHY;
D O I
10.1016/j.ejrad.2018.06.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the value of dual-energy computed tomography (DECT)-derived iodine and fat quantification in differentiating malignant abdominal lymphoma from lymph node metastasis. Materials and methods: In this retrospective study, 59 patients (39 men; mean age, 62.7 years) with histopathologically-confirmed diagnosis of either malignant lymphoma or lymph node metastasis were included. For each lesion, contrast-enhanced attenuation, as well as DECT-derived iodine density and fat fraction measurements were recorded. Mean attenuation and material density values were compared between malignant lymphomas and lymph node metastases. The receiver operating characteristic (ROC) curve analysis was adopted to estimate the optimal threshold for discriminating between both entities. A control group (n = 60) was analyzed for comparison of attenuation and material density values of normal abdominal lymph nodes. Results: Assessment of DECT-derived iodine density and fat fraction values revealed significant differences between lymph node metastases (1.7 +/- 0.4 mg/ml and 15.5 +/- 7.3%) and malignant lymphomas (2.5 +/- 0.5 mg/ml and 26.7 +/- 12.2%) as well as normal lymph nodes (2.4 +/- 0.8 mg/ml and 24.1 +/- 10.8%) (P < 0.013). An iodine concentration of 2.0 mg/ml represented the optimal threshold to discriminate between lymphoma and lymph node metastasis (sensitivity, 87%; specificity, 89%). Moreover, a significant correlation was found between iodine concentration and fat fraction for both lymphomas and lymph node metastases (P = 0.001). Conclusion: DECT enables characterization of abdominal masses as derived iodine and fat fraction values differ significantly between malignant abdominal lymphomas and lymph node metastases.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 50 条
  • [1] Diagnostic accuracy of dual-energy CT-based nomograms to predict lymph node metastasis in gastric cancer
    Jing Li
    Mengjie Fang
    Rui Wang
    Di Dong
    Jie Tian
    Pan Liang
    Jie Liu
    Jianbo Gao
    European Radiology, 2018, 28 : 5241 - 5249
  • [2] Diagnostic accuracy of dual-energy CT-based nomograms to predict lymph node metastasis in gastric cancer
    Li, Jing
    Fang, Mengjie
    Wang, Rui
    Dong, Di
    Tian, Jie
    Liang, Pan
    Liu, Jie
    Gao, Jianbo
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 5241 - 5249
  • [3] Dual-Energy CT of Rectal Cancer Specimens: A CT-based Method for Mesorectal Lymph Node Characterization
    al-Najami, Issam
    Beets-Tan, Regina G. H.
    Madsen, Gunvor
    Baatrup, Gunnar
    DISEASES OF THE COLON & RECTUM, 2016, 59 (07) : 640 - 647
  • [4] Dual-energy CT-based deep learning radiomics can improve lymph node metastasis risk prediction for gastric cancer
    Li, Jing
    Dong, Di
    Fang, Mengjie
    Wang, Rui
    Tian, Jie
    Li, Hailiang
    Gao, Jianbo
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2324 - 2333
  • [5] Dual-energy CT-based iodine quantification for differentiating pulmonary artery sarcoma from pulmonary thromboembolism: a pilot study
    Suyon Chang
    Jin Hur
    Dong Jin Im
    Young Joo Suh
    Yoo Jin Hong
    Hye-Jeong Lee
    Young Jin Kim
    Byoung Wook Choi
    European Radiology, 2016, 26 : 3162 - 3170
  • [6] Dual-energy CT-based iodine quantification for differentiating pulmonary artery sarcoma from pulmonary thromboembolism: a pilot study
    Chang, Suyon
    Hur, Jin
    Im, Dong Jin
    Suh, Young Joo
    Hong, Yoo Jin
    Lee, Hye-Jeong
    Kim, Young Jin
    Choi, Byoung Wook
    EUROPEAN RADIOLOGY, 2016, 26 (09) : 3162 - 3170
  • [7] Performance of dual-energy CT with iodine quantification in differentiating for benign versus malignant lymph nodes in patients with lung adenocarcinoma
    Arachchige, Arosh S. Perera Molligoda
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (07) : 798 - 798
  • [8] Accessory spleen versus lymph node: Value of iodine quantification with dual-energy computed tomography
    Winklhofer, Sebastian
    Lin, Wei-Ching
    Lambert, Jack W.
    Yeh, Benjamin M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 53 - 58
  • [9] Dual-Energy CT Material Decomposition: The Value in the Detection of Lymph Node Metastasis from Breast Cancer
    Yel, Ibrahim
    D'Angelo, Tommaso
    Gruenewald, Leon D.
    Koch, Vitali
    Golbach, Rejane
    Mahmoudi, Scherwin
    Ascenti, Giorgio
    Blandino, Alfredo
    Vogl, Thomas J.
    Booz, Christian
    Bucolo, Giuseppe M.
    DIAGNOSTICS, 2024, 14 (05)
  • [10] Dual-Energy CT-Based Monochromatic Imaging
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S9 - S15