Integrated enzyme with stimuli-responsive coordination polymer for personal glucose meter-based portable immunoassay

被引:6
|
作者
Gao, Liping [1 ]
Li, Yong [1 ]
Huang, Zhen-Zhong [1 ]
Tan, Hongliang [1 ,2 ]
机构
[1] Jiangxi Normal Univ, Coll Chem & Chem Engn, Key Lab Chem Biol Jiangxi Prov, Nanchang 330022, Jiangxi, Peoples R China
[2] Huaihua Univ, Coll Biol & Food Engn, Huaihua 418000, Peoples R China
基金
中国国家自然科学基金;
关键词
Coordination polymer; Carcinoembryonic antigen; Enzyme immobilization; Immunoassay; Personal glucose meter; METAL-ORGANIC FRAMEWORKS; IN-SITU SYNTHESIS; ALKALINE-PHOSPHATASE; FLUORESCENT ASSAY; QUANTITATIVE DETECTION; HIGH-SENSITIVITY; LOW-COST; NANOPARTICLES; STRATEGY; BIOMOLECULES;
D O I
10.1016/j.aca.2022.339774
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Coordination polymers (CPs) with tunable structures and properties have been extensively explored in a variety of fields. In this work, we demonstrated the potential of stimuli-responsive CPs as a host of integrating enzymes to construct a portable immunoassay. By employing terbium ion (Tb3+) as a metal node and guanine monophosphate (GMP) as a bridge ligand, an alkaline phosphatase (ALP)-responsive Tb/GMP CPs was fabricated, which allows amyloglucosidase (GA) to be integrated to form GA@Tb/GMP composite. Owing to the size-selectivity of Tb/GMP CPs as a host, the loaded GA was physically isolated from its substrate starch. However, Tb/GMP CPs is highly sensitive to ALP, which can hydrolyze the phosphate group of GMP to destroy the structure of Tb/GMP CPs, leading to the release of GA from GA@Tb/GMP composite. The released GA can digest starch to produce glucoses and give a measured signal by personal glucose meter (PGM). This finding leads to a PGM-based portable immunoassay for the quantitative analysis of carcinoembryonic antigen (CEA), and satisfactory results with a detection limit of 0.28 ng/mL have been achieved. The successful determination of CEA in serum samples demonstrates its potential in practical application. We believe that this work can provide a remarkable insight for the rational design of stimuli-responsive CPs for a wide of applications. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Stimuli-Responsive Materials Based on Interpenetrating Polymer Liquid Crystal Hydrogels
    Stumpel, Jelle E.
    Gil, Elda Renedo
    Spoelstra, Anne B.
    Bastiaansen, Cees W. M.
    Broer, Dirk J.
    Schenning, Albertus P. H. J.
    ADVANCED FUNCTIONAL MATERIALS, 2015, 25 (22) : 3314 - 3320
  • [22] Stimuli-Responsive Bio-Based Surfactant-Polymer Gels
    Akin-Ige, Foluso
    Amin, Samiul
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2024, 703
  • [23] Dual stimuli-responsive phosphorescence of a Pb(ii) coordination polymer to acidic vapors and thermal treatment
    Tunsrichon, Sujitra
    Chainok, Kittipong
    Promarak, Vinich
    Arunlimsawat, Suangsiri
    Youngme, Sujittra
    Boonmak, Jaursup
    DALTON TRANSACTIONS, 2023, 52 (08) : 2209 - 2213
  • [24] Effects of Steam Sterilization on the Properties of Stimuli-Responsive Polymer-Based Hydrogels
    Ferreira, Ines
    Marques, Ana Camila
    Costa, Paulo Cardoso
    Amaral, Maria Helena
    GELS, 2023, 9 (05)
  • [25] Polymer-Based Stimuli-Responsive Recyclable Catalytic Systems for Organic Synthesis
    Zhang, Jingli
    Zhang, Mingxi
    Tang, Kangjian
    Verpoort, Francis
    Sun, Taolei
    SMALL, 2014, 10 (01) : 32 - 46
  • [26] Stimuli-Responsive Guest Binding and Releasing by Dendritic Polymer-Based Hydrogels
    Yasumasa Kanekiyo
    Hiroaki Tao
    Börje Sellergren
    Polymer Journal, 2008, 40 : 684 - 687
  • [27] Stimuli-Responsive Guest Binding and Releasing by Dendritic Polymer-Based Hydrogels
    Kanekiyo, Yasumasa
    Tao, Hiroaki
    Sellergren, Boerje
    POLYMER JOURNAL, 2008, 40 (08) : 684 - 687
  • [28] A Catechol-Meter Based on Conventional Personal Glucose Meter for Portable Detection of Tyrosinase and Sodium Benzoate
    Tian, Tao
    Zhang, Wei-Yi
    Zhou, Hang-Yu
    Peng, Li-Jing
    Zhou, Xi
    Zhang, Hao
    Yang, Feng-Qing
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [29] Portable pH meter-based competitive immunoassay of E-selectin using urease-encapsulated metal-organic frameworks
    Xie, Yiyan
    He, Xianhuan
    Yu, Rujie
    Jin, Yuhe
    Tan, Liang
    TALANTA, 2025, 287
  • [30] Stimuli-responsive chymotrypsin conjugates synthesized using polymer-based protein engineering
    Cummings, Chad
    Murata, Hironobu
    Russell, Alan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249