Use of high performance liquid chromatography-electrospray ionization-tandem mass spectrometry for the analysis of ceramide-1-phosphate levels

被引:72
|
作者
Wijesinghe, Dayanjan S. [1 ]
Allegood, Jeremy C. [1 ]
Gentile, Luciana B. [1 ]
Fox, Todd E. [2 ]
Kester, Mark [2 ]
Chalfant, Charles E. [1 ,3 ,4 ]
机构
[1] Virginia Commonwealth Univ, Sch Med, Dept Biochem & Mol Biol, Richmond, VA 23298 USA
[2] Penn State Coll Med, Dept Pharmacol, Hershey, PA 17033 USA
[3] Hunter Holmes McGuire Vet Adm Med Ctr, Res & Dev, Richmond, VA 23249 USA
[4] Massey Canc Ctr, Richmond, VA 23298 USA
基金
美国国家卫生研究院;
关键词
lipidomics; mass spectrometry; ceramide kinase; ceramide transport protein; prostaglandins; phospholipase A(2); inflammation; arachidonic acid; dodecane; eicosanoids; CERAMIDE KINASE; QUANTITATIVE-ANALYSIS; BIOLOGICAL SAMPLES; DEFICIENT MICE; 1-PHOSPHATE; EXTRACTS; SPHINGOMYELIN; CELLS;
D O I
10.1194/jlr.D000430
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Ceramide-1-phosphate (C1P) is a bioactive sphingolipid with roles in several biological processes. Currently, high performance liquid chromatography-electrospray ionization-tandem mass spectrometry ( HPLC ESI-MS/MS) offers the most efficient method of quantifying C1P. However, the published protocols have several drawbacks causing overestimations and carryovers. Here, the reported overestimation of C1P was shown to be due to incomplete neutralization of base hydrolyzed lipid extracts leading to the hydrolysis of SM to C1P. Actual quantity of C1P in cells (6 pmols/10(6) cells) was much lower than previously reported. Also, the major species of C1P produced by ceramide kinase (CERK) was found to be d(18:1/16:0) with a minority of d(18:1/24:1) and d(18:1/24:0). The artifactual production of C1P from SM was used for generating C1Ps as retention time markers. Elimination of carryovers between samples and a 2-fold enhancement in the signal strength was achieved by heating the chromatographic column to 60 degrees C. The role of ceramide transport protein (CERT) in supplying substrate to CERK was also revalidated using this new assay. Finally, our results demonstrate the presence of additional pathway(s) for generation of the C1P subspecies, d(18:1/18:0) C1P, as well as a significant portion of d(18:1/16:0), d(18:1/24:1), and d(18:1/24:0). In conclusion, this study introduces a much improved and validated method for detection of C1P by mass spectrometry and demonstrates specific changes in the C1P subspecies profiles upon downregulation of CERK and CERT.-Wijesinghe, D. S., J. C. Allegood, L. B. Gentile, T. E. Fox, M. Kester, and C. E. Chalfant. Use of high performance liquid chromatography-electrospray ionization-tandem mass spectrometry for the analysis of ceramide-1-phosphate levels. J. Lipid Res. 2010. 51: 641-651.
引用
下载
收藏
页码:641 / 651
页数:11
相关论文
共 50 条
  • [41] Hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry of a complex mixture of native and oxidized phospholipids
    Losito, I.
    Facchini, L.
    Diomede, S.
    Conte, E.
    Megli, F. M.
    Cataldi, T. R. I.
    Palmisano, F.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1422 : 194 - 205
  • [42] Identification and Quantification of the Major Constituents in Egyptian Carob Extract by Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Owis, Asmaa Ibrahim
    El-Naggar, El-Motaz Bellah
    PHARMACOGNOSY MAGAZINE, 2016, 12 (45) : S1 - S6
  • [43] Determination of pharmaceuticals from different therapeutic classes in wastewaters by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Botitsi, Eleni
    Frosyni, Charalampia
    Tsipi, Despina
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) : 1317 - 1327
  • [44] Determination of several aminoglycoside and macrolide antibiotics in animal tissues by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Font, Guillermina
    Berrada, Houda
    Ferrer, Emilia
    Manes, Jordi
    TOXICOLOGY LETTERS, 2008, 180 : S66 - S66
  • [45] Structural elucidation of dipeptides displaying limited mass spectral information by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Madmon, Moran
    Weissberg, Avi
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (09):
  • [46] Liquid chromatography-electrospray ionization-tandem mass spectrometry method for the determination of epoxidized soybean oil in food products
    Suman, M
    La Tegola, S
    Catellani, D
    Bersellini, U
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (26) : 9879 - 9884
  • [47] Determination of naturally occurring progestogens in bovine milk as their oxime derivatives using high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Regal, Patricia
    Nebot, Carolina
    Vazquez, Beatriz I.
    Cepeda, Alberto
    Fente, Cristina
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2010, 90 (10) : 1621 - 1627
  • [48] Fast and sensitive determination of 10 forbidden phthalates in perfumes by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Wei, Xue-Bing
    Li, Ruo-Qi
    Yu, Han
    Wang, Ren-Qi
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1578 : 45 - 52
  • [49] Characterization of glycerophospholipid molecular species in six species of edible clams by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Liu, Zhong-Yuan
    Zhou, Da -Yong
    Zhao, Qi
    Yin, Fa-Wen
    Hu, Xiao-Pei
    Song, Liang
    Qin, Lei
    Zhang, Jian-Run
    Zhu, Bei-Wei
    Shahidi, Fereidoon
    FOOD CHEMISTRY, 2017, 219 : 419 - 427
  • [50] Identification of glycerophospholipid molecular species of mussel (Mytilus edulis) lipids by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Yin, Fa-Wen
    Zhou, Da-Yong
    Zhao, Qi
    Liu, Zhong-Yuan
    Hu, Xiao-Pei
    Liu, Yan-Fei
    Song, Liang
    Zhou, Xin
    Qin, Lei
    Zhu, Bei-Wei
    Shahidi, Fereidoon
    FOOD CHEMISTRY, 2016, 213 : 344 - 351