Buoyancy Driven Natural Ventilation through Horizontal Openings

被引:0
|
作者
Heiselberg, Per [1 ]
Li, Zhigang [2 ]
机构
[1] Univ Aalborg, Dept Civil Engn, Div Architectural Engn, Aalborg, Denmark
[2] Danfoss AS, Nordborg, Denmark
关键词
natural ventilation; airflow rate; buoyancy; horizontal opening; tracer gas; LES; EXCHANGE FLOW;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study of the phenomenon of buoyancy driven natural ventilation through single-sided horizontal openings was performed in a full-scale laboratory test rig. The measurements were made for opening ratios L/D ranging from 0.027 to 4.455, where L and D are the length of the opening and the diameter of the opening, respectively. The basic nature of airflow through single-sided openings, including airflow rate, air velocity, temperature difference between the rooms and the dimensions of the horizontal openings, were measured. A bi-directional airflow rate was measured using the constant injection tracer gas technique. Smoke visualizations showed that the airflow patterns are highly transient and unstable, and that the airflow rate oscillates with time. Correlations between the Froude (Archimedes) number Fr (Ar) and the L/D ratio are presented. In some cases the measured airflow rates fit quite well with the Epstein's formula but in other cases the measured data show clear deviations from the Epstein's formula. Thus, revised formulas for natural ventilation are proposed.
引用
收藏
页码:219 / 231
页数:13
相关论文
共 50 条
  • [31] Evolution Characteristics of Indoor Pollutant Concentration in Buoyancy-Driven Natural Ventilation
    Zhuang J.
    Diao Y.
    Zhang L.
    Shen H.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2021, 56 (01): : 47 - 55
  • [32] EXPERIMENTAL INVESTIGATION ON SINGLE-SIDED TRANSIENT NATURAL VENTILATION DRIVEN BY BUOYANCY
    Vadugapalayam Rangasamy, Lenin
    Sivanathan, Sivalakshmi
    Muthu, Raja
    THERMAL SCIENCE, 2017, 21 : S489 - S496
  • [33] CFD simulation on buoyancy-driven natural ventilation of a room with a heated floor
    Tan, G
    Glicksman, L
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 198 - 204
  • [34] Buoyancy-driven natural ventilation characteristics of thermal corridors in industrial buildings
    Pu, Jing
    Yuan, Yanping
    Jiang, Fujian
    Zheng, Kaijie
    Zhao, Kaiming
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [35] Analysis of natural cross-ventilation in buildings driven by wind and buoyancy forces
    Liu, Jing
    Shui, Taotao
    Ma, Fei
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3001 - 3004
  • [36] Buoyancy driven ventilation in tropical greenhouses
    Montero, JI
    Antón, A
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE AND BRITISH-ISRAELI WORKSHOP ON GREENHOUSE TECHNIQUES TOWARDS THE 3RD MILLENNIUM, 2000, (534): : 41 - 48
  • [37] Experimental investigation on single-sided transient natural ventilation driven by buoyancy
    Vadugapalayam Rangasamy L.
    Sivanathan S.
    Muthu R.
    Vadugapalayam Rangasamy, Lenin (leninrangasamy@gmail.com), 2017, Serbian Society of Heat Transfer Engineers (21): : 489 - 496
  • [38] A review on natural ventilation applications through building facade components and ventilation openings in tropical climates
    Aflaki, Ardalan
    Mahyuddin, Norhayati
    Mahmoud, Zakaria Al-Cheikh
    Baharum, Mohamad Rizal
    ENERGY AND BUILDINGS, 2015, 101 : 153 - 162
  • [39] Buoyancy-driven exchange flow through double openings with having multi flow patterns
    Tsuru, D
    Okamoto, K
    Madarame, H
    Fumizawa, M
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1998, 41 (04) : 781 - 787
  • [40] The fluid mechanics of natural ventilation-displacement ventilation by buoyancy-driven flows assisted by wind
    Department of Applied Mathematics, University of Cambridge, Silver Street, Cambridge, CB3 9EW, United Kingdom
    Build. Environ., 6 (707-720):