Use of high performance liquid chromatography-electrospray ionization-tandem mass spectrometry for the analysis of ceramide-1-phosphate levels

被引:72
|
作者
Wijesinghe, Dayanjan S. [1 ]
Allegood, Jeremy C. [1 ]
Gentile, Luciana B. [1 ]
Fox, Todd E. [2 ]
Kester, Mark [2 ]
Chalfant, Charles E. [1 ,3 ,4 ]
机构
[1] Virginia Commonwealth Univ, Sch Med, Dept Biochem & Mol Biol, Richmond, VA 23298 USA
[2] Penn State Coll Med, Dept Pharmacol, Hershey, PA 17033 USA
[3] Hunter Holmes McGuire Vet Adm Med Ctr, Res & Dev, Richmond, VA 23249 USA
[4] Massey Canc Ctr, Richmond, VA 23298 USA
基金
美国国家卫生研究院;
关键词
lipidomics; mass spectrometry; ceramide kinase; ceramide transport protein; prostaglandins; phospholipase A(2); inflammation; arachidonic acid; dodecane; eicosanoids; CERAMIDE KINASE; QUANTITATIVE-ANALYSIS; BIOLOGICAL SAMPLES; DEFICIENT MICE; 1-PHOSPHATE; EXTRACTS; SPHINGOMYELIN; CELLS;
D O I
10.1194/jlr.D000430
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Ceramide-1-phosphate (C1P) is a bioactive sphingolipid with roles in several biological processes. Currently, high performance liquid chromatography-electrospray ionization-tandem mass spectrometry ( HPLC ESI-MS/MS) offers the most efficient method of quantifying C1P. However, the published protocols have several drawbacks causing overestimations and carryovers. Here, the reported overestimation of C1P was shown to be due to incomplete neutralization of base hydrolyzed lipid extracts leading to the hydrolysis of SM to C1P. Actual quantity of C1P in cells (6 pmols/10(6) cells) was much lower than previously reported. Also, the major species of C1P produced by ceramide kinase (CERK) was found to be d(18:1/16:0) with a minority of d(18:1/24:1) and d(18:1/24:0). The artifactual production of C1P from SM was used for generating C1Ps as retention time markers. Elimination of carryovers between samples and a 2-fold enhancement in the signal strength was achieved by heating the chromatographic column to 60 degrees C. The role of ceramide transport protein (CERT) in supplying substrate to CERK was also revalidated using this new assay. Finally, our results demonstrate the presence of additional pathway(s) for generation of the C1P subspecies, d(18:1/18:0) C1P, as well as a significant portion of d(18:1/16:0), d(18:1/24:1), and d(18:1/24:0). In conclusion, this study introduces a much improved and validated method for detection of C1P by mass spectrometry and demonstrates specific changes in the C1P subspecies profiles upon downregulation of CERK and CERT.-Wijesinghe, D. S., J. C. Allegood, L. B. Gentile, T. E. Fox, M. Kester, and C. E. Chalfant. Use of high performance liquid chromatography-electrospray ionization-tandem mass spectrometry for the analysis of ceramide-1-phosphate levels. J. Lipid Res. 2010. 51: 641-651.
引用
收藏
页码:641 / 651
页数:11
相关论文
共 50 条
  • [2] Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Fang, WB
    Andrenyak, DM
    Moody, DE
    Nuwayser, ES
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (03) : 169 - 174
  • [3] Regiospecific Analysis of Triacylglycerols by Ultrahigh-Performance-Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Tarvainen, Marko
    Kallio, Heikki
    Yang, Baoru
    [J]. ANALYTICAL CHEMISTRY, 2019, 91 (21) : 13695 - 13702
  • [4] Determination of Naloxone and Nornaloxone (Noroxymorphone) by High-Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry
    Fang, Wenfang B.
    Chang, Yan
    McCance-Katz, Elinore F.
    Moody, David E.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (08) : 409 - 417
  • [5] Analysis of testosterone and dihydrotestosterone in mouse tissues by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Weng, Yan
    Xie, Fang
    Xu, Li
    Zagorevski, Dmitri
    Spink, David C.
    Ding, Xinxin
    [J]. ANALYTICAL BIOCHEMISTRY, 2010, 402 (02) : 121 - 128
  • [6] Determination of cymipristone in human plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Yuan, Hong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 719 - 723
  • [7] Characteristic fingerprint analysis of Dendrobium huoshanense by ultra-high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Wu, Chengfeng
    Gui, Shuhua
    Huang, Yuechun
    Dai, Yafeng
    Shun, Qingsheng
    Huang, Kaiwei
    Tao, Shengchang
    Wei, Gang
    [J]. ANALYTICAL METHODS, 2016, 8 (18) : 3802 - 3808
  • [8] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    [J]. ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [9] Identification and quantification of glucosamine in rabbit cartilage and correlation with plasma levels by high performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Pastorini, Elisabetta
    Vecchiotti, Stefania
    Colliva, Carolina
    Persiani, Stefano
    Rotini, Roberto
    Roatti, Giulia
    Zaccarelli, Lorenzo
    Rovati, Lucio Claudio
    Roda, Aldo
    [J]. ANALYTICA CHIMICA ACTA, 2011, 695 (1-2) : 77 - 83
  • [10] A liquid chromatography-electrospray ionization-tandem mass spectrometry study of ethanolamines in high salinity industrial wastewaters
    Campo, Pablo
    Suidan, Makram T.
    Chai, Yunzhou
    Davis, John
    [J]. TALANTA, 2010, 80 (03) : 1110 - 1115