Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance

被引:26
|
作者
Houriez-Gombaud-Saintonge, Sophia [1 ,2 ,3 ]
Mousseaux, Elie [4 ]
Bargiotas, Ioannis [5 ]
De Cesare, Alain [1 ,3 ]
Dietenbeck, Thomas [1 ,3 ]
Bouaou, Kevin [1 ,3 ]
Redheuil, Alban [1 ,3 ]
Soulat, Gilles [4 ]
Giron, Alain [1 ]
Gencer, Umit [4 ]
Craiem, Damian [6 ]
Messas, Emmanuel [4 ]
Bollache, Emilie [1 ,3 ]
Chenoune, Yasmina [2 ]
Kachenoura, Nadjia [1 ,3 ]
机构
[1] Sorbonne Univ, INSERM, CNRS, LIB, F-75006 Paris, France
[2] ESME Sudria Res Lab, Paris, France
[3] ICAN, Paris, France
[4] Hop Europeen Georges Pompidou, Paris, France
[5] Univ Paris Saclay, CMLA, ENS Cachan, CNRS, F-94235 Cachan, France
[6] Univ Favaloro, CONICET, IMeTTyB, Buenos Aires, DF, Argentina
关键词
Pulse wave velocity; 4D flow CMR; Aortic stiffness; Aging; ARTERIAL STIFFNESS; TRANSIT-TIME; MRI; PRESSURE; AGE; REPRODUCIBILITY; REFLECTION; VALIDATION; MORTALITY; 2D;
D O I
10.1186/s12968-019-0584-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. Methods We studied 47 healthy subjects (49.5 +/- 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. Results 4D flow CMR aoPWV estimates were significantly (p < 0.05) correlated to the CMR-independent Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with the strongest correlations for the 3D-like strategy using wavelets TT (S2-TTw) (R = 0.62, 0.65, 0.77 and 0.52, respectively, all p < 0.001). S2-TTw was also highly reproducible (ICC = 0.99, BA = 0.09 m/s) and robust to lower temporal resolution (ICC = 0.97, BA = 0.15 m/s). Conclusions Reproducible 4D flow CMR aoPWV estimates can be obtained using full 3D aortic coverage. Such 4D flow CMR stiffness measures were significantly associated with Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with a slight superiority of the 3D strategy using wavelets transit time (S2-TTw).
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Comparison of an oscillometric method with cardiac magnetic resonance for the analysis of aortic pulse wave velocity
    Feistritzer, H.
    Reinstadler, S.
    Klug, G.
    Franz, W.
    Metzler, B.
    WIENER KLINISCHE WOCHENSCHRIFT, 2014, 126 (17-18) : 576 - 576
  • [22] Comparison of an Oscillometric Method with Cardiac Magnetic Resonance for the Analysis of Aortic Pulse Wave Velocity
    Feistritzer, H. -J.
    Reinstadler, S. J.
    Klug, G.
    Kremser, C.
    Schocke, M.
    Franz, W. M.
    Metzler, B.
    WIENER KLINISCHE WOCHENSCHRIFT, 2014, 126 : S116 - S116
  • [23] Comparison of an Oscillometric Method with Cardiac Magnetic Resonance for the Analysis of Aortic Pulse Wave Velocity
    Feistritzer, Hans-Josef
    Reinstadler, Sebastian J.
    Klug, Gert
    Kremser, Christian
    Seidner, Benjamin
    Esterhammer, Regina
    Schocke, Michael F.
    Franz, Wolfgang-Michael
    Metzler, Bernhard
    PLOS ONE, 2015, 10 (01):
  • [24] 2127 Validation of cardiovascular magnetic resonance aortic distensibility with applanation tonometry pulse wave velocity
    Adam J Nelson
    Angelo Carbone
    Stephen G Worthley
    Cynthia Piantadosi
    Sarah A Hope
    James D Cameron
    Ian T Meredith
    Matthew I Worthley
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [25] Feasibility of Wave Intensity Analysis from 4D Cardiovascular Magnetic Resonance Imaging Data
    Sophocleous, Froso
    Delchev, Kiril
    De Garate, Estefania
    Hamilton, Mark C. K.
    Caputo, Massimo
    Bucciarelli-Ducci, Chiara
    Biglino, Giovanni
    BIOENGINEERING-BASEL, 2023, 10 (06):
  • [26] Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
    Harloff, Andreas
    Mirzaee, Hanieh
    Lodemann, Thomas
    Hagenlocher, Paul
    Wehrum, Thomas
    Stuplich, Judith
    Hennemuth, Anja
    Hennig, Juergen
    Grundmann, Sebastian
    Vach, Werner
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [27] Determination of aortic stiffness using 4D flow cardiovascular magnetic resonance - a population-based study
    Andreas Harloff
    Hanieh Mirzaee
    Thomas Lodemann
    Paul Hagenlocher
    Thomas Wehrum
    Judith Stuplich
    Anja Hennemuth
    Jürgen Hennig
    Sebastian Grundmann
    Werner Vach
    Journal of Cardiovascular Magnetic Resonance, 20
  • [28] Expanding the volume on 4D flow CMR Editorial for "Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve"
    Fischer, Kady
    Bastiaansen, Jessica A. M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025, 41 (02): : 181 - 183
  • [29] Assessing cerebral arterial pulse wave velocity using 4D flow MRI
    Bjornfot, Cecilia
    Garpebring, Anders
    Qvarlander, Sara
    Malm, Jan
    Eklund, Anders
    Wahlin, Anders
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2021, 41 (10): : 2769 - 2777
  • [30] Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
    Markl, Michael
    Kilner, Philip J.
    Ebbers, Tino
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13