Features of electrical and spectrometric properties of series connected CdTe-based Schottky-diode X/γ-ray detectors

被引:1
|
作者
Sklyarchuk, Valeriy [1 ]
Gnatyuk, Volodymyr [2 ]
Aoki, Toru [3 ]
机构
[1] Yuriy Fedkovych Chernivtsi Natl Univ, Kotsyubynsky Str 2, UA-58012 Chernovtsy, Ukraine
[2] Natl Acad Sci Ukraine, VE Lashkaryov Inst Semicond Phys, Prospekt Nauky 41, UA-03028 Kiev, Ukraine
[3] Shizuoka Univ, Res Inst Elect, 3-5-1 Johoku,Naka Ku, Hamamatsu, Shizuoka 4328011, Japan
关键词
CdTe crystals; rectifying contact; Schottky diode; X/gamma-ray detector; parallel and series connected detectors; I-V characteristic; detection efficiency; energy resolution;
D O I
10.1117/12.2633457
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The electrical and spectroscopic characteristics of the ionizing radiation detectors, designed as Ti/CdTe/Au diodes with a rectifying barrier were investigated. Schottky (Ti/CdTe) and ohmic (Au/CdTe) contacts were formed on the B- and A-faces of detector-grade p-CdTe(111) crystals subjected to Ar plasma treatment. Owing to the advantages of the fabrication technique, the Ti/CdTe/Au Schottky-diode X/gamma-ray detectors with similar parameters were obtained. The features of the single detector and stacks of two mounted detectors, connected in parallel or series, were analyzed. The measurements of the I-V characteristics showed that the sensor, consisting of two series-connected detectors, has lower dark current and significantly the weakened effect of space-charge-limited currents (SCLC) than the single detector or two parallel-connected detectors. The stack of the detectors connected in parallel has higher photosensitivity but lower energy resolution compared with those characteristics of the single detector. The analysis of the emission spectra of Cs-137 and Am-241 isotopes, measured at room temperature, showed that the sensitivity of the stack of the series-connected detectors turned out to be the highest. However, the double peaks were observed in the isotope spectra taken with such detector stack that was unusual and attributed to features of the electronic signal processing. Series connection of detectors has the advantages as reducing the dark current and decreasing the stack capacitance. To implement these features and optimally use such connection, specific electronic devices are needed, in particular to combine two charge packets which are formed by the detector stack into one with a larger amplitude.
引用
收藏
页数:7
相关论文
共 31 条
  • [1] Spectrometric properties of single and series-connected Cr/CdTe/Au Schottky-diode detectors
    Sklyarchuk, Valeriy
    Gnatyuk, Volodymyr
    Aoki, Tom
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXVI, 2024, 13151
  • [2] CdTe-based Schottky diode X-ray detectors for medical imaging
    Gnatyuk, V. A.
    Vlasenko, O. I.
    Kosyachenko, L. A.
    Maslyanchuk, O. L.
    Sklyarchuk, V. M.
    Grushko, E. V.
    Aoki, T.
    8TH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2008, 7008
  • [3] Characterization of Schottky-diode X/γ-ray detectors based on CdTe crystals with different uncompensated impurity concentrations
    Sklyarchuk, Valeriy
    Gnatyuk, Volodymyr
    Fochuk, Petro
    Aoki, Toru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [4] Effect of the thickness of CdTe crystals on electrical and detection properties of Cr/CdTe/Au Schottky-diode detectors
    Sklyarchuk, Valery M.
    Gnatyuk, Volodymyr A.
    Fang, Xiaodong
    Aoki, Toru
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XXI, 2019, 11114
  • [5] Enhanced X/γ-Ray Detection Efficiency in CdTe-based Schottky Diode Detectors Operated in a Stacked Mode
    Gnatyuk, Volodymyr A.
    Zelenska, Kateryna S.
    Sklyarchuk, Valery M.
    Aoki, Toru
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [6] Charge transport features of CdTe-based X- and γ-ray detectors with Ti and TiOx Schottky contacts
    Maslyanchuk, Olena
    Solovan, Mykhailo
    Brus, Viktor
    Maryanchuk, Pavlo
    Maistruk, Eduard
    Fodchuk, Ihor
    Gnatyuk, Volodymyr
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 988
  • [7] Characteristics and Stability of Diode Type CdTe-based X-Ray and Gamma-Ray Detectors
    Gnatyuk, V. A.
    Vlasenko, O. I.
    Aoki, T.
    Koike, A.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [8] Performance of CdTe-based p-n junction-diode X/γ-ray detectors
    Gnatyuk, Volodymyr
    Levytskyi, Serhii
    Maslyanchuk, Olena
    Kulyk, Oleksandr
    Aoki, Toru
    FIFTEENTH INTERNATIONAL CONFERENCE ON CORRELATION OPTICS, 2021, 12126
  • [9] Possibilities of CdTe-based X/γ-ray Detectors with MoOx Contacts
    Maslyanchuk, O. L.
    Solovan, M. M.
    Kulchynsky, V. V.
    Brus, V. V.
    Maryanchuk, P. D.
    Fodchuk, I. M.
    Gnatyuk, V. A.
    Aoki, T.
    Potiriadis, C.
    Kaissas, Y.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [10] Effect of the concentration of uncompensated impurities on the properties of CdTe-based X- and γ-ray detectors
    Kosyachenko, L. A.
    Sklyarchuk, V. M.
    Melnychuk, S. V.
    Maslyanchuk, O. L.
    Grushko, E. V.
    Sklyarchuk, O. V.
    SEMICONDUCTORS, 2012, 46 (03) : 374 - 381