Optimizing rotating gamma camera PET for brain imaging

被引:0
|
作者
Turkington, TG [1 ]
机构
[1] Duke Univ, Med Ctr, Durham, NC 27710 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several acquisition geometries were investigated to optimize coincidence count rates and coincidnce/singles rate ratios for brain imaging on a rotating gamma camera PET system. Detection efficiency and singles count rate limits on these systems dictate that keeping unused singles from hitting the cameras should improve coincidence rates if radiotracer doses can be adjusted to match the singles detection efficiency of the system. Radius of rotation and camera field of view were adjusted within the constraints of patient positioning. Acquisitions were done with transaxial septa and with graded absorber alone. Phantoms included a Ge-68 pin source and an extended head-thorax phantom with F-18 solution. Coincidence detection efficiency was best for the absorber only, with a small radius of rotation. Coincidence/singles ratio was best for graded absorber with small radius of rotation and axial camera field limited to 27 cm. The septa yielded a slightly low coincidence/singles ratio, but their reduction of scatter and restriction of incidence angle of detected photons (leading to higher spatial resolution) makes their use favorable.
引用
收藏
页码:1465 / 1469
页数:3
相关论文
共 50 条
  • [1] Optimizing rotating gamma camera PET for brain imaging
    Turkington, TG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1196 - 1201
  • [2] Computer phantom study of brain PET glucose metabolism imaging using a rotating SPECT/PET camera
    McGoron, AJ
    Mao, XM
    Georgiou, MF
    Kuluz, JW
    COMPUTERS IN BIOLOGY AND MEDICINE, 2005, 35 (06) : 511 - 531
  • [3] ROUTINE SPECT IMAGING WITH THE ROTATING GAMMA-CAMERA
    BERGMANN, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1985, 11 (2-3): : A48 - A48
  • [4] PET imaging using gamma camera systems: A review
    Jarritt, PH
    Acton, PD
    NUCLEAR MEDICINE COMMUNICATIONS, 1996, 17 (09) : 758 - 766
  • [5] Mind-Tracker PET: A wearable PET camera for brain imaging
    Xu, Jianfeng
    Zhao, Zhixiang
    Xie, Siwei
    Shi, Dawei
    Huang, Qiu
    Peng, Qiyu
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [6] Cardiac imaging with gamma camera coincidence (hybrid) PET.
    Smith, MF
    Brown, BP
    Driver, DR
    Dilsizian, V
    Schraml, FV
    Carson, JM
    Bacharach, SL
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 178P - 178P
  • [7] Physical evaluation of 511 keV imaging with gamma camera and PET
    Vandenberghe, S
    D'Asseler, Y
    Koole, M
    Monsieurs, M
    Van de Walle, R
    Lemahieu, I
    Dierckx, RA
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1057 - 1061
  • [8] PET imaging using a triple-head gamma camera
    Kuikka, JT
    Sohlberg, A
    Husso-Saastamoinen, M
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2002, 22 (05) : 328 - 331
  • [9] Optimisation of noise equivalent count rates for brain and body FDG imaging using gamma camera PET
    Univ Coll Medical Sch, London, United Kingdom
    IEEE Nucl Sci Symp Med Imaging Conf, (1463-1469):
  • [10] Optimisation of noise equivalent count rates for brain and body FDG imaging using gamma camera PET
    Visvikis, D
    Fryer, T
    Downey, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 624 - 630