A Novel Flow Dynamics Study of the Intracranial Veins Using Whole Brain Four-Dimensional Computed Tomography Angiography

被引:3
|
作者
Mizutani, Katsuhiro [1 ,2 ]
Arai, Nobuhiko [1 ]
Toda, Masahiro [1 ]
Akiyama, Takenori [1 ]
Fujiwara, Hirokazu [3 ]
Jinzaki, Masahiro [3 ]
Yoshida, Kazunari [1 ]
机构
[1] Keio Univ, Dept Neurosurg, Sch Med, Tokyo, Japan
[2] Hop Foch, Serv Neuroradiol Diagnost & Therapeut, Suresnes, France
[3] Keio Univ, Dept Radiol, Sch Med, Tokyo, Japan
关键词
4D-CTA; Flow direction; Flow dynamics; Flow velocity; Intracranial vein; DURAL ARTERIOVENOUS-FISTULAS; VENOUS-BLOOD FLOW; VELOCITY;
D O I
10.1016/j.wneu.2019.07.109
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The flow dynamics of the intracranial venous channels are fundamentally important for understanding intracranial physiology and pathophysiology. However, the method clinically applicable to the evaluation of the flow dynamics of the intracranial venous system has not been well described in the reported data. We have developed a new method to evaluate intracranial venous flow direction and velocity using 4-dimensional (4D) computed tomography angiography (CTA). The aim of the present study was to verify the accuracy and validity of 4D-CTA in a clinical setting. METHODS: We retrospectively analyzed 97 veins from 26 patients (16 cases of arteriovenous shunt disease, 9 intracranial tumor cases, and 1 cerebral aneurysm case) who had undergone both 4D-CTA and conventional digital subtraction angiography (DSA). Using 4D-CTA, we analyzed the time-density curve with gamma distribution extrapolation and obtained the direction of the flow and flow velocity of each vein. The direction of the flow in 4D-CTA was also collated with that obtained using conventional DSA to verify the experimental method. RESULTS: The direction of the flow determined by 4D-CTA was consistent with that of conventional DSA in 94.8% of cases. The average venous flow velocity was 64.3 mm/ second and 81.8 mm/second, respectively, in the antegrade and retrograde channels affected by arteriovenous shunts. CONCLUSIONS: The present flow analysis using 4D-CTA enabled us to evaluate the direction and velocity of intracranial venous flow. Other than some limitations, the presented method is reliable and its potential for application in clinical settings is promising.
引用
收藏
页码:E176 / E185
页数:10
相关论文
共 50 条
  • [31] Initial evaluation of a four-dimensional computed tomography system, using a programmable motor
    Simon, Luc
    Giraud, Philippe
    Servois, Vincent
    Rosenwald, Jean-Claude
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2006, 7 (04): : 50 - 65
  • [32] Automated analysis of trapeziometacarpal joint kinematics using four-dimensional computed tomography
    Van Royen, Kjell
    Keelson, Benyameen
    Jager, Tjeerd
    Buls, Nico
    Scheerlinck, Thierry
    Cattrysse, Erik
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2024, 49 (09) : 1095 - 1103
  • [33] Kinematics of the wrist in Kienbock's disease: a four-dimensional computed tomography study
    MacLean, Simon B. M.
    Bain, Gregory I.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2021, 46 (05) : 504 - 509
  • [34] NOVEL ASSESSMENT OF RENAL MOTION IN CHILDREN AS MEASURED VIA FOUR-DIMENSIONAL COMPUTED TOMOGRAPHY
    Panandiker, Atmaram S. Pai
    Sharma, Shelly
    Naik, Mihir H.
    Wu, Shengjie
    Hua, Chiaho
    Beltran, Chris
    Krasin, Matthew J.
    Merchant, Thomas E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1771 - 1776
  • [35] Analysis of whole breast displacement relative to selected skin markers and surgical clips using four-dimensional computed tomography
    Wang, Wei
    Li, Jianbin
    Xu, Min
    Shao, Qian
    Zhang, Yingjie
    Fan, Tingyong
    Shang, Dongping
    Li, Fengxiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (03): : 6483 - 6489
  • [36] Analysis of Whole Breast Displacement Relative to Selected Skin Markers and Surgical Clips using Four-dimensional Computed Tomography
    Wei, W.
    Jianbin, L.
    Suzhen, W.
    Min, X.
    Yingjie, Z.
    Tingyong, F.
    Qian, S.
    Fengxiang, L.
    Dongping, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S838 - S838
  • [37] Preoperative Diagnosis of Suprasellar Hemangioblastoma with Four-Dimensional Computed Tomography Angiography: Case Report and Literature Review
    Tong, Yi
    Sirhan, Denis
    Cortes, Maria
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2021, 31 (02): : 499 - 509
  • [38] Estimating Pulsatile Flow Velocity using Four-Dimensional Digital Subtraction Angiography
    Chen, Ko-Kung
    Lin, Chung-Jung
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [39] True four-dimensional analysis of thoracic aortic displacement and distension using model-based segmentation of computed tomography angiography
    Weber, Tim F.
    Mueller, Tobias
    Biesdorf, Andreas
    Woerz, Stefan
    Rengier, Fabian
    Heye, Tobias
    Holland-Letz, Tim
    Rohr, Karl
    Kauczor, Hans-Ulrich
    von Tengg-Kobligk, Hendrik
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (01): : 185 - 194
  • [40] True four-dimensional analysis of thoracic aortic displacement and distension using model-based segmentation of computed tomography angiography
    Tim F. Weber
    Tobias Müller
    Andreas Biesdorf
    Stefan Wörz
    Fabian Rengier
    Tobias Heye
    Tim Holland-Letz
    Karl Rohr
    Hans-Ulrich Kauczor
    Hendrik von Tengg-Kobligk
    The International Journal of Cardiovascular Imaging, 2014, 30 : 185 - 194