Characterization of Schottky-diode X/γ-ray detectors based on CdTe crystals with different uncompensated impurity concentrations

被引:4
|
作者
Sklyarchuk, Valeriy [1 ]
Gnatyuk, Volodymyr [2 ]
Fochuk, Petro [1 ]
Aoki, Toru [3 ]
机构
[1] Yuriy Fedkovych Chernivtsi Natl Univ, Kotsyubynskyi Str 2, UA-58012 Chernovtsy, Ukraine
[2] Natl Acad Sci Ukraine, VE Lashkaryov Inst Semicond Phys, Prospekt Nauky 41, UA-03028 Kiev, Ukraine
[3] Shizuoka Univ, Inst Elect, 3-5-1 Johoku, Naka Ku, Hamamatsu 4328011, Japan
关键词
CdTe semiconductor; Schottky diode; Depletion region width; Impurity concentration; Charge transport; I-V characteristics; X/gamma-ray detector; Radioisotope emission spectra; Detection efficiency; Energy resolution; DEFECT FORMATION;
D O I
10.1016/j.nima.2021.166229
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Schottky-diode X/.. -ray detectors based on semi-insulating p-like CdTe single crystals with four values of uncompensated impurity concentration (N approximate to 2 x 10(12) cm(-3), 2 x 10(11) cm(-3), 1 x 10(11) cm(-3), 4 x 10(10) cm(-3)) were developed and characterized by I-V measurements at low reverse bias (0.005-100 V) and detection of Cs-137 and Am-241 radioisotope emission spectra. All the detectors were fabricated by the same technique using vacuum evaporation of a Cr electrode (rectifying contact) and chemical deposition of an Au electrode (Ohmic contact) onto the B- and A-face of CdTe(111) crystals, respectively, pre-treated with Ar-ion bombardment. The change of the charge transport mechanism from over-barrier (thermionic) to generation current along with the analysis of the temperature dependence of the differential resistivity evidenced a high concentration of deep level impurities near the middle of the semiconductor bandgap. The detection efficiency eta of the detectors was calculated using the corrected expressions for the coordinate dependence of the electrical field strength in a diode which took into account the fact that the depletion region width exceeded the CdTe crystal thickness at higher bias voltages. It was shown that the dependence eta(N) decreased with increasing N without a maximum corresponding to an optimal value N-opt as reported earlier. The Cr/CdTe/Au Schottkydiode detectors, fabricated using CdTe with the lowest N, demonstrated the highest energy resolution (0.6% @662 keV and 7.5% @59.5 keV) and it degraded when crystals with higher N were used.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Concentration of uncompensated impurities as a key parameter of CdTe and CdZnTe crystals for Schottky diode x/γ-ray detectors
    Kosyachenko, L. A.
    Lambropoulos, C. P.
    Aoki, T.
    Dieguez, E.
    Fiederle, M.
    Loukas, D.
    Sklyarchuk, O. V.
    Maslyanchuk, O. L.
    Grushko, E. V.
    Sklyarchuk, V. M.
    Crocco, J.
    Bensalah, H.
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2012, 27 (01)
  • [2] Features of electrical and spectrometric properties of series connected CdTe-based Schottky-diode X/γ-ray detectors
    Sklyarchuk, Valeriy
    Gnatyuk, Volodymyr
    Aoki, Toru
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXIV, 2022, 12241
  • [3] Effect of the thickness of CdTe crystals on electrical and detection properties of Cr/CdTe/Au Schottky-diode detectors
    Sklyarchuk, Valery M.
    Gnatyuk, Volodymyr A.
    Fang, Xiaodong
    Aoki, Toru
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114
  • [4] Effect of CdTe crystal thickness on the efficiency of Cr/CdTe/Au Schottky-diode detectors
    Sklyarchuk, V. M.
    Gnatyuk, V. A.
    Aoki, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 953
  • [5] CdTe-based Schottky diode X-ray detectors for medical imaging
    Gnatyuk, V. A.
    Vlasenko, O. I.
    Kosyachenko, L. A.
    Maslyanchuk, O. L.
    Sklyarchuk, V. M.
    Grushko, E. V.
    Aoki, T.
    8TH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2008, 7008
  • [6] Optimal width of barrier region in X/γ-ray Schottky diode detectors based on CdTe and CdZnTe
    Kosyachenko, L. A.
    Aoki, T.
    Lambropoulos, C. P.
    Gnatyuk, V. A.
    Melnychuk, S. V.
    Sklyarchuk, V. M.
    Grushko, E. V.
    Maslyanchuk, O. L.
    Sklyarchuk, O. V.
    JOURNAL OF APPLIED PHYSICS, 2013, 113 (05)
  • [7] Depletion Region in Cr/CdTe/Au Schottky Diode X- and γ-Ray Detectors
    Sklyarchuk, V. M.
    Gnatyuk, V. A.
    Aoki, T.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (09) : 2140 - 2144
  • [8] High Energy Resolution CdTe Schottky Diode γ-Ray Detectors
    Kosyachenko, L. A.
    Aoki, T.
    Lambropoulos, C. P.
    Gnatyuk, V. A.
    Grushko, E. V.
    Sklyarchuk, V. M.
    Maslyanchuk, O. L.
    Sklyarchuk, O. F.
    Koike, A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (04) : 2845 - 2852
  • [9] High Energy Resolution CdTe Schottky Diode γ-Ray Detectors
    Kosyachenko, V. L. A.
    Aoki, T.
    Lambropoulos, C. P.
    Gnatyuk, V. A.
    Grushko, E. V.
    Sklyarchuk, V. M.
    Maslyanchuk, O. L.
    Sklyarchuk, O. F.
    Koike, A.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4156 - 4164
  • [10] Spectrometric properties of single and series-connected Cr/CdTe/Au Schottky-diode detectors
    Sklyarchuk, Valeriy
    Gnatyuk, Volodymyr
    Aoki, Tom
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXVI, 2024, 13151