摘要
This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.
引用
收藏
页码:443 / 446
页数:4
相关论文
共 50 条
  • [31] A parameter identification model for the Photovoltaic grid-connected inverter
    Xu, Yan
    Jin, Weijia
    OPTIK, 2017, 142 : 23 - 32
  • [32] Integrated Zeta Inverter Applied in a Single-Phase Grid-Connected Photovoltaic System
    Sampaio, Leonardo Poltronieri
    Oliveira da Silva, Sergio Augusto
    Silva Costa, Paulo Junior
    2019 IEEE 15TH BRAZILIAN POWER ELECTRONICS CONFERENCE AND 5TH IEEE SOUTHERN POWER ELECTRONICS CONFERENCE (COBEP/SPEC), 2019,
  • [33] Modeling and stability analysis of a photovoltaic grid-connected inverter integrated with an energy storage system
    Shen, Fu
    Li, Shiwei
    Wang, Jian
    Fu, Yu
    Yang, Guangbing
    Zhang, Wei
    Zhai, Suwei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2024, 52 (19): : 131 - 143
  • [34] Sizing verification of photovoltaic array and grid-connected inverter ratio for the Malaysian building integrated photovoltaic project
    Omar, Ahmad Maliki
    Shaari, Sulaiman
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2009, 4 (04) : 254 - 257
  • [35] Stability analysis of CHB photovoltaic grid-connected inverter in weak grid
    Yang S.
    Zhang X.
    Mao W.
    Hu Y.
    Wang M.
    Wang F.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (01): : 398 - 405
  • [36] Research of Grid-Connected Photovoltaic Inverter Grid-Connected System Based on Dual Closed-Loop of Grid Voltage Vector Orientation
    Han, Qihang
    Li, Bo
    Li, Zixuan
    Ke, Qin
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 5171 - 5176
  • [37] Grid-Connected Photovoltaic System Based on a Cascaded H-Bridge Inverter
    Rezaei, Mohammad-Ali
    Iman-Eini, Hossein
    Farhangi, Shahrokh
    JOURNAL OF POWER ELECTRONICS, 2012, 12 (04) : 578 - 586
  • [38] Modeling, control and analysis of cascaded inverter based grid-connected photovoltaic system
    Kumar, Nayan
    Saha, Tapas Kumar
    Dey, Jayati
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 78 : 165 - 173
  • [39] Research on Photovoltaic Grid-Connected Inverter Based on Fuzzy Hystersis Current Controller
    Gao, Jinfeng
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [40] Frequency conversion control of photovoltaic grid-connected inverter based on LCL filtering
    Xiao, Dongyue
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (04) : 1341 - 1347