Effects of immersion water temperature on whole-body fluid distribution in humans

被引:44
|
作者
Stocks, JM
Patterson, MJ
Hyde, DE
Jenkins, AB
Mittleman, KD
Taylor, NAS [1 ]
机构
[1] Univ Wollongong, Dept Biomed Sci, Wollongong, NSW 2522, Australia
[2] USN, Expt Diving Unit, Panama City, FL USA
[3] DesignWrite, Princeton, NJ USA
来源
ACTA PHYSIOLOGICA SCANDINAVICA | 2004年 / 182卷 / 01期
关键词
atrial natriuretic peptide; body fluid regulation; cold-water immersion; intracellular fluid; plasma volume;
D O I
10.1111/j.1365-201X.2004.01302.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aim: In this study, we quantified acute changes in the intracellular and extracellular fluid compartments during upright neutral- and cold-water immersion. We hypothesized that, during short-term cold immersion, fluid shifts would be wholly restricted to the extracellular space. Methods: Seven males were immersed 30 days apart: control (33.3 degrees SD 0.6 degreesC); and cold (18.1 degrees SD 0.3 degreesC). Posture was controlled for 4 h prior to a 60-min seated immersion. Results: Significant reductions in terminal oesophageal (36.9 degrees +/- 0.1 degrees-36.3 degrees +/- 0.1 degreesC) and mean skin temperatures (30.3 degrees +/- 0.3 degrees-23.0 degrees +/- 0.3 degreesC) were observed during the cold, but not the control immersion. Both immersions elicited a reduction in intracellular fluid [20.17 +/- 6.02 mL kg(-1) (control) vs. 22.72 +/- 9.90 mL kg(-1)], while total body water (TBW) remained stable. However, significant plasma volume (PV) divergence was apparent between the trials at 60 min [12.5 +/- 1.0% (control) vs. 6.1 +/- 3.1%; P < 0.05], along with a significant haemodilution in the control state (P < 0.05). Plasma atrial natriuretic peptide concentration increased from 18.0 +/- 1.6 to 58.7 +/- 15.1 ng L-1 (P < 0.05) during cold immersion, consistent with its role in PV regulation. We observed that, regardless of the direction of the PV change, both upright immersions elicited reductions in intracellular fluid. Conclusion: These observations have two implications. First, one cannot assume that PV changes reflect those of the entire extracellular compartment. Second, since immersion also increases interstitial fluid pressure, fluid leaving the interstitium must have been rapidly replaced by intracellular water.
引用
收藏
页码:3 / 10
页数:8
相关论文
共 50 条
  • [41] Heat Acclimation By Warm-water Immersion Enhances Whole-body Heat Loss In Older Adults
    Janetos, Kristina-Marie T.
    O'Connor, Fergus K.
    Richards, Brodie J.
    Koetje, Nicholas J.
    McCormic, James J.
    Flouris, Andreas D.
    Kenny, Glen P.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 1044 - 1044
  • [42] Whole-body vibration transmissibility in supine humans: Effects of board litter and neck collar
    Meusch, John
    Rahmatalla, Salam
    APPLIED ERGONOMICS, 2014, 45 (03) : 677 - 685
  • [43] DISTRIBUTION OF BURIMAMIDE STUDIED BY WHOLE-BODY AUTORADIOGRAPHY
    CROSS, SAM
    BLACK, M
    JOURNAL OF ANATOMY, 1973, 115 (MAY) : 143 - 143
  • [44] INVESTIGATIONS ON DISTRIBUTION OF RADIOPHARMACEUTICALS IN WHOLE-BODY SCINTIGRAM
    ANGER, K
    FEINE, U
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1973, : 187 - 188
  • [45] Thermoregulation and thermal sensation during whole-body water immersion at different water temperatures in healthy individuals: A scoping review
    Ntoumani, Maria
    Dugue, Benoit
    Rivas, Eric
    Gongaki, Konstantina
    JOURNAL OF THERMAL BIOLOGY, 2023, 112
  • [46] Effect of water temperature during whole body immersion on hydromineral homeostasis and energy metabolism
    Jimenez, C.
    Regnard, J.
    Robinet, C.
    Mourot, L.
    Gomez-Merino, D.
    Chennaoui, M.
    Jammes, Y.
    Desruelle, A-V
    Melin, B.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2010, 24 : 44 - 44
  • [47] Modelling of the skin temperature of whole-body cryotherapy
    Marreiro, A.
    Filliard, J. R.
    Pron, H.
    Beaumont, F.
    Polidori, G.
    Taiar, R.
    SCIENCE & SPORTS, 2017, 32 (05) : 316 - 319
  • [48] NASAL REACTION TO CHANGES IN WHOLE-BODY TEMPERATURE
    LUNDQVIST, GR
    PEDERSEN, OF
    HILBERG, O
    NIELSEN, B
    ACTA OTO-LARYNGOLOGICA, 1993, 113 (06) : 783 - 788
  • [49] WHOLE-BODY HYPERTHERMIA USING A WATER CIRCULATOR
    LOSHEK, DD
    GREENLAW, RH
    DOYLE, LA
    STRAHLENTHERAPIE, 1981, 157 (09) : 620 - 621
  • [50] PHYSIOLOGICAL RESPONSES OF HUMANS TO WHOLE-BODY LOW AMPLITUDE VIBRATION
    MORI, K
    KATO, J
    KAKIZAKI, T
    SUDO, A
    JAPANESE JOURNAL OF INDUSTRIAL HEALTH, 1973, 15 (06): : 654 - 655