Non-Invasive Detection of Mechanical Alternans Utilizing Photoplethysmography

被引:7
|
作者
Besleaga, Tudor [1 ]
Badiani, Sveeta [2 ]
Lloyd, Guy [2 ]
Toschi, Nicola [3 ,4 ,5 ]
Canichella, Antonio [3 ]
Demosthenous, Andreas [6 ]
Lambiase, Pier David [7 ]
Orini, Michele [7 ,8 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London WC1E 6BT, England
[2] St Bartholomews Hosp, Barts Heart Ctr, Echocardiog Lab, London EC1A 7BE, England
[3] Univ Roma Tor Vergata, Dept Biomed & Prevent, Med Phys Sect, I-00133 Rome, Italy
[4] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[5] Harvard Med Sch, Charlestown, MA 02129 USA
[6] UCL, Dept Elect & Elect Engn, London WC1E 7JE, England
[7] St Bartholomews Hosp, Barts Heart Ctr, Electrophysiol Dept, London EC1A 7BE, England
[8] UCL, Dept Mech Engn, London WC1E 6BT, England
关键词
Blood pressure (BP); cardiac alternans; hemodynamic instabilities; mechanical alternans (MA); photoplethysmography (PPG); PULSE-RATE VARIABILITY; CARDIAC ALTERNANS; PRESSURE; WAVE;
D O I
10.1109/JBHI.2018.2882550
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background and Significance: Mechanical alternans (MA) is a biomarker associated with mortality and life-threatening arrhythmias in heart failure patients. Despite showing prognostic value, its use is limited by the requirement of measuring the continuous blood pressure (BP), which is costly and impractical. Objective: To develop and test, for the first time, non-invasive MA surrogates based on photoplethysmography (PPG). Methods: Continuous BP and PPG were recorded during clinical procedures and tests in 35 patients. MA was induced either by ventricular pacing (Group A, N = 19) or exercise (Group B, N = 16). MA was categorized as sustained or intermittent if MA episodes were observed in at least 20 or between 12 and 20 consecutive beats, respectively. Eight features characterizing the pulse morphology were derived from the PPG, and MA surrogates were evaluated. Results: Sustained alternans was observed in 9 patients (47%) from Group A, whereas intermittent alternans was observed in 13 patients (68%) from Group A and in 10 patients (63%) from Group B. The PPG-based MA surrogate showing the highest accuracy, V-M, was based on the maximum of the first derivative of the PPG pulse. It detected both sustained and intermittent MA with 100% sensitivity and 100% specificity in Group A and intermittent MA with 100% sensitivity and 83% specificity in Group B. Furthermore, the magnitudes of MA and its PPG-based surrogate were linearly correlated (R-2 = 0.83, p < 0.001). Conclusion: MA can be accurately identified non-invasively through PPG analysis. This may have important clinical implications for risk stratification and remote monitoring.
引用
下载
收藏
页码:2409 / 2416
页数:8
相关论文
共 50 条
  • [31] NON-INVASIVE MAGNETIC DETECTION OF CARDIAC MECHANICAL-ACTIVITY - EXPERIMENTS
    WIKSWO, JP
    OPFER, JE
    FAIRBANK, WM
    MEDICAL PHYSICS, 1980, 7 (04) : 307 - 314
  • [32] NON-INVASIVE MAGNETIC DETECTION OF CARDIAC MECHANICAL-ACTIVITY - THEORY
    WIKSWO, JP
    MEDICAL PHYSICS, 1980, 7 (04) : 297 - 306
  • [33] Non-invasive mechanical ventilation in emergencies
    Lista, Eva
    Jacob, Javier
    Perez Mas, Juan Ramon
    Bardes, Ignasi
    MEDICINA CLINICA, 2012, 139 (09): : 414 - 414
  • [34] Non-Invasive Mechanical Ventilation in Neonatology
    Barbosa, Arnaldo Prata
    Jornada Krebs, Vera Lucia
    de Figueiredo, Miriam Perez
    CURRENT RESPIRATORY MEDICINE REVIEWS, 2012, 8 (01) : 3 - 11
  • [35] Non-invasive, Mechanical Treatment for Atherosclerosis
    Urso, Justin
    Narasimhulu, Chandrakala
    Parthasarathy, Sampath
    Kassab, Alain
    Vasu, Subith
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2018, 38
  • [36] Non-invasive mechanical ventilation in COPD
    Funk, G. -C.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2012, 107 (03) : 185 - 191
  • [37] Potential of advanced photoplethysmography sensing for non-invasive vascular diagnostics and early screening
    Spigulis, J
    Kukulis, I
    Fridenberga, E
    Venckus, G
    CLINICAL DIAGNOSTIC SYSTEMS: TECHNOLOGIES AND INSTRUMENTATION, 2002, 4625 : 38 - 43
  • [38] Bilateral study on arterial stiffness assessment by a non-invasive optical technique of Photoplethysmography
    Vassilenko, V.
    Silva, A. C.
    Martin, A. M.
    O'Neill, J. G.
    TECHNOLOGY AND MEDICAL SCIENCES - TMSI 2010, 2011, : 349 - 350
  • [39] Non-invasive monitoring of muscle blood perfusion by photoplethysmography: evaluation of a new application
    Sandberg, M
    Zhang, Q
    Styf, J
    Gerdle, B
    Lindberg, LG
    ACTA PHYSIOLOGICA SCANDINAVICA, 2005, 183 (04): : 335 - 343
  • [40] Arterial stiffness indices in healthy volunteers using non-invasive digital photoplethysmography
    Brillante, Divina G.
    O'Sullivan, Anthony J.
    Howes, Laurence G.
    BLOOD PRESSURE, 2008, 17 (02) : 116 - 123