Plain versus paclitaxel-coated balloon angioplasty in arteriovenous fistula and graft stenosis: An umbrella review

被引:14
|
作者
Lazarides, Miltos K. [1 ]
Christaina, Eleni [2 ]
Antoniou, George A. [3 ]
Argyriou, Christos [1 ]
Trypsianis, Gregory [2 ]
Georgiadis, George S. [1 ]
机构
[1] Democritus Univ, Dept Vasc Surg, Alexandroupolis, Greece
[2] Democritus Univ, Dept Biostat, Alexandroupolis, Greece
[3] Univ Manchester, Royal Oldham Hosp, Pennine Acute Hosp NHS Trust, Dept Vasc & Endovasc Surg, Manchester, Lancs, England
来源
JOURNAL OF VASCULAR ACCESS | 2022年 / 23卷 / 06期
关键词
AV fistula; dialysis access; interventional radiology; paclitaxel; umbrella review; balloon angioplasty; systematic review; DRUG-ELUTING BALLOON; HEMODIALYSIS ACCESS; SYSTEMATIC REVIEWS; METHODOLOGICAL QUALITY; METAANALYSIS; AMSTAR;
D O I
10.1177/11297298211005290
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
An umbrella review was performed to synthesize the evidence from systematic reviews/meta-analyses of clinical trials investigating the efficacy and safety of paclitaxel-coated balloons (PCB) vs. conventional balloon angioplasty in arteriovenous fistulas (AVFs) and grafts stenosis. Medline (via PubMed) and SCOPUS databases were searched up to July 15th 2020. All meta-analyses that enrolled randomized controlled trials (RCTs) comparing PCB with plain balloons in AVFs and grafts were included. Re-analysis of original data was performed assessing predictive intervals (PI). Quality of the included meta-analyses was assessed using AMSTAR score. Eight meta-analyses were included and four clinical outcomes [target lesion primary patency (TLPP), circuit primary patency, mortality, complication rate] derived from 14 RCTs, were analyzed. There were no significant differences in the TLPP in meta-analyses providing data purely from autologous AVFs. Significant benefits regarding TLPP and circuit primary patency at 3, 6, and 12-months in favor of PCB were reported in four meta-analyses mixing AVFs and grafts; however when PI were assessed, in all but one meta-analysis these included the null value, indicating no significant benefit. In only one meta-analysis significant difference of TLPP at 12-months in favor of PCB was noticed. (Odds Ratio 0.0009 PI: 0.28-0.85) No mortality difference was noticed in four meta-analyses providing data up to 24 months. In conclusion this overview revealed a modest benefit of using PCB angioplasty compared to plain angioplasty in AVFs and graft stenosis. No increased mortality was noticed in the PCB group.
引用
收藏
页码:981 / 988
页数:8
相关论文
共 50 条
  • [11] Paclitaxel-Coated Balloon versus Plain Balloon Angioplasty for Dysfunctional Autogenous Radiocephalic Arteriovenous Fistulas: A Prospective Randomized Controlled Trial
    Kim, Jong Woo
    Kim, Jeong Ho
    Byun, Sung Su
    Kang, Jin Mo
    Shin, Ji Hoon
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (11) : 1239 - 1247
  • [12] Early Experience With Paclitaxel-Coated Balloon Angioplasty for Treatment of Autogenous Hemodialysis Fistula Outflow Stenosis
    Kabutey, Nii-Kabu
    Chen, Samuel L.
    Jia, Jemianne J.
    Kuo, Isabella J.
    Fujitani, Roy M.
    JOURNAL OF VASCULAR SURGERY, 2016, 63 (06) : 96S - 96S
  • [13] Paclitaxel-Coated Balloon Versus Plain Balloon Angioplasty for Hemodialysis Access Maintenance: A Systematic Review and Updated Meta-analysis
    Chen, Xiyang
    Liu, Yang
    Wang, Jiarong
    Zhao, Jichun
    Singh, Niten
    Zhang, Wayne
    JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : E14 - E15
  • [14] PACLITAXEL-COATED BALLOON ANGIOPLASTY FOR STENOSIS OF ARTERIOVENOUS FISTULA IN PATIENTS UNDER HEMODIALYSIS: 18TH MONTH FOLLOW-UP
    Griveas, Ioannis
    Vourliotakis, Georgios
    Kandounakis, Ioannis
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2020, 35 : 1677 - 1677
  • [15] Angioplasty of Dysfunctional Dialysis Fistula or Graft with Resveratrol-Excipient and Paclitaxel-Coated Balloon Improves Primary Patency Rates Compared to Plain Angioplasty Alone
    Novak, Matej
    Matras, Patrik
    Kavan, Jan
    Lambert, Lukas
    Burgetova, Andrea
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [16] Paclitaxel-Coated versus Plain Balloon Angioplasty for Dysfunctional Arteriovenous Fistulae: One-Year Results of a Prospective Randomized Controlled Trial
    Kitrou, Panagiotis M.
    Spiliopoulos, Stavros
    Katsanos, Konstantinos
    Papachristou, Evangelos
    Siablis, Dimitris
    Karnabatidis, Dimitris
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (03) : 348 - 354
  • [17] Comparison of drug-coated balloon angioplasty versus common balloon angioplasty for arteriovenous fistula stenosis: A systematic review and meta-analysis
    Zhang, Yong
    Yuan, Fan-Li
    Hu, Xiang-Yang
    Wang, Qi-Bing
    Zou, Zhen-Wu
    Li, Zhen-Guo
    CLINICAL CARDIOLOGY, 2023, 46 (08) : 877 - 885
  • [18] Balloon angioplasty for arteriovenous graft stenosis
    Anain, P
    Shenoy, S
    O'Brien-Irr, M
    Harris, LM
    Dryjski, M
    JOURNAL OF ENDOVASCULAR THERAPY, 2001, 8 (02) : 167 - 172
  • [19] Comparison of drug-coated balloon angioplasty versus conventional angioplasty for arteriovenous fistula stenosis: Systematic review and meta-analysis
    Salim, Sohail Abdul
    Tran, Hong
    Thongprayoon, Charat
    Fulop, Tibor
    Cheungpasitporn, Wisit
    JOURNAL OF VASCULAR ACCESS, 2020, 21 (03): : 357 - 365
  • [20] Comparison of Paclitaxel-Coated Balloon Treatment and Plain Old Balloon Angioplasty for De Novo Coronary Lesions
    Her, Ae-Young
    Ann, Soe Hee
    Singh, Gillian Balbir
    Kim, Yong Hoon
    Yoo, Sang-Yong
    Garg, Scot
    Koo, Bon-Kwon
    Shin, Eun-Seok
    YONSEI MEDICAL JOURNAL, 2016, 57 (02) : 337 - 341