Study of the response of silicon detectors for alpha particles

被引:12
|
作者
Chambaudet, A [1 ]
Klein, D
Voytchev, M
机构
[1] Univ Franche Comte, Lab Microanal Nucl, F-25030 Besancon, France
[2] Univ Franche Comte, Inst Sci & Tech Environm, Lab Metrol Interfaces Tech & Antenne Nord Franche, F-25211 Montbeliard, France
[3] Bulgarian Acad Sci, Inst Nucl Res & Nucl Energy, BU-1784 Sofia, Bulgaria
关键词
silicon detector; radon; thoron; radon monitoring; alpha spectrum;
D O I
10.1016/S1350-4487(97)00053-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Numerous radon measurements are carried out using silicon detectors directly in the environment. This new kind of alpha radiation measurement has been developed because the reduced cost makes it possible to replace the usual plastic track detectors. At our laboratory, an alpha particle detector has been designed from a commercial silicon photodiode. This type of detector can determine the device response perfectly in any kind of environment. Different spectrum analyses have been conducted in the laboratory and field to define the exact origin of counted alpha particles. We studied the response for different radon and thoron concentration levels and observed the energy of the detected alpha particles. We carried out some of these experiments with gas flux, and some without, to show the effects of interactions with surfaces to obtain thermodynamic equilibrium in the detection chamber. Finally, the silicon diodes that we tested measure the alpha particles of the decay products (polonium) from the radon and the thoron, but very weakly from the gases themselves. Thus, it is possible to make mistakes when measuring the radon if the count of alpha particles is performed without spectrum analysis. One reason for this is that the decay progenies of the radon are solid radio-elements with thermodynamic proprieties different from gases.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 50 条
  • [41] Hydrogenated amorphous silicon pixel detectors for minimum ionizing particles
    Perez-Mendez, V.
    Kaplan, S.N.
    Cho, G.
    Fujieda, I.
    Qureshi, S.
    Ward, W.
    Nuclear instruments and methods in physics research, 1988, 273 (01): : 127 - 134
  • [42] DETECTION OF LOW ENERGY HEAVY PARTICLES WITH SILICON BARRIER DETECTORS
    RAY, JA
    BARNETT, CF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1969, NS16 (01) : 82 - +
  • [43] Usability of diamond detectors for spectrometric measurements of lost alpha particles
    Drozdowicz, K.
    Dankowski, J.
    Gabanska, B.
    Igielski, A.
    Kurowski, A.
    Marczewska, B.
    Nowak, T.
    Wodniak, I.
    Woznicka, U.
    DIAMOND AND RELATED MATERIALS, 2011, 20 (5-6) : 743 - 745
  • [44] Comparative study of silicon detectors.
    Allier, CP
    Valk, H
    Huizenga, J
    Bom, VR
    Hollander, RW
    Eijk, CWE
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 799 - 803
  • [45] EVOLUTION OF ALPHA-PARTICLE TRACKS IN SILICON STRIP DETECTORS
    ROSENFELD, AB
    LITOVCHENKO, PG
    PUGATCH, VM
    ZINETS, OS
    BARABASH, LI
    PAVLENKO, YN
    VASILYEV, YO
    NEMETS, OF
    MARUSAN, IA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 947 - 950
  • [46] SILICON SURFACE-BARRIER ALPHA-PARTICLE DETECTORS
    MEDNIKOV, AK
    BABUSHKI.AA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (03): : 545 - &
  • [47] The effects of intense gamma-irradiation on the alpha-particle response of silicon carbide semiconductor radiation detectors
    Ruddy, Frank H.
    Seidel, John G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 163 - 168
  • [48] RESPONSE OF SILICON SURFACE BARRIER DETECTORS TO HEAVY IONS
    KARCHER, T
    WOTHERSPOON, N
    NUCLEAR INSTRUMENTS & METHODS, 1971, 93 (03): : 519 - +
  • [49] The spectral response of silicon X-ray detectors
    Eggert, T.
    Boslau, O.
    Kemmer, J.
    Pahke, A.
    Wiest, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01): : 1 - 11
  • [50] Studies on the Response of Double Sided Silicon Strip Detectors
    Torresi, D.
    Stanko, D.
    Di Pietro, A.
    Figuera, P.
    Fisichella, M.
    Lattuada, M.
    Milin, M.
    Musumarra, A.
    Pellegriti, M. G.
    Scuderi, V.
    Strano, E.
    Zadro, M.
    NUCLEAR STRUCTURE AND DYNAMICS '12, 2012, 1491 : 89 - 92